HomeMy WebLinkAbout2034 LA PORTE RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/09/2025 08/12/2025 2026-00000009 $200.00 Customer #: 12855 HAMPTON INN 2034 LA PORTE RD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2034 LA PORTE RD - 6-23-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 3 $200.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 12855 07/09/2025 08/12/2025 2026-00000009 $200.00 Less Prepayment Total Due — > City of Waterloo $0.00 $200.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report_ ampton Inn & Suites - 2034 La Porte RD, BLDG 2034 La Porte Rd, Waterloo IA 50702 Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street Inspection Number 13671-R6 SUMMARY OF INSPECTION 0 0 0 3 Passed codes Resolved violations NEXT STEPS 0 15 Failed codes Please direct questions about your Inspection to: JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org, 3192301224 GE OT1a ES Brad Baldwin - 06/24/2025 @ 15:14 $200 Re -inspection fee for failure to correct violations on 6/23/25 JE - r5/22/2025 @ 13:49 Provide corrections to avoid re -inspection fees JEFF SIEBEL - 05/22/2025 @ 13:49 Annual inspection $235 JEFF SIEBEL - 05122/2025 @ 13:49 Provide corrections to avoid re -inspection fees. JEFF SIEBEL - 05/22/2025 @ 13:49 Re -inspection fee $100 JEFF SIEBEL - 05/22/2025 @ 13:49 Corrections not made on fire sprinkler, standpipe, or fire alarm and no date for completion of fire door certifications. JEFF SIEBEL - 05/22/2025 @ 13:49 Re -inspection fee $150 JEFF SIEBEL - 05/22/2025 @ 13:49 Called Mitch on 4/17/25 and he stated no improvement. JEFF SIEBEL - 05122/2025 @ 13:49 Re -inspection fee $200 JEFF SIEBEL - 05/22/2025 @ 13:49 annual inspection $200 Reinspection Date 07/22/2025 GENERATED ON 6/24/25, 3:22 PM 1 OF 8 JEFF SIEBEL - 0512212025 @ 13:49 We are recommending denial of alcohol license to the City Council because of lack of progress on required certification of guest room fire doors that were altered during construction. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Cayenne Adams - Manager CHECKLISTS Date: JEFF SIEBEL 06124/2025 GENERATED ON 6/24/25, 3:22 PM 2 OF 8 Reinspection Status Code Fail Fail Fail Fail 0 102.4 The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 5.2.1 Sprinklers shall be inspected at least annually by licensed contractor 5.2.1.1.5 Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall be replaced if found missing during the inspection. 704.1 Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floorlceiling assemblies and roof or rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Descriution Location: Entire buiding Comments: Obtain permits and inspections for all work concerning fire door repair, replacement smoke seals, all hardware replaced. Please see original attached email with codes concerning information requiered for fire door hardware. Please contact Building Official Greg Ahlhelm with questions. 319-291-4319 Location: Annual Standpipe insepction deficiencies Comments: Provide current annual fire sprinkler stand pipe inspection report wth all discrepancies corrected. Current report lists 2 discrepancies. Contractor must upload corrections online to the compliance engine. Location: Room 300 Comments: replace missing eschutcheon above sink Location: Entire second floor guest fire doors Comments: Install approved smoke seal in all fire door openings that has been removed including stair doors and utility areas. Check all other floors GENERATED ON 6/24/25, 3:22 PM 3 OF 8 Fail 704.1 Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 704.1 Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Guest Computer Room Comments: patch sheetrock ceiling with sheetrock. Mud and tape joints. Additional comments: Permit for patch of ceiling shall be obtained Location: Stairway Fire Door by room 330 Comments: Repair fire door. There is a gap at bottom of door. Must completely seal GENERATED ON 6/24/25, 3:22 PM 4 OF 8 Fail 704.1 Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Entire 4th Floor Fire Doors Comments: Repair or replace fire doors that are improperly installed. Doors must seal all sides including top and botom to prevent smokelfire from inflitrating fire rated coridoor. GENERATED ON 6/24125, 3:22 PM 5 OF 8 Fail Fail Fail Fail Fail 704.1 Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floorlceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 704.1 Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floorlceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 705.2.4 Swinging fire doors shall close from the full -open position and latch automatically. 705.2.4 Swinging fire doors shall close from the full -open position and latch automatically. 705.2.4 Swinging fire doors shall close from the full -open position and latch automatically. Location: obtain permit and inspections Location: Entire Second Floor Comments: verify all removed smoke seals have been replaced on second floor. Also 4th floor and all other smoke sweeps added to bottom of doors must be verified as listed for fire doors and inspected. Location: West 3rd floor storage room fire door Comments: repair door. Fire Door must completely self -close and latch Location: 3rd Floor West stair fire door Comments: Repair door. Fire door must completly self -close and latch. Location: 2nd Floor laundry inside door Comments: Repair fire door. Fire door must completely self -close and latch. Upper part of door does not properly seal. GENERATED ON 6/24/25, 3:22 PM 6 OF 8 Fail Fail Fail 705.2.4 Swinging fire doors shall close from the full -open position and latch automatically. 705.2.4 Swinging fire doors shall close from the full -open position and latch automatically. Chapter 14 Fire alarm system tested at least annually by licensed contractor Location: Room 202 Comments: repair door . Fire door must completely self -close and latch. Location: 2nd Floor East Electrical Room Comments: Repair door .Inside fire door must completly self -close and latch. Repair smoke seal Additional comments: Door to hallway failed to latch. Location: Annual Fire Alarm Inspection Comments: Provide current semi-annual fire alarm inspection report with all discrepancies corrected. Currently 106 days past due. Contractor must upload online to the compliance engine. GENERATED ON 6/24/25, 3:22 PM 7 OF 8 Statement of Fees FEE Invoice Date Inspection Fee N/A $200.00 Date Paid Amount Paid Invoice Number NIA Check Number N/A Transaction Number N/A GENERATED ON 6/24/25, 3:22 PM 8 OF 8