COMMERCIAL INSPECTION - 1512 FLAMMANG DR - 6-30-25
FOR BILLING INQUIRY: (319)291-4323
Description
INSPECTION 2,000
OCCUPANCY FEE
Total Price
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
11161
07/09/2025
08/12/2025
2026-00000010
$80.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Hy-Vee Gas #3 -1512 Flammang DR, BLDG 1512 Flammang Dr, Waterloo IA 50702
INSPECT
nspection Date
06/30/2025
DETAILS
( Inspection Type
Annual Inspection (1Yr)
Or
Brad Baldwin
\\\
Other Inspectors
NIA
425 E. 3rd Street
Inspection Number
14056
Shift Station Unit
NIA NIA NIA
SUMMARY OF INSPECTION
040 04 030
Passed codes Failed codes NIA codes
NEXT STEPS
Please direct questions about your Inspection to:
Brad Baldwin
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL
Brad Baldwin - 07/01/2025 @ 07:02
$80 annual inspection fee
Brad Baldwin - 07/0112025 @ 07:02
a€¢ Commercial Fire Inspector a€" brad.baldwin@waterloo-ia.org a€" Work: 319-291-4319 (#5) - Cell: 319-230-1224
Reinspection Date
0712412025
Brad Baldwin - 07/01/2025 @ 07:02
a€¢ Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
Brad Baldwin - 0710112025 @ 07:02
a€t If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday a€" Friday, 9:00 a.m. a€" 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Denise Greene
CHECKLISTS
Date: Brad Baldwin 07/01/2025
GENERATED ON 7/1/25, 7:21 AM
1 OF 4
Additional Codes
Status C, • a
Fail
5303.5.3
Compressed gas containers, cylinders and tanks shall be
secured to prevent falling caused by contact, vibration or
seismic activity. Securing of compressed gas containers,
cylinders and tanks shall be by one of the following methods:
1.Securing containers, cylinders and tanks to a fixed object
with one or more restraints. 2.Securing containers, cylinders
and tanks on a cart or other mobile device designed for the
movement of compressed gas containers, cylinders or tanks.
3, Nesting of compressed gas containers, cylinders and tanks
at container filling or servicing facilities or in sellersa€v`
warehouses not open to the public. Nesting shall be allowed
provided that the nested containers, cylinders or tanks, if
dislodged, do not obstruct the required means of egress.
4.Securing of compressed gas containers, cylinders and
tanks to or within a rack, framework, cabinet or similar
assembly designed for such use. Exception: Compressed gas
containers, cylinders and tanks in the process of
examination, filling, transport or servicing.
Des ;rip on
Location: Cooler
Comments: Secure compressed gas cylinders with chain to avoid tip
over.
GENERATED ON 7/1/25, 7:21 AM
2 OF 4
Electrical Safety
Statu;
Fail
0
Fail
Fail
603.2.2
Open junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
603.4
A working space of not Working space around electrical
equipment shall be provided in accordance with Section
110.26 of NFPA 70 for electrical equipment rated 1,000 volts or
less, and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts. The minimum required working space
shall be not Tess than 30 inches (762 mm) in width, 36 inches
(914 mm) in depth and 78 inches (1981 mm) in height shall be
providedin front of electrical service equipment. Where the
electrical service equipment is wider than 30 inches (762
mm), the minimum working space shall be not less than the
width of the equipment. Storage of materials shall not be
located within the designated working space. Exceptions: 1.
Where other dimensions are required or allowed by NFPA 70.
2. Access openings into attics or under -floor areas that
provide a minimum clear opening of 22 inches (559 mm) by 30
inches (762 mm).
603.5.3
Relocatable power tap cords shall not extend through walls,
ceilings, floors, under doors or floor coverings, or be subject
to environmental or physical damage.
Location: Coolers
Comments: Provide moisture proof covers for light fixtures in cooler.
Location: Storage room
Comments: Clear obstructions within 36" in front of electrical panels.
Current work in men's bathroom, staff using area to store materials
during work.
I MAINTAIN $"
CLEARANCE RI
ELEECTRIICAL
Location: Storage room
Comments: Properly hang or support power strip behind printer to
avoid hanging from wires.