Loading...
HomeMy WebLinkAbout407 E PARK AVECustomer #: 9492 ELK'S CLUB 407 E PARK AV WATERLOO, IA 50703 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/09/2025 08/12/2025 2026-00000006 $100.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 407 E PARK AVE - 6-17-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 20,000 OCCUPANCY FEE Total Price $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 9492 07/09/2025 08/12/2025 2026-00000006 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue „ins peetio -Repo Elk's Club - 407 E Park AVE, BLDt 407 E Park Ave, Waterloo IA 50703 INSPECTfQNDETAIJ„S Inspection Date /'Inspection Type 06/17/2025 ( Annual Inspection (1Yr) Other Inspectors N/A Vg' 425 E.3rd Street Inspection Number 14015 Shift Station Unit NIA N/A N/A SUMMARY OF INSPECTION 0 55 0 10 ® 11 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Brad Baldwin brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES Brad Baldwin - 06/18/2025 @ 12:23 $100 annual inspection fee Baldwin - 06/18 • @ 12:23 -Commercial Fire Inspector £€" brad.baldwin@waterloo-ia.org a€" Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 07/1412025 Brad Baldwin - 06/18/2025 @ 12:23 If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday a€" Friday, 9:00 a.m. a€" 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. Brad Baldwin - 06/23/2025 @ 07:42 Corrected during inspection: (A) Park Ave lounge bar area, removed multi -plug cord. (B) Brass lounge, removed multi -plug cord. (C) Stag Bar, removed multi -plug cord from TV. (D) Removed multi -plug cord from organ Brad Baldwin - 06123/2025 @ 07:42 Kitchen hood suppression system due for inspection 8/27/25. SIGNATURES Contact signature Inspector signature Sherri Simon CHECKLISTS No signature Report completed post inspection Date: Brad Baldwin 06/23/2025 GENERATED ON 6/23/25, 7:48 AM 1 OF 6 Emergency Equipment Status Code Fail 1203.2.6 Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. General Housekeeping Statue Code Fail 304.3.1 Materials susceptible to spontaneous ignition, such as oily rags, shall be stored in a listed disposal container. Contents of such containers shall be removed and disposed of daily. Fire Service Features States Code Fail EXD 509.2 Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. 509.2 Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Description Location: Kitchen Up Comments: Repair or replace exit sign that failed to illuminate during testing Description Location: Kitchen Up Comments: Provide listed container for oily rag disposal Description Location: Garage pull station Comments: Remove obstructions to clear path to fire alarm pull station. Location: Down kitchen Comments: Remove obstructions in front of hood suppression pull station, maintain clear path. GENERATED ON 6/23/25, 7:48 AM 2 OF 6 Additional Codes Status Gode Fail O Fail 0 5303.5.3 Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellersa€ "" warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 907.8.4 The building owner shall be responsible to maintain the fire and life safety systems in an operable condition at all times. Service personnel shall meet the qualification requirements of NFPA 72 for inspection, testing and maintenance of such systems. Records of inspection, testing and maintenance shall be maintained. De ptlo Location: Liquor storage room Comments: Secure compressed gas cylinders with chain to avoid tip over. Location: Red stag brass lounge storage closet Comments: Repair or replace smoke detector "S-27" hanging by wires, loose to box. GENERATED ON 6/23/25, 7:48 AM 3 OF 6 Electrical Safety -` umu*s Code Fail Fail 603.2 Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.5 Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and retocatable taps shall be in accordance with NFPA 70 and this code. Description Location: Walk-in freezer near garage Comments: Repair or replace damaged protective wiring jacket to freezer door. Location: Park Ave lounge bar area Comments: Remove multi -plug adapter from beverage fridge. Fridge shall be directly plugged in to wall outlet. GENERATED ON 6/23/25, 7:48 AM 4 OF 6 Portable Fire Extingusihers Status Code Fail C Fail 906.2 Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. 906.7 Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturerd€TM's installation instructions. Description Location: All fire extinguishers Comments: Provide annual service to extinguishers, due by end of June 2025. Location: Kitchen Up Comments: Provide and install "K Guard" fire extinguisher on wall bracket. Extinguisher shall be no less than 4" from the floor, no more than 5' in height from the floor. GENERATED ON 6/23/25, 7:48 AM 5 OF 6 Statement of Fees FEE invoice Date Inspection Fee Date Paid Amount Paid N/A $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 6/23/25, 7:48 AM 6 OF 6