Loading...
HomeMy WebLinkAbout1501 E SAN MARNAN DR0 Customer #: 4661 TARGET STORE T1792 PO BOX 111 MINNEAPOLIS, MN 55440 INVOICE DATE ' DUE DATE INVOICE # TOTAL DUE 07/09/2025 08/12/2025 2026-00000024 $610.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1501 E SAN MARNAN DR - 6-17-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 100,000 OCCUPANCY FEE Total Price $600.00 $10.00 CUSTOMER #' 4661 BILLING DATE 07/09/2025 DUE DATE 08/12/2025 INVOICE # 2026-00000024 CHARGES $610.00 Less Prepayment Total Due —> City of Waterloo $0.00 S610.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue -Inspect • Report Target Super Store 1501 E San Marnan DR, BLDG 1501 E San Marnan Dr, Waterloo IA 50702 INSPECTION - r LS inspection Date 06/17/2025 Brad Baldwin Other Inspectors NIA Inspection Type 425 E. 3rd Street Inspection Number 14075 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 0 56 Passed codes NEXT STEPS 0 11 Failed codes 9 N/A codes Please direct questions about your Inspection to: Brad Baldwin brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES Brad Baldwin - 06118/2025 @ 07:47 (,,,....___ $610 annual inspection fee Brad Baldwin - 06/18/2025 @ 07:48 -Commercial Fire Inspector a€" brad.baldwin@waterloo-ia.org a€" Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 07/09/2025 Brad Baldwin - 06/1812025 @ 07:48 If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday a€" Friday, 9:00 a.m. a€" 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Kyle (2025) floor manager CHECKLISTS EJ3 Date: Brad Baldwin 06/18/2025 GENERATED ON 6/18/25, 9:05 AM 1 OF 5 Means of Egress Status Code Fail 1010.1.3 The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Emergency Equipment Status Code Fail Fail 1203.4.3 Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. 1203.4.3 Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. Description Location: Near aisle B Comments: Repair or replace exit door that failed to open without special force or knowledge. (West door) Description Location: Emergency lighting & exit lights Comments: Provide current annual emergency exit and egress light testing with all discrepancies corrected. Include signature and date. Location: Emergency power generator Comments: Service/load bank testing of generator 382 days past due as of 6/18/25. Provide service to generator, report of service and load bank test shall be uploaded to Compliance Engine. GENERATED ON 6/18/25, 9:05 AM 2 OF 5 Fire Sprinkler System Status Code Fail Fail 5.2.1 Sprinklers shall be inspected at least annually by licensed contractor 903.3.3 Automatic sprinklers shall be installed with regard to obstructions that will delay activation or obstruct the water distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used. Automatic sprinklers shall be installed in or under covered kiosks, displays, booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width. Not less than a 3-foot (914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire -extinguishing system in accordance with Section 904. Additional Codes Status Code Fail Fail 603.9.2 Portable, electric space heaters shall be plugged directly into an approved receptacle. 606.3.1 The ventilation system in connection with hoods shall be operated at the required rate of air movement, and grease filters listed and labeled in accordance with UL 1046 shall be in place where equipment under a kitchen grease hood is used. Commercial Cooking Hood Suppression System Status Code Fail Fail a 606.3.3 Hoods, grease -removal devices, fans, ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. 606.3.3.3 Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Description Location: Sprinkler system Comments: Provide correction to deficiency noted in report uploaded in Compliance Engine. Report of correction must be uploaded by contractor once completed. Location: 2nd floor Onan generator room Comments: Remove dust and all obstructions to sprinkler heads Description Location: Ray Echols office Comments: Remove space heater from power strip. Location: Deli kitchen Comments: Repair or replace damaged kitchen exhaust hood filter Description Location: Kitchen exhaust cleaning Comments: Cleaning 309 days past due as of 6/18/25. Provide cleaning of exhaust system, report of cleaning shall be uploaded to Compliance Engine. Location: Kitchen hood fire suppression inspection Comments: Provide kitchen hood exhaust system fire suppression inspection report with all discrepancies corrected. Currently 140 days past due as of 6/18/25. Contractor must upload online to the Compliance Engine. GENERATED ON 6/18/25, 9:05 AM 3 OF 5 Fire Resistant Construction Maintenance Status Code Fail 704.1 Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall, 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Portable Fire Extingusihers Status Code Fail 906.2 Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Electrical equipment room near check lane storage Comments: Replace missing ceiling tiles. Descript Location: All fire extinguishers Comments: Provide annual service to fire extinguishers, due by end of June 2025. GENERATED ON 6/18/25, 9:05 AM 4 OF 5 Statement of Fees FEE Invoice Date Inspection Fee N/A $610.00 Invoice Number NIA Date Paid Amount Paid Check Number N/A Transaction Number N/A GENERATED ON 6/18/25, 9:05 AM 5 OF 5