Loading...
HomeMy WebLinkAbout2206 KIMBALL AVECustomer #: 3423 FAMILY DOLLAR STORE 500 VOLVO PARKWAY CHESAPEAKE, VA 23320 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/09/2025 08/12/2025 2026-00000007 $200.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2206 KIMBALL AVE - 6-26-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 3 $200.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 3423 07/09/2025 08/12/2025 2026-00000007 $200.00 Less Prepayment Total Due -* City of Waterloo $0.00 $200.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Won Repor-AN\ Family Dollar - 2206 Kimball AVE, I DG 2206 Kimball Ave, Waterloo IA 50701 INSPECTIO ILS Insppcttoa Date ( 06/26/2025 ad Inspect Bra aldwin Inspection Type Annual Inspection (1Yr REINSPECTION Other Inspectors N/A Shift 425 E. 3rd Street Inspection Number 10713-R6 Station Unit N/A N/A SUMMARY OF INSPECTION O 0 Passed codes NEXT STEPS 0 9 Failed codes Please direct questions about your Inspection to: Brad Baldwin brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES JEFF SIEBEL - 10/14/2024 @ 08:31 annual inspection $80 JEFF SIEBEL - 10/14/2024 @ 08:31 No storage allowed in aisles for stock. One aisle has boxes of merchandise along one side. JEFF SIEBEL - 1011412024 @ 08:31 correct all violations to avoid progressive re -inspection fees beginning at $100. JEFF SIEBEL - 10/14/2024 @ 08:31 re -inspection fee $100. provide all corrections to avoid $150 re -inspection fee at next visit. JEFF SIEBEL - 10/14/2024 @ 08:31 re -inspection fee $150 JEFF SIEBEL - 10/1412024 @ 08:31 /nsPectionfezz Brad Baldwin - 0612712025 @ 08:48 $200 re -inspection fee for failure to correct deficiencies on 6/26/25 S I G /'F H{iF.S. Contact signature Inspector signature JoAnne Mitchell No signature Report completed post inspection Reinspection Date 07/1812025 Date: Brad Baldwin 06/2712025 GENERATED ON 6/27/25, 8:52 AM 1 OF 6 CHECKLISTS Reinspection staws Fail Fail Cede 1203.2.15 Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Description Location: outside of building above back (west) exit door Comments: repair outside egress light. Additional comments: 6/26/25- Deficiency still remains Location: Back wall of store above paper goods Comments: repair exit light. Additional comments: 6126/25- Deficiency still remains GENERATED ON 6/27/25, 8:52 AM 2 OF 6 Additional Codes Slakes Code Fail Fail Fail Fail x 1203.4.3 Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. 509.2 Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. 603.2 Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2 Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Description Location: South wall emergency lighting above coolers Comments: Provide report, signed and dated of testing of emergency lighting. Emailed report to inspector will be approved. Location: Back storage room/basement Comments: Remove obstructions to clear path to basement door containing sprinkler riser room in basement for firefighters access. Location: Back storage room near water heater Comments: Microwave and 2 fridge appliances shall be plugged directly to wall outlet. Remove appliances from power strip. Location: Red Bull fridge near check out area Comments: Remove fridge from power strip, appliance shall be plugged directly to wall outlet. GENERATED ON 6/27/25, 8:52 AM 3 OF 6 Fail 603.2.2 Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Basement near ejector pit Comments: Repair or replace outlet and cover loose to box. GENERATED ON 6/27/25, 8:52 AM 4 OF 6 Fail Fail 603.4 A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not Tess than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). 906.2 Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Back storage room Comments: Maintain clear 36" space in front of electrical panels. Location: Basement Comments: Provide annual service to extinguisher, last serviced March 2024. GENERATED ON 6/27/25, 8:52 AM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee N!A $200.00 Date Paid Amount Paid Invoice Number N/A Check Number NIA Transaction Number NIA GENERATED ON 6/27/25, 8:52 AM 6 OF 6