Loading...
HomeMy WebLinkAbout324 FLETCHER AVECustomer #: 3360 KWIK STAR #732 1626 OAK ST LA CROSSE, WI 54602 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/09/2025 08/12/2025 2026-00000015 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 324 FLETCHER AVE - 6-16-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 3360 07/09/2025 08/12/2025 2026-00000015 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection --Report Kwik'PR&#�W 324 Fletcheh AVE, BLDG 324 Fletcher Ave, Waterloo IA 50701 INSPECTIO _ nspectian Date 06116/2025 cad Inspec .r Brad Baldwin Inspection Type Annual Inspection (1Yr) Other Inspectors N/A 425 E. 3rd Street Inspection Number 14146 Shift Station Unit N/A NIA NIA SUMMARY OF INSPECTION 052 d 9 ®17 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Brad Baldwin brad.baldwin@waterloo-ia.org, 3192914319 GENERAL OTES Brad Baldwin - 06/1712025 @ 08: 80.00 annual inspection fe 4 Brad Baldwin - 06/17/2025 @ 08:15 -Commercial Fire Inspector a€" brad.baldwin@waterloo-ia.org a€" Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 07/15/2025 Brad Baldwin - 06/17/2025 @ 08:15 If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday a€" Friday, 9:00 a.m. a€" 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. Brad Baldwin - 06118/2025 @ 07:45 Violations corrected during inspections: (A)Extension cord from behind coffee machines ran through kitchen doorway to fan removed. Brad Baldwin - 06123/2025 @ 14:41 Use of disposable kitchen rags shall be routinely discarded out of the building to avoid from potential spontaneous ignition in the building. Brad Baldwin - 06/23/2025 @ 14:42 Kitchen exhaust hood cleaning due 9/6/25. Hood suppression system due 915125 SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Alicia (2025) District Manager Date: Brad Baldwin 06/2312025 GENERATED ON 6/23/25, 2:50 PM 1 OF 7 CHECKLISTS Additional Codes Status Code Fail 102.4 The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Emergency Equipment Status Code Fail 1203.2.6 Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Description Location: Back storage room Comments: Obtain proper permits and inspection of installed water heater. Description Location: Back storage exit door Comments: Repair or replace exit sign and emergency lighting that failed to stay lit during testing. GENERATED ON 6/23/25, 2:50 PM 2 OF 7 Electrical Safety Status, Curie Fail 0 Fail 0 Fail 603.2.2 Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Description Location: Outlet behind ATM at front of building Comments: Provide proper outlet cover missing. Location: Back storage area near water heater Comments: Provide proper plug for opening in top of outlet box. Location: South exterior of carwash building Comments: Provide proper cover to outlet GENERATED ON 6/23/25, 2:50 PM 3 OF 7 Fail Fail 0 603.4 A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). 603.4 A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Back storage area Comments: Remove obstructions within 36" in front of electrical panels. Location: Office near checkout area Comments: Remove obstructions in front of electrical panel within 36" GENERATED ON 6/23/25, 2:50 PM 4 OF 7 Fail 603.4 A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Electrical Panel "F" Comments: Remove bun rack and maintain 36" clearance in front of panel GENERATED ON 6/23/25, 2:50 PM 5 OF 7 Portable Fire Extingusihers Status Code Fail 906.2 Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Near diesel & natural gas pumps Comments: Provide documentation of service to fire extinguishers. GENERATED ON 6/23/25, 2:50 PM 6 OF 7 Statement of Fees FEE Invoice Dale Inspection Fee N/A $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 6/23/25, 2:50 PM 7 OF 7