Loading...
HomeMy WebLinkAbout2600 E SHAULIS RDIIJII U9110H1 y — i INVOICE DATE DUE DATE INVOICE # TOTAL DUE 05/20/2025 06/25/2025 2025-00000348 $610.00 Customer #: 24708 LOST ISLAND THEME PARK 2600 E SHAULIS RD WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN:: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2600 E SHAULIS RD - 4-29-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 100,000 OCCUPANCY FEE $600.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24708 05/20/2025 06/25/2025 2025-00000348 $610.00 Less Prepayment Total Due --> City of Waterloo $0.00 $610.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Main Administration Office - 2600 E Shaulis Rd, BLDG Main Administration Office, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 04129/2025 Lead Inspector JEREMIAH VANDYKE Inspection Type Annual Inspection (1Yr) U3h() ©S G 425 E. 3rd Street CIA Other lnspectors JEFF SIEBEL, BROCK WELIVER Shift NIA Station NIA Inspection Number 14070 Unit N/A SUMMARY OF INSPECTION 0 57 Passed codes NEXT STEPS 0 7 Failed codes 9 N/A codes Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org FEE Invoice Date Date Paid Amount Paid N/A :voice Number N/A GENERAL NOTES JEREMIAH VANDYKE - 04130/2025 @ 20:45 Fire Extinguisher serviced by Proshield April 2025. NIA Reinspection Date 05/3112025 Transaction Number NIA JEREMIAH VANDYKE - 04/30/2025 @ 21:29 All buildings inspected are on this report except Whale Bone, Maintenance shop, Volkanu , Thirsty Voyager, and Totara market which have individual reports due to the fire safety systems installed in them. JEREMIAH VANDYKE - 04/30/2025 @ 21:31 Egress/Exit lighting report needed for all buildings on Property that have Egress and Exit lighting. JEREMIAH VANDYKE - 05/01/2025 @ 14:27 Report needed for last Clothes Dryer vents located in Maintenance building. JEREMIAH VANDYKE - 05/01/2025 @ 14:42 Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org A€" Work: 319-291-4460 - Cell: 319-883-1615 JEREMIAH VANDYKE - 05101/2025 @ 14:42 Inspection Fee for entire property = $610.00 (To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature GENERATED ON 5/1/25, 9:49 AM 1 OF 4 No signature NA Eric Bertch Date: CHECKLISTS Emergency Equipment Status Fail Fail Fail Code 1203.2.15 Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. 1203.4.3 Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. General Housekeeping Status Fail F Code 315.3.2 Combustible materials shall not be stored in exits or enclosures for stairways and ramps. Combustible materials in the means of egress during construction, demolition, remodeling or alterations shall comply with Section 3312.3. Fire Service Features Status Fail Code 505.1 New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not Tess than 4 inches (102 mm) high with a minimum stroke width of 1/2 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Description Location: ALL buildings on property. Comments: Multiple egress lights through out property were tested and failed. Had issues with same lights. Discussed with Eric starting a Record log of testing and maintaining egresslexit lights. Location: ALL Buildings on property. Comments: Multiple egress lights through out property were tested and failed. Had issues with same lights. Discussed with Eric starting a Record log of testing and maintaining egresslexit lights. Location: ALL buildings on property. Comments: Multiple egress lights through out property were tested and failed. Had issues with same lights. Discussed with Eric starting a Record log of testing and maintaining egresslexit lights. Description Location: Volkanu Comments: Storage in exit hallways X2 during winter, will be moved before opening day. Storage was for rides that need to be set up for summer. Description Location: Address of both Water and Theme park. Comments: Discussed with Eric about having Address numbering for both Parks. GENERATED ON 5/1/25, 9:49 AM 2 OF 4 Fire Resistant Construction Maintenance Status /�Fail lJ Code 704.1 Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floorlceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Portable Fire Extingusihers Status Fail F� Code 906.1 Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10- pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not Tess than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I- 1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally Description Location: Whale Bone ceiling at the Employee serving window. Comments: Ceiling tiles need to be replaced. Description Location: Kotaki & Udaran Comments: Fire extinguishers were in storage and not installed for the summer at the 2 locations above. Workers were currently setting up and cleaning location. Will have them installed when work completed. GENERATED ON 5/1/25, 9:49 AM 3 OF 4 unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. GENERATED ON 5/1125, 9:49 AM 4 OF 4