Loading...
HomeMy WebLinkAbout421 OAK AVEINVOICE DATE , DUE DATE INVOICE # TOTAL DUE 05/20/2025 06/25/2025 2025-00000340 $80.00 Customer #: 23235 THE ROSE OF WATERLOO ATTN: DIANE MURPHY - OPEN ARMS 421 OAK AVE WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 421 OAK AVE - 5-8-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23235 05/20/2025 06/25/2025 2025-00000340 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report The Rose - 421 Oak AVE, BLDG 421 Oak Ave, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 05/08/2025 Lead Inspector Inspection Type Residential Common Areas Inspection 425 E. 3rd Street Inspection Number 13206 Shift Station Unit JEREMIAH VANDYKE N/A N/A N/A Otherinspectors Brad Baldwin SUMMARY OF INSPECTION 026 02 Q3 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $80.00 Reinspection Date 06107/2025 Invoice Number Check Number Transaction Number N/A N/A N/A GENERAL NOTES JEREMIAH VANDYKE - 05/08/2025 @ 20:39 Fire extinguishers serviced by Continental Fire Jan 2025. JEREMIAH VANDYKE - 05/08/2025 @ 20:41 Generator serviced by Hawkeye Electrical contractors of Cedar Rapids. 3/3/2025. JEREMIAH VANDYKE - 05/08/2025 @ 20:42 Dryers cleaned by AKA 9/4/2024. Invoice #11982 JEREMIAH VANDYKE - 05/08/2025 @ 20:42 /10/2025 S - 5 Year Sprinkler CONTINENTAL FIRE SPRINKLER CO. Reviewed Compliant JEREMIAH VANDYKE - 05/08/2025 @ 20:42 4/10/2025 S - (Semi -Annual) Fire Sprinkler CONTINENTAL FIRE SPRINKLER CO. Reviewed Compliant JEREMIAH VANDYKE - 05/08/2025 @ 20:43 1/7/2025 S - Kitchen Hood Suppression CONTINENTAL FIRE SPRINKLER CO. Reviewed Compliant JEREMIAH VANDYKE - 05/08/2025 @ 20:43 117/2025 S - (Annual) Fire Alarm CONTINENTAL FIRE SPRINKLER CO. Reviewed Compliant JEREMIAH VANDYKE - 05/08/2025 @ 20:43 1/7/2025 S - (Annual) Kitchen Exhaust CONTINENTAL FIRE SPRINKLER CO. Reviewed Compliant GENERATED ON 5/8/25, 3:47 PM 1 OF 2 JEREMIAH VANDYKE - 05/08/2025 @ 20:43 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday &C" Friday, 8:00 a.m. a€" 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. "****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 05/08/2025 @ 20:43 Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org &€" Work: 319-291-4460 - CeII: 319-883-1615 JEREMIAH VANDYKE - 05/08/2025 @ 20:45 Inspection Fee = $80.00 (To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature No signature NA Gladys Rainey CHECKLISTS Date: JEREMIAH VANDYKE Residential Common Areas Inspection Status Fail O Fail Code 1104.5 Where means of egress illumination is provided, the power supply for means of egress illumination shall normally be provided by the premises&€T" electrical supply. In the event of power supply failure, illumination shall be automatically provided from an emergency system for the following occupancies where such occupancies require two or more means of egress: 1.Group A having 50 or more occupants. Exception: Assembly occupancies used exclusively as a place of worship and having an occupant Toad of less than 300. 2.Group B buildings three or more stories in height, buildings with 100 or more occupants above or below a level of exit discharge serving the occupants or buildings with 1,000 or more total occupants. 3.Group E in interior exit access and exit stairways and ramps, corridors, windowless areas with student occupancy, shops and laboratories. 4.Group F having more than 100 occupants. Exception: Buildings used only during daylight hours and that are provided with windows for natural light in accordance with the International Building Code . 5.Group I. 6.Group M. Exception: Buildings less than 3,000 square feet (279 m2) in gross sales area on one story only, excluding mezzanines. 7.Group R-1. Exception: Where each sleeping unit has direct access to the outside of the building at grade. 8.Group R-2. Exception: Where each dwelling unit or sleeping unit has direct access to the outside of the building at grade. 705.2.4 Swinging fire doors shall close from the full -open position and latch automatically. Description Location: Near room 205 05/08/2025 Comments: Egress light tested and failed. Send picture after repair 319-883-1615. Location: Near room 316 hallway double doors. Comments: Send video after repairing/adjustment. 319-883-1615 GENERATED ON 5/8/25, 3:47 PM 2 OF 2