Loading...
HomeMy WebLinkAbout610 E 4TH STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 05/20/2025 06/25/2025 2025-00000351 $100.00 Customer #: 11098 RENAISSANCE PARK APT 610E4TH ST WATAERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 610 E 4TH ST - 5-9-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 HH OCCUPANCY FEE $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 11098 05/20/2025 06/25/2025 2025-00000351 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Renaissance Park Apartments - 610 E 4th ST, BLDG 610 E 4th St, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 05/09/2025 Lead Inspector JEREMIAH VANDYKE Inspection Type Residential Common Areas Inspection OrherInspectors NIA 425 E. 3rd Street Inspection Number 14043 Shift Station Unit N/A N/A NIA SUMMARY OF INSPECTION 0 25 Passed codes NEXT STEPS 0 5 0 3 Failed codes N/A codes Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org FEE Invoice Date Inspection Fee NIA $100.00 Date Paid Amount Paid Invoice Number NIA GENERAL NOTES JEREMIAH VANDYKE - 05/09/2025 @ 19:52 Fire extinguishers serviced by Proshield Nov. 2024. Check Number NIA JEREMIAH VANDYKE - 05/09/2025 @ 19:53 Last dryer cleaning logged and recorded 1/5/2025. Need to maintain dryer cleaning log. JEREMIAH VANDYKE - 05/09/2025 @ 19:53 9/4/2024 S - (Annual) Fire Alarm COMMUNITY ELECTRIC/PRIMARY SYSTEMS Reviewed Compliant JEREMIAH VANDYKE - 05/09/2025 @ 19:58 Reinspection Date 06108/2025 Transaction Number NIA Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday a€" Friday, 8:00 a.m. A€" 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 05/09/2025 @ 19:58 Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org A€" Work: 319-291-4460 - Cell: 319-883-1615 JEREMIAH VANDYKE - 05/09/2025 @ 19:58 Inspection Fee = $100.00 (To be mailed out by City via snail mail.) SIGNATURES Contact signature GENERATED ON 5/9/25, 2:59 PM Inspector signature 1 OF 3 No signature NA vp Vicki Seichter Date: JEREMIAH VANDYKE 05109/2025 CHECKLISTS Residential Common Areas Inspection Status Fail 0 Fail Fail Fail Code Description 1104.5 Where means of egress illumination is provided, the power supply for means of egress illumination shall normally be provided by the premisesaCr" electrical supply. In the event of power supply failure, illumination shall be automatically provided from an emergency system for the following occupancies where such occupancies require two or more means of egress: 1.Group A having 50 or more occupants. Exception: Assembly occupancies used exclusively as a place of worship and having an occupant load of Tess than 300. 2.Group B buildings three or more stories in height, buildings with 100 or more occupants above or below a level of exit discharge serving the occupants or buildings with 1,000 or more total occupants. 3.Group E in interior exit access and exit stairways and ramps, corridors, windowless areas with student occupancy, shops and laboratories. 4.Group F having more than 100 occupants. Exception: Buildings used only during daylight hours and that are provided with windows for natural Tight in accordance with the International Building Code . 5.Group 1. 6.Group M. Exception: Buildings less than 3,000 square feet (279 m2) in gross sales area on one story only, excluding mezzanines. 7.Group R-1. Exception: Where each sleeping unit has direct access to the outside of the building at grade. 8.Group R-2. Exception: Where each dwelling unit or sleeping unit has direct access to the outside of the building at grade. 901.6 Fire detection and alarm systems, emergency alarm systems, gas detection systems, fire -extinguishing systems, mechanical smoke exhaust systems and smoke and heat vents protection and life safety systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected, tested and maintained or removed in accordance with Section 901.8 . 901.6 Fire detection and alarm systems, emergency alarm systems, gas detection systems, fire -extinguishing systems, mechanical smoke exhaust systems and smoke and heat vents protection and life safety systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected, tested and maintained or removed in accordance with Section 901.8 . 901.6 Fire detection and alarm systems, emergency alarm systems, gas detection systems, fire -extinguishing systems, mechanical smoke exhaust systems and smoke and heat Location: South Stairwell between floors 3 & 4 and 4 & 5 egress lights. Comments: Tested egress lights and failed. Send picture of working egress light to 319-883-1615. Location: Sprinkler and Standpipe inspection past due. Comments: Contact sprinkler contractor for inspection as soon as possible. Location: Boiler inspection report. Comments: Need copy of last boiler inspection report. Discussed with Mario on what he needs to maintain on site for boilers, I advised him to discuss with boiler contractor on what needs to be recorded and logged. Location: Rated fire doors in stairways and apartments. GENERATED ON 5/9/25, 2:59 PM 2 OF 3 Fail vents protection and life safety systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected, tested and maintained or removed in accordance with Section 901.8 . 906.1 Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10- pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I- 1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Comments: Need to remove the paint from Fire rated tags on door and frames. Location: Rooftop penthouse. Comments: Fire extinguisher is past due in penthouse. Need to have serviced and re tagged. GENERATED ON 5/9/25, 2:59 PM 3 OF 3