Loading...
HomeMy WebLinkAbout2225 E SHAULIS RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 05/20/2025 06/25/2025 2025-00000343 $100.00 Customer #: 10030 LOST ISLAND WATER PARK 2225 E SHAULIS RD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2225 E SHAULIS RD - 4-16-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 20,000 OCCUPANCY FEE Total Price $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 10030 05/20/2025 06/25/2025 2025-00000343 $100.00 Less Prepayment Total Due — > City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE 10° INSPECTION REPORT LOST ISLAND WATERPARIC 2225 E SHAULIS RD, BLDG 222S E SHAULIS RD, WATERLOO 0 50702 )U DETAILS Inspection Date: 04/16/2025 I Inspection Type: Annual Inspection (1Yr) Inspection Number: 13809 Shift: N/A I Station: N/A I Unit: N/A I Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 37 I Violations: 8 I N/A Codes: 31 STATUS CODE DESCRIPTION FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Maintenance Building Original Comment: repair exit/egress light above exterior door. FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Sales East - South Door Original Comment: repair exit/egress light FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Office East Door Original Comment: Repair exit/egress light Printed on 04/17/2025 @ 09:39 Page 1 of 4 STATUS CODE DESCRIPTION /AIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. FAI L 603.2.2 - Unapproved conditionsOpen electrical terminations. Location: Merchandise room Original Comment: Repair exit light Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Coaster QUE Original Comment: Replace missing waterproof outlet cover FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not Tess than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Castaway Bathroom Electrical Room Original Comment: Maintain minimum 36" clearance to all trasformer and all electrical equipment. Printed on 04/17/2025 @ 0939 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 904.13.5.2 - Extinguishing Automatic fire -extinguishing systems shall be serviced not less frequently than system service. every six months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. FAI L Location: All buildings hood fire suppression systems Original Comment: Provide current semi-annual kitchen hood fire suppression inspection reports with all discrepancies corrected. Currently 14 days past due. Contractor must upload online to the compliance engine. Chapter 14 - Inspection, Fire alarm system tested at least annually by licensed contractor testing, and maintenance GENERAL NOTES JEFF SIEBEL - 04/17/2025 @ 08:55 JEFF SIEBEL - 04/17/2025 @ 09:05 REINSPECTION DATE 05/06/2025 CONTACT SIGNATURE Jesse Henry Signed on: 04/17/2025 @ 09:38 Location: Maintenance Builidng Original Comment: Installing contractor must obtain a permit for new panel and must call for final inspection and acceptance testing. Annual Inspection $100 Private fire hydrant inspection due 5/9/25 Printed on 04/17/2025 @ 09:39 Page 3 of 4 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 04/17/2025 @ 09:38 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 04/17/2025 @ 09:39 Page 4 of 4