Loading...
HomeMy WebLinkAbout1815 LA PORTE RDCustomer #: 6647 WENDY'S 1815 LA PORTE RD WATERLOO, IA 50702 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 05/20/2025 06/25/2025 2025-00000342 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1815 LA PORTE RD - 5-6-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 6647 05/20/2025 06/25/2025 2025-00000342 $80.00 Less Prepayment Total Due --> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Wendy's - 1815 La Porte RD, BLDG 1815 La Porte Rd, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 05/06/2025 Lead Inspector JEREMIAH VANDYKE inspection Type Annual Inspection (1Yr) vo'n Other Inspectors NIA 425 E. 3rd Street Inspection Number 1120 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 042 Passed codes NEXT STEPS 0 4 Failed codes 27 NIA codes Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org FEE Invoice Date Inspection Fee NIA $80.00 Date Paid Amount Paid Reinspection Date 06105/2025 Invoice Number Check Number Transaction Number NIA NIA NIA GENERAL NOTES JEREMIAH VANDYKE - 05/06/2025 @ 20:36 4/1/2025 S - (Semi -Annual) Kitchen Exhaust GETZ FIRE EQUIPMENT CO. Reviewed Compliant JEREMIAH VANDYKE - 05/06/2025 @ 20:37 2/20/2025 S - Kitchen Hood Suppression HAWKEYE FIRE & SAFETY CO. Reviewed Compliant JEREMIAH VANDYKE - 05/06/2025 @ 20:37 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday a€" Friday, 8:00 a.m. A€" 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. "****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 05/06/2025 @ 20:37 Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org A€" Work: 319-291-4460 - Cell: 319-883-1615 JEREMIAH VANDYKE - 05/06/2025 @ 20:43 Inspection Fee = $80.00 (To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature GENERATED ON 5/6/25, 3:44 PM 1 OF 3 No signature Person not available for signature Jacque Behrens - District manager Date: CHECKLISTS Emergency Equipment Status Code Fail Documentation Status Fail JEKEMIAH VANUYKE U5/Uti/'LU2b 1203.2.6 Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required Toad for a duration of not less than 90 minutes. Code 406.3 Employees shall be trained in fire prevention, evacuation and fire safety in accordance with Sections 406.3.1 through 406.3.4. Commercial Cooking Hood Suppression System Status Fail 0 Code 906.4.2 Where hazard areas include deep fat fryers, listed Class K portable fire extinguishers shall be provided as follows: 1.For up to four fryers having a maximum cooking medium capacity of 80 pounds (36.3 kg) each: one Class K portable fire extinguisher of a minimum 1.5-gallon (6 L) capacity. 2.For every additional group of four fryers having a maximum cooking medium capacity of 80 pounds (36.3 kg) each: one additional Class K portable fire extinguisher of a minimum 1.5-gallon (6 L) capacity shall be provided. 3.For individual fryers exceeding 6 square feet (0.55 m2) in surface area: Class K portable fire extinguishers shall be installed in accordance with the extinguisher manufacturers€'"s recommendations. Portable Fire Extingusihers Status Fail 0 Code 906.2 Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit Description Location: Exit/Egress light near fryers and ice machine. Comments: Tested exit/egress light that failed. Will need to be repaired or replaced. Description Location: Records of training for grease fire and use of hood fire suppresion and Class K extinguisher. Comments: Records of training for grease fire and use of hood fire suppresion and Class K extinguisher. Description Location: Silver Class K fire extinguisher sign. Comments: Silver class K fire extinguisher needs new sign above it and PLACED HIGHER UP. Had a hard time locating during the inspection. Description Location: Red fire extinguisher failed. It was tagged Feb. 2025 by Hawkeye fire and safety. Comments: Will need to replace out of service fire extinguisher. GENERATED ON 5/6/25, 3:44 PM 2 OF 3 continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 5/6/25, 3:44 PM 3 OF 3