Loading...
HomeMy WebLinkAbout926 LA PORTE RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 11/19/2024 12/22/2024 2025-00000207 $80.00 Customer #: 24594 M&J CARIBBEAN BAR RESTAURANT 926 LA PORTE RD WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 926 LA PORTE RD - 11-13-24 FOR BILLING INQUIRY: (319)291-4323 [ Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24594 11/19/2024 12/22/2024 2025-00000207 $80.00 Less Prepayment Total Due -* City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOQ FIRE RESCUE INSPECTION REPORT `'--- STEeL371S/1 yI >PmZA l Ma/ CARIBBEAN BAR RESTAURANT,26 LA PORTE RD, BLDG 924 LA DETAILS Inspection Date: 11/13/2024 ; Inspection Type: Annual Inspection (1Yr) Inspection Number: 11403 I Shift: N/A I Station: N/A Unit: N/A Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A j Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 ; Passed Codes: 44 ; Violations: 11 ( N/A Codes: 25 STATUS CODE DESCRIPTION FAIL 1010.1 -Doors. Means Doors in the means of egress shall comply with the requirements of Sections 1010.1.1 through 1010.3.4. Exterior exit doors shall meet also comply with the requirements of this section. Doors serving a Section 1022.2. Gates in the means of egress shall comply with the requirements of Sections 1010.4 and 1010.4.1. Turnstiles in the means of egress system shall meet comply with the requirements of this section and Section 1022.2. Doors Sections 1010.5 through 1010.5.4. Doors, gates and turnstiles provided for egress purposes in numbers greater than required by this code shall meet comply with the requirements of this section. Doors in the Means means of egress doors shall be readily distinguishable from the adjacent construction and finishes such that the doors are easily recognizable as doors. Mirrors or similar reflecting materials shall not be used on means of egress doors. Means of egress doors shall not be concealed by curtains, drapes, decorations or similar materials. Location: Front door in hooka bar Original Comment: Remove curtain from exit door. "Door must not be disguised and must be readily distinguishable from adjacent construction and finishes such that the doors are easely recognizable as doors" Printed on 11 /15/2024 @ 11:56 Page 1 of 7 STATUS CODE DESCRIPTION FAIL 102.4 - Application of building The design and construction of new structures shall comply with the code. International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. FAIL 102.4 - Application of building code. Location: Front Area Original Comment: Hooka Lounge requires specific air exchange rates. Contact building department and Mechanical Inspector for requirements or hire contractor for installation of equipment with permits and inspections. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Location: Stage Original Comment: Obtain building permit and inspections for stage or remove from premises. Printed on 11/15/2024 @ 11:56 Page 2of7 STATUS CODE DESCRIPTION FAIL 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. FAIL FAIL 3505.2 - Cylinder and container storage, handling and use. Location: hooka area, back exit hall by restrooms, common hall exit path in back Original Comment: REmove curtains, tables, saws, ladders and all obstructions to rear exit. Maintain clear un-obstructed path at all times. Storage, handling and use of compressed gas cylinders, containers and tanks shall be in accordance with this section and Chapter 53. Location: In hall by pipe rack Original Comment: CHAIN compressed gas cylinders to wall or pop rack to prevent tip over 4.9 - Support of nonsprinkler Sprinkler system components shall not be used to support non -sprinkler system system components components unless expressly permitted by NFPA 13. Location: dance area Original Comment: remove tape and debris from fire sprinler pipe and hangers. Printed on 11/15/2024 @ 11:56 Page 3 of 7 STATUS FAIL CODE 603.4 - Working space and clearancesclearance. DESCRIPTION A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: back hall Original Comment: remove obstructions to electrical panels. Maintain a minimum of 36" clearance at all times. FAIL 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: ceiling above hooka room Original Comment: remove extension cord to light. extension cords prohibited and not a substitute for permanent power. Printed on 11 /15/2024 @ 11:56 Page 4 of 7 STATUS FAIL CODE DESCRIPTION 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: back room above cooler/freezer Original Comment: replace missing ceiling tile. Fire Sprinkler will not function correctly without tile. Printed on 11/15/2024 @ 11:56 Page 5 of 7 STATUS CODE DESCRIPTION FAIL 807.1 - General. The following requirements shall apply to all occupancies: 1.Furnishings or decorative materials of an explosive or highly flammable character shall not be used. 2.Fire-retardant coatings in existing buildings shall be maintained so as to retain the effectiveness of the treatment under service conditions encountered in actual use. 3.Furnishings or other objects shall not be placed to obstruct exits, access thereto, egress therefrom or visibility thereof. 4.The permissible amount of noncombustible decorative materials shall not be limited. Location: Hooka Area Original Comment: Curtain wall must not obstruct front exit path. The curtains should be listed and labeled to meet NFPA 701 or professionally treated to meet the NfpA 701 standard or may just be removed. FAIL 906.6 - Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. unobscured. GENERAL NOTES Location: back exit hall Original Comment: remove obstructions to fire extinguishers and maintain a mimimum of 36" at all times. JEFF SIEBEL - 11 /15/2024 @ 11:48 annual inspection $80 Printed on 11/15/2024 @ 11:56 Page 6of7 REINSPECTION DATE 12/05/2024 CONTACT SIGNATURE John Alesse Signed on: 11/15/2024 @ 11:53 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 11/15/2024 @ 11:53 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 11/15/2024 @ 11:56 Page 7 of 7