Loading...
HomeMy WebLinkAbout250 WESTFIELD AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 11/19/2024 12/22/2024 2025-00000205 $610.00 Customer #: 23522 COURTYARD BY MARRIOT 250 WESTFIELD AVE WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 250 WESTFIELD AVE - 11-12-24 [ Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 100,000 OCCUPANCY FEE Total Price J $600.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23522 11/19/2024 12/22/2024 2025-00000205 $610.00 Less Prepayment Total Due —* City of Waterloo $0.00 $610.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT COURTYARD BY MARRIOT, 250 WESTFIELD AVE, BLDG 250 WESTFIELD AVE, WATERLOO IA 50701 DETAILS Inspection Date: 11/12/2024 I Inspection Type: Annual Inspection (1Yr) I Inspection Number: 15431 ( Shift: N/A j Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL ( Other Inspectors: N/A I Fee: $610.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 ( Passed Codes: 48 I Violations: 12 I N/A Codes: 16 STATUS CODE DESCRIPTION FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Light # 11 Original Comment: Repair exit light FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: exit light #614 by room 630 Original Comment: repair exit light Printed on 11/15/2024 @ 15:22 Page 1 of 6 STATUS CODE DESCRIPTION FAI L 1203.4.3 - Records. Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. FAI L FAI L Location: Entire Building Original Comment: Provide documentation that all emergency exit and egress lights have been tested and repaired. Thanks 2015 IFC - Fire alarm testing Is the fire alarm system powered, operational and displaying normal operation and maintenance (no troubles, supervisory, or alarms)? 603.5 - Relocatable power taps and current taps.Multiplug adapters. Location: Room 341 Original Comment: repair smoke detector that is hanging by wires. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: Telecom room by 207 Original Comment: Properly mount power strip to wall . Power strip must not hang by cords. Printed on 11/15/2024 @ 15:22 Page 2of6 STATUS CODE DESCRIPTION FAIL 603.5.2 - Application and Relocatable power taps and current taps shall be directly connected to a usePower supply. permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Location: General Manager Office Original Comment: Refrigerator and Microwave each must plug directly into permanent wall outlet. FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. FAI L Location: Carry over from 2023 annual report. Kitchen hood exhaust system cleaning inspection report Original Comment: Provide corrections for 3 deficiencies on report from AKA dated 7/8/24 . 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Location: Mechanical room by room 601 Original Comment: repair door. Fire door must completely self -close and latch. Printed on 11/15/2024 @ 15:22 Page 3of6 STATUS CODE DESCRIPTION FAIL 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Location: Telecom room 6th floor by pool equipment room Original Comment: Repair door. Fire door must completely self -close and latch. FAI L 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Location: Room 441 Original Comment: repiair door . Fire door must completely self -close and latch. FAIL 903.3.3 - Obstructed Automatic sprinklers shall be installed with regard to obstructions that will delay locations. activation or obstruct the water distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used. Automatic sprinklers shall be installed in or under covered kiosks, displays, booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width. Not less than a 3-foot (914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire -extinguishing system in accordance with Section 904. Location: Laundry Room Original Comment: clear dryer lint and other debris from fire sprinkler heads. Printed on 11/15/2024 @ 15:22 Page 4of6 STATUS CODE DESCRIPTION FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Not Provided Original Comment: Provide annual service for fire extinguishers GENERAL NOTES JEFF SIEBEL -11 /15/2024 @ 15:00 Annual inspection $610 REINSPECTION DATE 12/03/2024 CONTACT SIGNATURE Ben Chase Signed on: 11/15/2024 @ 15:21 n Printed on 11/15/2024 @ 15:22 Page 5 of 6 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 11 /15/2024 @ 15:21 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 11 /152024 @ 15:22 Page 6 of 6