Loading...
HomeMy WebLinkAbout503 SOUTH STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 11/19/2024 12/22/2024 2025-00000203 $100.00 Customer #: 12081 GROUT MUSEUM 503 SOUTH ST WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 503 SOUTH ST - 11-18--24 FOR BILLING INQUIRY: (319)291-4323 [Description INSPECTION 20,000 OCCUPANCY FEE Total Price J $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 12081 11/19/2024 12/22/2024 2025-00000203 $100.00 Less Prepayment Total Due —� City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT GROUT MUSEUM, 503 SOUTH ST, BLDG 503 SOUTH ST, WATERLOO /A 50702 DETAILS Inspection Date: 11/18/2024 j Inspection Type: Annual Inspection (1Yr) ! Inspection Number: 11455 j Shift: N/A I Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL j Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 41 ( Violations: 5 I N/A Codes: 28 STATUS CODE FAI L DESCRIPTION 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in illumination. accordance with Sections 1008.3 and 1104.5.1. Location: classroom #3 Original Comment: repair egress light FAIL 1203.4.3 - Records. Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. Location: Entire building including all Central Battery Systems Original Comment: Provide documentation testing and reair of all emergecy egress and exit lights with all discrepancies corrected with signature and date. Printed on 11 /19/2024 @ 07:31 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Galley in Basement Original Comment: replace 2 missing ceiling tile. FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Library Office Original Comment: replace missing ceiling tile Printed on 11 /192024 @ 07:31 Page 2of3 STATUS CODE DESCRIPTION FAIL 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Location: Hall outside of classroom #2 Original Comment: mount fire extingiusher in an accessible location 42" above floor. GENERAL NOTES JEFF SIEBEL - 11/19/2024 @ 07:30 annual inspection fee $100 REINSPECTION DATE 12/09/2024 CONTACT SIGNATURE Alan Sweeney Signed on: 11/19/2024 @ 07:27 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 11/19/2024 @ 07:28 QUESTIONS AEOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 11 /19/2024 @ 07:31 Page 3 of 3