Loading...
HomeMy WebLinkAbout325 COMMERCIAL STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 12/04/2024 01/08/2025 2025-00000217 $100.00 Customer #: 22975 SINGLE SPEED 325 COMMERCIAL ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 325 COMMERCIAL ST - 11-20-24 [ Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 20,000 OCCUPANCY FEE Total Price ] $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 22975 12/04/2024 01/08/2025 2025-00000217 $100.00 Less Prepayment Total Due --> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT SINGLE SPEED BREWING, 325 COMMERCIAL ST, BLDG 325 COMMERCIAL ST, WATERLOO /A 50702 DETAILS Inspection Date: 11/20/2024 j Inspection Type: Annual Inspection (1Yr) ; Inspection Number: 11617 j Shift: N/A ! Station: N/A j Unit: N/A j Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 41 I Violations: 14 I N/A Codes: 21 STATUS CODE DESCRIPTION FAIL 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in illumination. accordance with Sections 1008.3 and 1104.5.1. Location: By North Door by Dock Original Comment: repair egress light Printed on 11 /212024 @ 09:41 Page 1 of 10 STATUS CODE DESCRIPTION FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. FAIL 1203.2.6 - Exit signs. Location: from by shuffle board to dining area Original Comment: repair exit/egress light. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: South side on outside patio Original Comment: repair exit/egress light Printed on 11 /21 /2024 @ 09:41 Page 2 of 10 STATUS FAIL CODE 1203.2.6 - Exit signs. DESCRIPTION Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: North side outside patio Original Comment: repair exit/egress light Printed on 11/21/2024 @ 09:41 Page 3 of 10 STATUS CODE DESCRIPTION FAIL 1203.4.3 - Records. Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. FAI L Location: Egress light above tanks in brewery Original Comment: provide documentation of testing and repair of egress light . 2015 IFC - Fire alarm testing Is the fire alarm system powered, operational and displaying normal operation and maintenance (no troubles, supervisory, or alarms)? Location: On column above full kegs Original Comment: repair damaged fire alarm horn strobe hanging off of electrical box . Printed on 11 /212024 @ 09:41 Page 4 of 10 STATUS FAIL FAI L CODE 315.3.3 - Equipment rooms. 509.2 - Equipment access. DESCRIPTION Combustible material shall not be stored in boiler rooms, mechanical rooms, electrical equipment rooms or in fire command centers as specified in Section 508.1.5. Location: upper electrical room Original Comment: Remove storage (boxes of materials not related to electrical or fire equipment) from electrical room. Maintain 36" clearance to fire panel, transformers, and electric panel Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Location: Dry fire sprinkler riser by empty kegs Original Comment: Remove obstructions to dry riser. Maintain a minimum of 36" path to and around the dry fire sprinler riser. Suggest marking floor and installing permanent location sign above stating " Fire Sprinkler Riser " at this time but will be mandatory if found to be repeat offense. Printed on 11 /21 /2024 @ 09:41 Page 5 of 10 STATUS FAIL CODE 603.4 - Working space and clearancesclearance. DESCRIPTION A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: By Back door to coffee area across from big water tank. Original Comment: remove obstructions to electric panel LVIC. maintain a minimum of 36" clearance at all times. REPEAT VIOLATION Printed on 11 /21 /2024 @ 09:41 Page 6 of 10 STATUS CODE DESCRIPTION FAIL. 603.4 - Working space and A working space of not Working space around electrical equipment shall be clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). FAI L 603.5.2 - Application and usePower supply. Location: By Office Original Comment: remove obstructions to the electrical panel Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Location: Corner Office Desk below Chalk Signs Original Comment: Each power strip must plug directly into wall outletn not another power strip (daisy chaining). Printed on 11 /21 /2024 @ 09:41 Page 7 of 10 STATUS FAIL CODE 603.9.4 - Prohibited areas. FAIL 903.3.3 - Obstructed locations. DESCRIPTION Portable, electric space heaters shall not be operated within 3 feet (914 mm) of any combustible materials. Portable, electric space heaters shall be operated only in locations for which they are listed. Location: Office in Coffee Shop Original Comment: remove electric heater or provide documentation that it is approved for commercial use and clearances are maintained. Automatic sprinklers shall be installed with regard to obstructions that will delay activation or obstruct the water distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used. Automatic sprinklers shall be installed in or under covered kiosks, displays, booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width. Not less than a 3-foot (914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire -extinguishing system in accordance with Section 904. Location: walk in cooler Original Comment: remove obstructions to fire sprinkler head. Install head guard. Really close to being knocked off today. Printed on 11 /21 /2024 @ 09:41 Page 8 of 10 STATUS FAIL CODE 906.6 - Unobstructed and unobscured. GENERAL NOTES JEFF SIEBEL - 11/21/2024 @ 09:40 JEFF SIEBEL - 11/21/2024 @ 09:41 REINSPECTION DATE 12/10/2024 DESCRIPTION Portable fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. Location: By empty kegs Original Comment: remove obstructions . maintain a minimum of 36" clearance at all times. Annual inspection $100 kitchen hood cleaning due 12/12/24 Printed on 11/21/2024 @ 09:41 Page 9 of 10 CONTACT SIGNATURE Alex Hottle Signed on: 11/21/2024 @ 09:39 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 11/21/2024 @ 09:39 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 11 /21 /2024 @ 09:41 Page 10 of 10