Loading...
HomeMy WebLinkAbout1422 FLAMMANG DR., 0 v • 0 Customer #: 4706 HY-VEE #3 1422 FLAMMANG DR WATERLOO, IA 50702 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 12/16/2024 01/20/2025 2025-00000223 $235.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1422 FLAMMANG DR - 12-12-24 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 50,000 OCCUPANCY FEE Total Price J $225.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 4706 12/16/2024 01/20/2025 2025-00000223 $235.00 Less Prepayment Total Due —> City of Waterloo $0.00 $235.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT HY.VEE,1422 FLAMMANG DR, BLDG 1422 FLAMMANG DR, WATERLOO /A 50702 DETAILS Inspection Date: 12/12/2024 I Inspection Type: Annual Inspection (1Yr) ( Inspection Number: 13783 I Shift: N/A I Station: N/A Unit: N/A ; Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A I Fee: $235.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 32 I Violations: 24 N/A Codes: 28 STATUS CODE DESCRIPTION FAIL 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. FAIL 1032.2 - Reliability. Location: Back door from Liquor store Original Comment: remove obstructions to exit . maintain clear path. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Location: Office back exit (upper) Original Comment: remove obstructions, remove all storage as signed. Printed on 12/13/2024 @ 15:41 Page 1 of 13 STATUS FAI L CODE 1203.4.3 - Records. DESCRIPTION Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. Location: Bi-annual generator load bank test Original Comment: Provide current Bi-annual generator load bank test and monthly maintenance/testing log for emergency generator. May be emailed to fire inspector. FAIL 1203.4.3 - Records. Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. Location: Entire Store emergency egress/exit lights including ceiling in main store Original Comment: Provide documentation of testing and repair of all emergency lighting with signature and date. Printed on 12/13/2024 @ 15:41 Page 2 of 13 STATUS CODE DESCRIPTION FAIL 316.3 - Pitfalls. The intentional design or alteration of buildings to disable, injure, maim or kill intruders is prohibited. A person shall not install and use firearms, sharp or pointed objects, razor wire, explosives, flammable or combustible liquid containers, or dispensers containing highly toxic, toxic, irritant or other hazardous materials in a manner that could passively or actively disable, injure, maim or kill a fire fighter who forcibly enters a building for the purpose of controlling or extinguishing a fire, rescuing trapped occupants or rendering other emergency assistance. FAI L 5.2.1.1.5 - Missing escutcheons Location: Loft storage Original Comment: Install safety chain across opening with drop off. Chain should be visable (maybe sign in middle). REPEAT VIOLATION. The gates are left open frequently and creates a fall risk for employees and rescue personnel during an emergency. Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall be replaced if found missing during the inspection. Location: Bakery Freezer Original Comment: Replace missing eschutcheon and missing moisture proof light cover. Printed on 12/13/2024 @ 15:41 Page 3 of 13 STATUS FAI L CODE 5303.5.3 - Securing compressed gas containers, cylinders and tanks. DESCRIPTION Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Location: Generator room Original Comment: Properly secure compressed gas cylinders with chain to prevent tip over. Remove propane tank from building. Printed on 12/13/2024 @ 15:41 Page 4 of 13 STATUS FAI L CODE DESCRIPTION 603.2 - Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions and electrical conditions in permanent wiring shall be brought to the attention of the hazards. responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Location: Meat walk in freezer Original Comment: repair light fixtures hanging from ceiling . FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Liquor back room Original Comment: remove obstructions from electric panel. maintain a minimum of 36" clearance. Printed on 12/13/2024 @ 15:41 Page 5 of 13 STATUS FAI L CODE 603.4 - Working space and clearancesclearance. DESCRIPTION A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Behind asian restaurant Original Comment: Remove obstructions to electric panels . maintain a minimum of 36" clearance. Panels already labeled Printed on 12/13/2024 @ 15:41 Page 6 of 13 STATUS CODE DESCRIPTION FAIL 603.4.1 - Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. The disconnecting means for each service, feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident. Where buildings or structures are supplied by more than one power source, markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. FAI L 603.5 - Relocatable power taps and current taps.Multiplug adapters. Location: Electrical room by upstairs offices Original Comment: Install permanent sign stating "Electrical Room" Laminated paper is not acceptable. Remove obstructions to electrical panel and maintain a minimum of 36" clearance at all times. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: Cooler by desk in grocery pick-up Original Comment: cooler must plug directly into permanent wall outlet. Printed on 12/13/2024 @ 15:41 Page 7 of 13 STATUS CODE DESCRIPTION FAIL 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. FAIL 603.9.4 - Prohibited areas. Location: employee breakroom Original Comment: remove extension cord from TV. A power tap wth a manual reset may be used for TV. Portable, electric space heaters shall not be operated within 3 feet (914 mm) of any combustible materials. Portable, electric space heaters shall be operated only in locations for which they are listed. Location: Flower department Original Comment: remove electric heater. FAIL 603.9.4 - Prohibited areas. Portable, electric space heaters shall not be operated within 3 feet (914 mm) of any combustible materials. Portable, electric space heaters shall be operated only in locations for which they are listed. Location: Liquor check out Original Comment: remove electric heater Printed on 12/13/2024 @ 15:41 Page 8 of 13 STATUS CODE DESCRIPTION FAIL 603.9.4 - Prohibited areas. Portable, electric space heaters shall not be operated within 3 feet (914 mm) of any combustible materials. Portable, electric space heaters shall be operated only in locations for which they are listed. FAIL FAI L Location: Starbucks coffee Original Comment: remove electric heater. 606.1 - General. Commercial kitchen exhaust hoods shall comply with the requirements of the International Mechanical Code . Location: Main Kitchen hood Original Comment: Fryer is not under hood at least 6 inches , extending out beyond fire and exhaust coverage. Relocate 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: Kitchen food fire suppression system Original Comment: Provide current kitchen hood fire suppression system report with all discrepancies corrected. Contractor must upload report online to the compliance engine. Currently 90 days past due Printed on 12/13/2024 @ 15:41 Page 9 of 13 STATUS CODE DESCRIPTION FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: Kitchen hood cleaning inspection Original Comment: Provide current kitchen hood exhaust system cleaning report with all discrepancies corrected. Contractor must upload report online to the compliance engine. Currently 98 days past due FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1 Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: above 3 compartment sink in meat department Original Comment: replace missing ceiling tile Printed on 12/13/2024 @ 15:41 Page 10 of 13 STATUS CODE DESCRIPTION FAIL 705.2 - Inspection and Opening protectives in fire -resistance -rated assemblies shall be inspected and maintenance. maintained in accordance with NFPA 80. Opening protectives in smoke barriers shall be inspected and maintained in accordance with NFPA 80 and NFPA 105. Openings in smoke partitions shall be inspected and maintained in accordance with NFPA 105. Fire doors and smoke and draft control doors shall not be blocked, obstructed, or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Opening protectives and smoke and draft control doors shall not be modified. FAI L Location: By fruit cut-up room Original Comment: Fire Drop door is obstructed and will not function as designed. remove obstructions and mark floor with red tape 904.13.5.1 - Existing Where changes in the cooking media, positioning of cooking equipment or automatic fire -extinguishing replacement of cooking equipment occur in existing commercial cooking systems. systems, the automatic fire -extinguishing system shall be required to comply with the applicable provisions of Sections 904.13 through 904.13.4. Location: asian kitchen Original Comment: Equiptment appears to be rearanged , moving cooktop out of suppression design area. re -align equipment or have certified by design professional Printed on 12/13/2024 @ 15:41 Page 11 of 13 STATUS CODE DESCRIPTION FAIL 906.6 - Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view. In unobscured. rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. FAI L 906.6 - Unobstructed and unobscured. Location: Beside dairy cooler Original Comment: remove obstructions. maintain a minimum of 36" clearance at all times. Portable fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. Location: By frozen dinners Original Comment: Remove obstructions to fire extinguishers. Maintain a minimum of 36" clearance at all times. GENERAL NOTES JEFF SIEBEL - 12/13/2024 @ 15:35 Annual fire inspection fee $235 Printed an 12/13/2024 @ 15:41 Page 12 of 13 REINSPECTION DATE 01/23/2025 CONTACT SIGNATURE Lucas Signed on: 12/13/2024 @ 15:38 �2c �GJ L� INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 12/13/2024 @ 15:38 QUESTIONSA/OUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 12/13/2024 @ 15:41 Page 13 of 13