Loading...
HomeMy WebLinkAbout1956 LAFAYETTE STCustomer #: 3312 CORK'S GROCERY 1956 LAFAYETTE ST WATERLOO, IA 50703 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 12/16/2024 01/20/2025 2025-00000221 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1956 LAFAYETTE ST - 12-9-24 [ Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 2,000 OCCUPANCY FEE Total Price ] $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 3312 12/16/2024 01/20/2025 2025-00000221 $80.00 Less Prepayment Total Due City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT CORK'S GROCERY, 1956 LAFAYETTE ST, BLDG 1956 LAFAYETTE ST, WATERLOO IA 50703 DETAILS Inspection Date: 12/09/2024 ( Inspection Type: Annual Inspection (1Yr) I Inspection Number: 11669 ( Shift: N/A I Station: N/A Unit: N/A ( Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A I Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 ( Passed Codes: 24 I Violations: 4 I N/A Codes: 47 STATUS CODE DESCRIPTION FAIL FAIL 603.5 - Relocatable power taps and current taps.Multiplug adapters. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: Behind red bull and coke coolers and horizontal freezers Original Comment: remove power strip. Freezers and coolers must plug directly into permanent outlet. Install permanent outlet with permits and inspections. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: Behind pepsi/coke machines at end of aisle Original Comment: remove multi -plug adapter . Coolers must plug directly into permanent wall outlet. Install permanent outlet with proper permits and inspections. Printed on 12/10/2024 @ 09:36 Page 1 of 4 STATUS FAIL CODE 603.6 - Extension cords. DESCRIPTION Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: between pepsi cooler and uupright freezer. Original Comment: remove extension cord. Freezers and coolers must plug directly into permanent outlet. Install permanent outlet with permits and inspections. Printed on 12/10/2024 @ 09:36 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Not Provided Original Comment: provide annual service for fire extinguishers GENERAL NOTES JEFF SIEBEL - 12/10/2024 @ 09:36 annual inspection $80 REINSPECTION DATE 01/06/2025 CONTACT SIGNATURE Jasmine Jasmeen Signed on: 12/10/2024 @ 09:26 Printed on 12/10/2024 @ 09:36 Page 3 of 4 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 12/10/2024 @ 09:28 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 12/10/2024 @ 0036 Page 4 of 4