Loading...
HomeMy WebLinkAbout1850 W RIDGEWAY AVE0 lV INVOICE DATE DUE DATE INVOICE # TOTAL DUE 12/19/2024 01/25/2025 2025-00000226 $80.00 Customer #: 14477 WATERLOO GOLF HEADQUARTERS 1850 WEST RIDGEWAY, SUITE 1 WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1850 W RIDGEWAY AVE - 12-16-24 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price J $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 14477 12/19/2024 01/25/2025 2025-00000226 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT NULL, GOLF HEADQUARTERS, 1350 W RIDGEWAYAVE, BLDG 14150 W RIDGEWAYAVE - STE 1, WATERLOO IA 50701 DETAILS Inspection Date: 12/16/2024 1 Inspection Type: Annual Inspection (1Yr) 1 Inspection Number: 11643 ( Shift: N/A 1 Station: N/A I Unit: N/A I Lead Inspector: JEFF SIEBEL 1 Other Inspectors: N/A I Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 38 I Violations: 3 I N/A Codes: 33 STATUS CODE DESCRIPTION FAIL 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Mikes office Original Comment: remove white extension cord. Power strip with manual reset can be used for small electronics , computers, TV's when plugged directly into wall outlet and properly supported. Printed on 12/17/2024 @ 09:48 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 606.2 - Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Exceptions: 1.Factory-built commercial exhaust hoods that are listed and labeled in accordance with UL 710, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2.Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 710B, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code. For the purpose of determining the floor area required to be ventilated, each individual appliance shall be considered as occupying not less than 100 square feet (9.3 m2). 3.Where cooking appliances are equipped with integral down -draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96, a hood shall not be required at or above them. 4.A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mg/m3 or less of grease when tested at an exhaust flow rate of 500 cfm (0.236 m3/s) in accordance with UL 710B. Location: Kitchen Original Comment: Remove air fryer or install type one hood with fire suppression. Grease laden vapors are still produced. Printed on 12/17/2024 @ 09:48 Page 2 of 4 STATUS CODE DESCRIPTION 906.2 - General requirements. GENERAL NOTES Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Kitchen Original Comment: Provide annual service for fire extinguisher and remove obstructions. Maintain a minimum of 36" clearance at all times. JEFF SIEBEL - 12/17/2024 @ 09:38 Annual inspection $80 REINSPECTION DATE 01/23/2025 CONTACT SIGNATURE Michael Schuchmann Signed on: 12/17/2024 @ 09:45 Printed on 12/17/2024 @ 09:48 Page 3 of 4 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 12/17/2024 @ 09:45 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 12/17/2024 @ 09:a Page 4 of 4