COMMERCIAL INSPECTION - 2034 LAPORTE RD - 12-2-24
[ Description
FOR BILLING INQUIRY: (319)291-4323
INSPECTION 50,000
OCCUPANCY FEE
Total Price ]
$225.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
12855
12/19/2024
01/25/2025
2025-00000234
$235.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$235.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
HAMPTON INN & SUITES, 2034 LA PORTE RD, BLDG 2034 LA PORTE RD, WATERLOO IA 50702
DETAILS
Inspection Date: 12/02/2024 I Inspection Type: Annual Inspection (1Yr) ( Inspection Number: 13671 Shift: N/A j Station: N/A j
Unit: N/A j Lead Inspector: JEFF SIEBEL ; Other Inspectors: N/A I Fee: $235.00
VIOLATIONS AND COMPLIANCES
Showing only violations and images for this inspection. Please reach out to the lead inspector for more details.
Resolved Violations: 0 I Passed Codes: 35 ( Violations: 49 N/A Codes: 26
STATUS CODE DESCRIPTION
FAIL 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously
maintained free from obstructions or impediments to full instant use in the case
of fire or other emergency where the building area served by the means of
egress is occupied. An exit or exit passageway shall not be used for any purpose
that interferes with a means of egress.
Location: 1st floor east stair outside exit door
Original Comment: REPEAT OFFENSE remove garbage can, blocking fire exit. Install
permanent signage stating " Fire Exit Do Not Block".
FAIL 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously
maintained free from obstructions or impediments to full instant use in the case
of fire or other emergency where the building area served by the means of
egress is occupied. An exit or exit passageway shall not be used for any purpose
that interferes with a means of egress.
Location: Outside exit door west side stairs
Original Comment: Door obstructed by rock -could not open
Printed on 12/04/2024 @ 10:15
Page 1 of 18
STATUS CODE DESCRIPTION
FAIL 1103.9 - Carbon monoxide Carbon monoxide alarms detection shall be installed in existing dwelling units
alarmsdetection. and sleeping units Group 1-1, 1-2, 1-4 and R occupancies and in classrooms in
Group E occupancies where those units include any of the conditions identified in
Sections 915.1.2 through 915.1.6. The carbon monoxide alarms shall be installed
in the locations specified in Section 915.2 and the installation shall be in
accordance with Section 915.4. Exceptions: 1.Carbon monoxide alarms are
permitted to be solely battery operated where the code that was in effect at the
time of construction did not require carbon monoxide detectors to be provided.
2.Carbon monoxide alarms are permitted to be solely battery operated in
dwelling units that are not served from a commercial power source. 3.A carbon
monoxide detection system in accordance with Section 915.5 shall be an
acceptable alternative to carbon monoxide alarms.
Location: Laundry Room AHU
Original Comment: Replace missing CO detector.
FAIL 1103.9 - Carbon monoxide Carbon monoxide alarms detection shall be installed in existing dwelling units
alarmsdetection. and sleeping units Group 1-1, 1-2, 1-4 and R occupancies and in classrooms in
Group E occupancies where those units include any of the conditions identified in
Sections 915.1.2 through 915.1.6. The carbon monoxide alarms shall be installed
in the locations specified in Section 915.2 and the installation shall be in
accordance with Section 915.4. Exceptions: 1.Carbon monoxide alarms are
permitted to be solely battery operated where the code that was in effect at the
time of construction did not require carbon monoxide detectors to be provided.
2.Carbon monoxide alarms are permitted to be solely battery operated in
dwelling units that are not served from a commercial power source. 3.A carbon
monoxide detection system in accordance with Section 915.5 shall be an
acceptable alternative to carbon monoxide alarms.
Location: Above fire place in lobby
Original Comment: CO detector does not function. Repair or replace if
manufactured over 10 years ago.
FAI L 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.
The system shall be capable of powering the required load for a duration of not
less than 90 minutes.
Location: 3rd Floor West by storage room/stairs
Original Comment: repair upper exit light. Must illuminate at all times.
Printed on 12/04/2024 @ 10:15
Page 2 of 18
STATUS CODE DESCRIPTION
FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.
The system shall be capable of powering the required load for a duration of not
less than 90 minutes.
FAI L
FAIL
FAI L
Location: Second floor by East stairs
Original Comment: /Repair. Exit sign hanging by wires.
2015 IFC - Fire alarm testing Is the fire alarm system powered, operational and displaying normal operation
and maintenance (no troubles, supervisory, or alarms)?
Location: Room 128
Original Comment: repair smoke detector. Smoke detector and lights hanging by
wires.
5.2.1 - Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor
system inspection
Location: Annual Fire Sprinkler Deficiency
Original Comment: Provide current annual fire sprinkler report with all
discrepancies corrected. Current report lists deficiencies . Contractor must
upload corrections online to the compliance engine.
5.2.1 - Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor
system inspection
Location: Annual Standpipe insepction deficiencies
Original Comment: Provide current annual fire sprinkler stand pipe inspection
report wth all discrepancies corrected. Current report lists 2 discrepancies.
Contractor must upload corrections online to the compliance engine.
Printed on 12/04/2024 10:15
Page 3 of 18
STATUS CODE DESCRIPTION
FAI L
FAI L
FAIL
5.2.1.1.5 - Missing
escutcheons
5.2.1.1.5 - Missing
escutcheons
5.2.1.1.5 - Missing
escutcheons
Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall
be replaced if found missing during the inspection.
Location: Room 401 by bed
Original Comment: properly install escutcheon by bed. Not properly seated and
escutcheon will interfere with spray pattern.
Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall
be replaced if found missing during the inspection.
Location: Room 300
Original Comment: replace missing eschutcheon above sink
Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall
be replaced if found missing during the inspection.
Location: Bottom of West Stairs
Original Comment: remove covering from fire sprinkler head
FAIL 506.2 - Key box maintenance. The operator of the building shall immediately notify the fire code official and
provide the new key where a lock is changed or rekeyed. The key to such lock
shall be secured in the key box.
Location: KNOX BOX
Original Comment: Update fire department access keys for every space after
remodel
Printed on 12/04/2024 @ 10:15
Page 4 of 18
STATUS CODE DESCRIPTION
FAIL 507.5.3 - Private fire service Private fire service mains and water tanks shall be periodically inspected, tested
mains and water tanks. and maintained in accordance with NFPA 25 at the following intervals: 1.Private
fire hydrants of all types: Inspection annually and after each operation; flow test
and maintenance annually. 2.Fire service main piping: Inspection of exposed,
annually; flow test every 5 years. 3.Fire service main piping strainers: Inspection
and maintenance after each use. Records of inspections, testing and
maintenance shall be maintained.
Location: Private Fire Hydrant Deficiency
Original Comment: Provide current semi-annual fire hydrant inspection and
testing report with all discrepancies corrected. Current report lists deficiency.
Contractor must upload corrections online to the compliance engine.
FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be
clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment
rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts. The minimum required working space shall be not less
than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches
(1981 mm) in height shall be providedin front of electrical service equipment.
Where the electrical service equipment is wider than 30 inches (762 mm), the
minimum working space shall be not less than the width of the equipment.
Storage of materials shall not be located within the designated working space.
Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2.
Access openings into attics or under -floor areas that provide a minimum clear
opening of 22 inches (559 mm) by 30 inches (762 mm).
Location: 3rd floor west storage room
Original Comment: remove obstructions to electrical panel. Maintain a minimum
of 36" clearance at all times.
Printed an 12/04/2024 @ 10:15
Page 5 of 18
STATUS CODE DESCRIPTION
FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be
clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment
rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts. The minimum required working space shall be not less
than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches
(1981 mm) in height shall be providedin front of electrical service equipment.
Where the electrical service equipment is wider than 30 inches (762 mm), the
minimum working space shall be not less than the width of the equipment.
Storage of materials shall not be located within the designated working space.
Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2.
Access openings into attics or under -floor areas that provide a minimum dear
opening of 22 inches (559 mm) by 30 inches (762 mm).
Location: West Vending room
Original Comment: remove obstructions to electric panel. Maintain a minimum of
36" clearance to and around panel and electrical equipment.
FAIL 610.1.2 - Maintenance. The lint trap, mechanical and heating components, and the exhaust duct system
of a clothes dryer shall be maintained in accordance with the manufacturer's
operating instructions to prevent the accumulation of lint or debris that prevents
the exhaust of air and products of combustion.
Location: Commercial and Guest Dryers
Original Comment: Provide current documentation of dryer vent cleaning to the
outside of the building.
Printed on 12/04/2024 @ 10:15
Page 6 of 18
STATUS CODE DESCRIPTION
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: Entire second floor guest fire doors
Original Comment: Install approved smoke seal in all fire door openings that has
been removed including stair doors and utility areas. Check all other floors
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1 Joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: 306
Original Comment: Repair fire door. Door must completely seal on all sides.
Currently gap across the top.
Printed on 12/04/2024 @ 10:15
Page 7 of 18
STATUS CODE DESCRIPTION
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1 Joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: Entire 4th Floor Fire Doors
Original Comment: Repair or replace fire doors that are improperly installed.
Doors must seal all sides including top and botom to prevent smoke/fire from
inflitrating fire rated coridoor.
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: 1st Floor Main Electrical Room
Original Comment: Fire door propped open. Must remain closed at all times.
Printed on 12/04/2024 @ 10:15
Page 8 of 18
STATUS CODE DESCRIPTION
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1.joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: Stairway Fire Door by room 330
Original Comment: Repair fire door. There is a gap at bottom of door. Must
completely seal
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1 Joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: 3rd Floor Elevator Fire Door
Original Comment: Fire door must completely self -close and latch
Printed on 12/04/2024 @ 10:15
Page 9 of 18
STATUS CODE DESCRIPTION
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: 3rd Floor ice machine room
Original Comment: replace missing ceiling tile
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1.joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: 1st floor hall and rooms
Original Comment: replace missing ceiling tiles.
Printed on 12/04/2024 @ 10:15
Page 10 of 18
STATUS CODE DESCRIPTION
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: 1st floor East Stair door
Original Comment: replace/repair smoke seals.
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1.joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: Maintenance Office
Original Comment: Patch the sheetrock ceiling and mud and tape
Printed on 12/04/2024 @ 10:15
Page 11 of 18
STATUS CODE DESCRIPTION
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1 Joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: Guest Computer Room
Original Comment: patch sheetrock ceiling with sheetrock. Mud and tape joints.
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1 Joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: IT equipment room in offices
Original Comment: replace missing ceiling tiles.
Printed on 12/04/2024 @ 10:15
Page 12 of 18
STATUS CODE DESCRIPTION
FAIL 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch
automatically.
FAI L
FAI L
FAI L
Location: Main Office
Original Comment: All doors with a fire door rating label must completely self -
close and latch.
705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch
automatically.
Location: Room 311
Original Comment: Fire door must completely self -close and latch
705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch
automatically.
Location: Room 323 Fire Door
Original Comment: Fire door must completely self -close and latch.
705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch
automatically.
Location: Room 319 Fire Door and smoke detector
Original Comment: Fire door must completely self -close and latch. Smoke
detector not working
Printed on 12/04/2024 @ 10:15
Page 13 of 18
STATUS CODE DESCRIPTION
FAIL 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch
automatically.
Location: 4th Floor laundry chute
Original Comment: Laundry chute door must completely self -close and latch.
FAI L
FAI L
FAI L
705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch
automatically.
Location: 4th Floor Elevator Fire Door
Original Comment: fire door must completely self -close and latch.
705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch
automatically.
Location: West 3rd floor storage room fire door
Original Comment: repair door. Fire Door must completely self -close and latch
705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch
automatically.
Location: 3rd Floor West stair fire door
Original Comment: Repair door. Fire door must completly self -close and latch.
Printed on 12/04/2024 @ 10:15
Page 14 of 18
STATUS CODE DESCRIPTION
FAIL 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch
automatically.
FAI L
FAI L
FAI L
Location: Room 228
Original Comment: fire door must completely self -close and latch. uncover smoke
detector.
705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch
automatically.
Location: 2nd Floor East Electrical Room
Original Comment: Repair door .Inside fire door must completly self -close and
latch. Repair smoke seal
705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch
automatically.
Location: 2nd Floor laundry inside door
Original Comment: Repair fire door. Fire door must completely self -close and
latch. Upper part of door does not properly seal.
705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch
automatically.
Location: Room 202
Original Comment: repair door . Fire door must completely self -close and latch.
Printed on 12/04/2024 @ 10:15
Page 15 of 18
STATUS CODE DESCRIPTION
FAIL 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch
automatically.
FAI L
FAI L
Location: Room 208
Original Comment: Fire door must completely self -close and latch. The door is
also not currently sealing correctly. Door must completly seal.
705.2.4 - Door operation. Swinging fire doors shall dose from the full -open position and latch
automatically.
Location: Both 2nd Floor elevator Fire doors
Original Comment: Repair doors. Fire doors must complety self -close and latch.
705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch
automatically.
Location: 2nd floor laundry chute room
Original Comment: repair fire door. Fire door must completely self close and
latch. remove obstructions to electric panel. Maintain a minimum of 36"
clearance.
FAIL 903.3.3 - Obstructed Automatic sprinklers shall be installed with regard to obstructions that will delay
locations. activation or obstruct the water distribution pattern and shall be in accordance
with the applicable automatic sprinkler system standard that is being used.
Automatic sprinklers shall be installed in or under covered kiosks, displays,
booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width.
Not less than a 3-foot (914 mm) clearance shall be maintained between
automatic sprinklers and the top of piles of combustible fibers. Exception:
Kitchen equipment under exhaust hoods protected with a fire -extinguishing
system in accordance with Section 904.
Location: Remodel Areas
Original Comment: Uncover all fire sprinkler heads unless area is actively being
worked on .
Printed an 12/04/2024 @ 10:15
Page 16 of 18
STATUS CODE DESCRIPTION
FAIL Chapter 14 - Inspection, Fire alarm system tested at least annually by licensed contractor
testing, and maintenance
FAI L
FAI L
FAI L
Location: Room 414 Smoke Detector
Original Comment: Repair/replace smoke detector not funtioning. Verify
manufacturer date. Replace if over 10 years old.
Chapter 14 - Inspection, Fire alarm system tested at least annually by licensed contractor
testing, and maintenance
Location: Annual Fire Alarm Inspection
Original Comment: Provide current semi-annual fire alarm inspection report with
all discrepancies corrected. Currently 106 days past due. Contractor must upload
online to the compliance engine.
Chapter 14 - Inspection, Fire alarm system tested at least annually by licensed contractor
testing, and maintenance
Location: All of first floor halls and rooms including west vending and kitchen
Original Comment: Remove all smoke detector covers and covering . Must be
uncovered at all times unless immediate area is actively being worked on.
Chapter 14 - Inspection, Fire alarm system tested at least annually by licensed contractor
testing, and maintenance
Location: Room 319 Smoke Detector and door
Original Comment: Repair or replace smoke detector in room not funtioning.
Verify Smoke detector manufacturer date. Detectors over 10 years old must be
replaced or sensitivety tested. Fire door not completely self -closing and latching.
GENERAL NOTES
Printed on 12/04/2024 @ 10:15
Page 17 of 18
JEFF SIEBEL - 12/04/2024 @ 10:11 Annual inspection $235
REINSPECTION DATE
01/14/2025
CONTACT SIGNATURE
Mitch Goodrich - Maintenance
Signed on: 12/04/2024 @ 10:12
Ktc. --c/J-7›-
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on: 12/04/2024 @ 10:12
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 12/04/2024 @ 10:15