RENTAL INSPECTION - 1133 DIXON DR - 5-24-26
FOR BILLING INQUIRY: (319)291-4323
[ Description
Total Price ]
REINSPECTION FEE 2ND
$150.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24076
06/21/2023
07/25/2023
2023-00020441
$150.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$150.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
'4 P4
1125-1133 DIXON DRIVE CONDOMINIUMS BLDG, 1133 DIXON DR, WATERLOO IA S0701
DETAILS
Inspection Date: 05/24/2023 I Inspection Type: Rental Inspection j Inspection Number: 10114 j Shift: N/A I Station: N/A !,
Unit: N/A I Lead Inspector: BARRY STRATTON j Other Inspectors: N/A I Fee: $150.00 id
41/ '6, -7s1°
STATUS CODE DESCRIPTION
FAIL 1008.1 - Means of egress Illumination shall be provided in the means of egress in accordance with Section
illumination. 1008.2. Under emergency power, means of egress illumination shall comply with
Section 1008.3.
Inspector: BARRY STRATTON - Comments: Egress lighting does not work. Today's
inspections lights still do not work.
Location: Not Provided
FAIL 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied. An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector: BARRY STRATTON - Comments: Front door threshold is obstructing door
from closing. Threshold is still not repaired.
Location: Not Provided
FAIL 603.2 - Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring, devices, appliances and other equipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not be used.
Inspector: BARRY STRATTON - Comments: AC disconnect box on East side of building
is hanging by wires. Box needs secured to building. AC disconnect box still hanging
from building. Today's inspection one deck screw held box to siding. When checking
box it pulled off screw.
Location: Not Provided
Fr•nteC on O5.12412023 t_:' .
Page 1 of 4
FAIL
704.3 Opening p/oc ncives.
9O1.6'Inspection, testing and
maintenance.
Where openings are required noheprotected, opening p/utecdvesshall be
maintained self -closing or auto rnatic-cl osing by smoke detection. Existing fusible-link-
typeauVzmadcdoor'dosin8device»arepermitteUif(hefo»ib|e1inkradnQdoesnot
exceed 135^F(57"O.
Inspector: BARRY5TKATT0N Comments: Fire doors inopen position. Fire doors still
left in the open position on todays inspection, may require door closures installed on
doors.
Location: Not Provided
Fire detection and alarm sys ems,eme,gencya!a/msystems, gas detection systems,
fire -extinguishing systems, mechanical smoke exhaust systems and smoke and heat
vents protection and life safety systems shall be maintained in an operative condition
at all times, and shall be replaced or repaired where defective. Nonrequired fire
protection and life safety systems and equipment shall be inspected, tested and
maintained orremoved inaccordance with Section 9O1.8.
Inspector: B4RRY3TRATT0N Comments: Alarm need maintenance and testing.
Alarm testing still requires tested.
Location: Not Provided
Printe"on 051241.1023 (��`2:45
Page om4
STATUS coot mfScmpnom
FAIL 9061 Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.111 new
and existing Group A, E\E'FH'|.M. R'1.R-Z.R-4and 5occupancies. Exceptions: 1.10
Group R-2 Occupancies, portable fire extinguishers shall be required only in locations
specified in Iterns 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minirnurn rating of 1-A:1 D-B:C. 2.In Group E occupancies,
portable fire extinguishers shall be required only in locations specified in Items 2
through 6where each classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-8:C. 3. In storage areas of Group S occupancies where
furk|ift, powered industrial truck orpowered cart operators are the primary
occupants, fixed extinguishers, asspecified inNFPA10,shall not berequired where in
accordance with all of the following: 3.1. Use of vehicle-i-nounted extinguishers shall
boapproved bythe fire code official. I2.Each vehicle shall beequipped with a1O'
pound'40A:80B�{exhnguishe/aMixedtothevehideusingamounhngbeckes
approved by the extinguisher manufacturer or the fire code official for vehicular use.
llNot less than two spare extinguishers o/equal orgreater rating shall beavailable
on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in
the proper operation, use and inspection ofextinguishers. l5.Inspections ofvehicle-
mounted eminguisheoohaUbepedo/meddai|y.2.YVithin3Ofeet(9144mm)dismnce
of travel from commercial cooking equipment and from domestic cooking equipment
in Group 1-1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.1n areas where
flammable or combustible liquids are stored, used or dispensed. 4.On each floor of
structures under construction, except Group R-3 occupancies, ill accordance with
Section 3316.1. 5.YVhee required bythe sections indicated inTable 900.1. 0.Specia|'
haza/dareas. including but not limited to laboratories, computer rooms and
generator rooms, where required by the fire code official. Exception: Portable fire
extinguishers are not required at normally unmanned Group U occupancy buildings
or structures where a portable fire extinguisher suitable to the hazard of the location
isprovided onthe vehicle ofvisiting personnel.
R4 - Exterior Property Areas
Inspector: 8ARRYSTRATT0N Comments: Fire Extinguishers need updated. (2021).
Fire extinguishers still out of date (2021).
Location: Not Provided
|sthe exterior property area maintained inaclean, safe, and sanitary condition? This
includes grading and drainage, sidewalks and driveways, weeds, and pest
infestations. (|PM{3OZ)
Inspector: 84RRY5TKATT0N Comments: Front concrete slab ardoor. Busted
concrete missing that is under slab. Concrete slab still broken and needs repaired.
Location: Not Provided
FAIL K0 Interior Structure Has the interior ofthe structure and equipment inside been maintained ingood
repair, structurally sound, and inasanitary condition? (|PM[]05)
GENE&ALmOTES
Inspector: BARRYSTRATT0m Comments: Egress lights, fire extinguishers, fire doors,
front door threshold.
Location: Not Provided
mnteoon 05124,2r23 1 45
Page 3of^
• •
BARRY STRATTON - 05/24/2023 @ 12:42 RP complaining of terrible smell in unit # 1. Upon investigation nobody was at unit # 1
so entry was not made. Smell in building was consistent with cooking/frying.
BARRY STRATTON - 05/24/2023 @ 12:43 Photos obtained of AC disconnect, lights not working and front landing condition.
REINSPECTION DATE
06/27/2023
CONTACT SIGNATURE
Caliber Group
Signed on: 05/24/2023 @ 12:43
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on: 05/24/2023 @ 12:43