Loading...
HomeMy WebLinkAbout212 IRVING STWq 0 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 06/21/2023 07/25/2023 2023-00020444 $250.00 Customer #: 24033 IA INVESTMENT PROPERTY 5001 1ST AVE SE SUITE 105,221 CEDAR RAPIDS, IA 52402 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 212 IRVING ST - 5-25-23 FOR BILLING INQUIRY: (319)291-4323 Description REINSPECTION FEE 3RD Total Price ] $250.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24033 06/21/2023 07/25/2023 2023-00020444 $250.00 Less Prepayment Total Due —> City of Waterloo $0.00 $250.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT IA INVESTMENT PROPERTIES LLC, 212 IRVING ST, WATERLOO IA 50703 DETAILS Inspection Date: 05/25/2023 j Inspection Type: Rental Inspection { Inspection Number: 10109 j Shift: N/A { Station: N/A Unit: N/A j Lead Inspector: BARRY STRATTON j Other Inspectors: N/A j Fee: $250.00 '#// STATUS CODE DESCRIPTION FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON - Comments: Front door needs replaced. Security hardware damaged and does not work. Location: Not Provided FAIL 1031.7 - Emergency escape Required emergency escape and rescue openings shall be maintained in accordance and rescue openings with the code in effect at the time of construction, and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector: BARRY STRATTON - Comments: Windows broken Location: Not Provided FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not he used. Inspector: BARRY STRATTON - Comments: Outlets covers missing, outlets pulling out of walls Location: Not Provided Printed on 05/2512023 G° q 025 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 9061 Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A,��F,H'1, M.R'1.R-2'R-4 and Soccupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in|temsZthrough 0where each dwelling unit isprovided with aportable fire extinguisher having a minimum rating nf1`A: 1O'8:[. 2.Within 3Ofeet (9144mm) ofcomme/daicooking equipment. I|nareas where flammable o/combustible liquids are stored, used ordispensed. 4. Oneach floor ofstructures under construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required bythe sections indicated inTable 9061.0. Specia|'hazardaae»' including but not limited to laboratories, computer rooms and generator 1,00111s, where required bythe fire code official. FAIL 9072.11 Single- and multiple -station smoke alarms Inspector: BARRYSTRATTON'Comments: None Location: Not Provided Listed single- and multiple- station smoke alarms complying with UL217shall be installed in accordance with Sections 907,211.1 through 907.2.11.6 and NFPA 72. Inspector: 8ARRYSTRATT0N Comments: Smoke detectors needed ineach bedpnom and in basement also outside of bedrooms. Location: Not Provided FAIL R1 Unsafe Soucn/ns |sthe structure found nobedangerous tothe life, health, property orsafety of either the public or Occupants of the structure? (IPMC 108.1.1) Inspector: BARRY5TRATT0N Comments: Floors and stair handrail, electric system Location: Not Provided FAIL R3'Unfit for Huxmn |sthe structure found nobefit for human occupancy according nuthe code? (|PM{ Occupancy 108.1.3) |nspeoucBARRYSTRATrON Comments: Mold and structural issues with floors Location: Not Provided FAIL R5 Exterior Structure |sthe exterior ofthe structure maintained ingood repair, Structurally Sound and sanitary state? (|PK8{304) Inspector: BARRY5TRATTON Comments: Roof leaks, front porch and stairs need Location: Not Provided FAIL R0 Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and inasanitary condition? (|PmC305) printe*=105i�5Qm`�,u:5 Page 2o[4 STATUS CODE DESCRIPTION Inspector: BARRY STRATTON - Comments: Roof Leak, ceilings in bedrooms and dining room damaged from water leak, floors damaged and need replaced throughout house, toilet needs re -set onfloor on1st floor and 2ndfloor toilet does not work, bath tub onlochas leak that runs onfloor, and sink leaks. Kitchen sink does not drain, peeling paint throughout house, door hardware missing on doors, broken windows need repaired. Handrail and balusters need replaced going upstairs. Mice Location: Not Provided FAIL ROA. Interior Structure- Were any unsafe conditions noted during the interior in»peoinn7|P&1[3D51]) Unsafe Conditions |nspeooc84RRYSTRATTON Comments: Floors unstable, porch flourandsrairs unstable Location: Not Provided FAIL mi[l Residential Heating Are dwellings provided with heating facilities capable ofmaintaining aroom temperature of68F7(|PMCOOJ.2) Inspector: BARRYSTRATT0N'Comments: Register covers missing and some not attached, gravity ducts not working and full of debris. Location: Not Provided GENERAL NOTES BARRY5TRAT[0N 05/25/2023@10:23 Failure to comply with inspection report a municipal infraction will be issued,($595-00), and arevocation ofthe rental permit. BAKRYSTRATTON 05/25Q023@10:24 BARRYSTRATTON 05/25/2023@10:24 111J}Prohibited Occupancy, Any occupied structure condemned and placarded bythe code official shall hevacated aso/deredbyrheoodeoffidaiAnypeemnwhoshaU occupyap|aca/dedpemisesorshaUoperatep|acondedequipment,andanyowne/o' owner's authorized agent who shall let anyone occupy aplacarded premises or operate placarded equipment shall be liable for the penalties provided by this code. 111.1.3 Structure unfit for human occupancy. A structure is unfit for human occupancy whenever the code official finds that such structure is unsafe, unlawful or, because of the degree towhich the structure isindisrepair orlacks maintenance, is insanitary, vermin or rat infested, contains filth and contamination, or lacks ventilation, illumination, sanitary or- heating facilities of- other essential equipment required by this code, or because the location of the structure constitutes a hazard to the Occupants of the structure ortuthe public. nmled on 05,2�,2023m1*�5 Page um4 REINSPECTION DATE 06/29/2023 CONTACT SINATURE Joyce Wood Signed on: 05/25/2023 @ 10:24 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 05/25/2023 @ 10:24 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON bat ry.strarton@waterloo-la.org (319) 231-9147 Page 4 of 4