RENTAL INSPECTION - 612 RHEY ST - 5-25-23
FOR BILLING INQUIRY: (319)291-4323
L Description
Total Price 1
REINSPECTION FEE 3RD
$250.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
23528
06/21/2023
07/25/2023
2023-00020451
$250.00
Less Prepayment
Total Due -*
City of Waterloo
$0.00
$250.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
DJS PROPERTIES LLC 3 FAMILY CONVERSION, 612 RHEY ST, WATERLOO fA
DETAILS
7
Inspection Date: 05/25/2023 Inspection Type: Rental Inspection I Inspection Number: 10122 Shift: N/A Station: N/A j
Unit: N/A l Lead Inspector: BARRY STRATTON Other Inspectors: N/A I Fee: $250.00
21-1 t SA7
STATUS CODE DESCRIPTION
FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON - Comments: Front door
Location: Not Provided
FAIL 1031.7 - Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction, and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars, grilles, grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key, tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRY STRATTON - Comments: Window sills rotten
Location: Not Provided
FAIL 605.1 - Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON - Comments: Outlets not grounded and have tension
strength issues. Outlets have grounding pins broken off in outlets. Have outlets
replaced and grounding issues corrected. Globes needed on all light. Light in living
room has exposed wires.
Location: Not Provided
Printed on 0512_12 _.: td: 103a
Page 1 of 4
STATUS CODE DESCRIPTION
906.1 - Where required
FAIL 907.2.11 Single and
mu|dp|e'soationsmokp
alarms
Portable fire extinguishers shall beinstalled inall ofthe following locations: 1.innew
and existing Group A_EL�F,H.1,M'R'tR-2'R-4and Soccupancies. Exception: in
Group R-2 Occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having aminimum rating uf1`A:10-B:[.2.Within 3Ofeet (9144mm)
ofcommercial cooking equipment. 3.|nareas where flammable orcombustible
liquids are stored, used ordispensed. 4.Oneach floor ofstructures under
construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required bythe sections indicated inTable 9Oh.1.O. Speda|'hazandareas,
including but not limited to laboratories, computer rooms and generator rooms,
where required bythe fire code official.
Location: Not Provided
Listed single- and multiple- station smoke alarms complying with UL217shall be
installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
Inspector: BARRY5TKATTON Comments: Nosmoke detectors installed inunit #1
Location: Not Provided
FAIL 915.1 General Carbon monoxide detection shaUheinstaUedinnewbui|ding»inaccordancewith
Sections 91511through 91l§.Carbon monoxide detection shall beinstalled in
existing buildings in accordance with Section 1103.9.
Inspector: 8ARRYSTRATT0N Comments: O}detectors needed
Location: Not Provided
FAIL R5 Exterior Structure Isthe exterior cfthe structure maintained ingood repair, structurally sound and
sanitary state? (IPMC 304)
Inspector: BARRY5TRATTON Comments: Front porch has supports that are failing,
Front stairs are rotten and need replaced. Holes inporch floor need corrected.
Apartment door co#1 needs replaced since door has been broken and split arlock
sets New stairs installed donot meercode.
Location: Front of building,
FAIL R5 Interior Structure Has the interior cfthe structure and equipment inside been maintained ingood
repair, structurally sound, and inasanitary condition? (|PK«[305)
��v C, 35, 1!'2C'Z3 '��,o34
Page 2or*
srAruS cuDs oeuro/pnON
inspector: 8ARRYSTRATT0N'Comments: Floors, cat -pet stained, floor has several
clips from supports inbasement failing. Holes inwalls, rotten window sills in
bedroom, screen damaged, register vents not inducts.
Location: Not Provided
FAIL RlE.'Residential Heating Are dwellings provided with heating facilities capable ofmaintaining oroom
temperature ofO8R(lPMC 602.2)
61NEXAL NOTES
8ARRYSTRATT0N 05/ 5QO23@)102J
Inspector: BARRYSTRATT0N'{ommenrsRegister covers
Location: Not Provided
]O41OStairways, decks, porches and balconies. Every exterior stainmay deck pooh
and balcony, and all appurtenances attached thereto, shall be maintained structurally
sound, iogood repair, with proper anchorage and capable ofsupporting the imposed
loads.
8ARRYSTRA7T0N 05/25/2023@1032 304.13 Window, skylight and door frames. Every window, skylight, door and frarne shall
be kept in sound condition, good repair and weather tight.
BARRY STRATT0N 05/25/2023@10:32
30415Doors. Exterior doors,doora»sembUes,opem,orsystems ifprovided, and
hardware shall bemaintained ingood condition. Locks a,all entrances mdwelling
units and sleeping units shall tightly secure the door. Locks on means of egress doors
shall heinaccordance with Section 7UZ3
BARRYSTKAlT0N 05/25/2023@10C32 305.4 Stairs and walking surfaces. Every stair, rarnp, landing, balcony, porch, deck or
other walking surface shall be maintained in sound condition and good repair
BARRYSTRATT0N 05/25/2023@10:32
BARRYSTRATTON 05/ 5QOZ3@1032
304.4 Structural members. Structural members shall bemaintained free from
deterioration, and shall be capable of safely supporting the imposed dead and live
loads.
3O53Interior surfaces, Interior surfaces, including windows and doors, shall be
maintained ingood, clean and sanitary condition. Peeling, chipping, flaking or abraded
paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood
and other defective surface conditions shall becorrected.
Printed on 05,25,Z�23-I10.34
Page 5m*
~. ~
GENERAL NOTES
BARRYSTKA7TON 05/25/2023@10:32
REINSmECTION DATE
O@Z9/202J
CONTACT SIGNATURE
Matt Matthias
INSPECTOR SIGNATURE
B4AKYSTRATTON
QUESTIONS ABOUT YOUR INSPECTION?
BARRYSTRATTON
Ua/ry.st/aruon@wanedo*ia.org
604.3 Electrical system hazards. Where it is found that the electrical system in a
structure constitutes ahazard tothe occupants o/the structure byreason uf
inadequate service, improper fUsinp, insufficient receptacle and lighting outlets,
improper wiring or installation, deterioration or damage, or for similar reasons, the
code official shall require the defects robecorrected noeliminate the hazard.