RENTAL INSPECTION - 210 INDEPENDENCE AVE - 5-16-23
FOR BILLING INQUIRY: (319)291-4323
LDescription
Total Price j
REINSPECTION FEE 3RD
$250.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
23001
06/21/2023
07/25/2023
2023-00020443
$250.00
Less Prepayment
Total Due -*
City of Waterloo
$0.00
$250.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
AMERIOO FIRE RESCUE
INSPECTION REPORT
QUALITY CONCRETE CONSTRUCTION MULTI UNIT COMPLEX, 210 INDEPENDENCE AVE,
WATERLOO IA 50703
DETAILS
Inspection Date: 05/16/2023 I Inspection Type: Rental Inspection I Inspection Number: 10063 I Shift: N/A { Station: N/A
A/ % - P,S 1°
Unit: N/A ( Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee: $250.00
STATUS CODE DESCRIPTION
FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
FAIL
1031.7 - Emergency escape
and rescue openings
Inspector: BARRY STRATTON - Comments: None
Location: Not Provided
Required emergency escape and rescue openings shall be maintained in accordance
with the code in effect at the time of construction, and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars, grilles, grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key, tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRY STRATTON - Comments: Windows need to open and close
Location: Not Provided
FAIL 605.1 - Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON - Comments: Globes missing on lights
Location: Not Provided
Printed on 05/16;1323 ' 10:58
Page 1 of 5
sruruS couE osscx/pnom
Extension cords and flexible cords shall not be a substitute for permanent wiring.
Extension cords and flexible cords shall not beaffixed tostructures, extended
through walls, ceilings or floors, or under doors or floor coverings, nor shall such
cords be subject to environmental damage or physical impact. Extension cords shall
beused only with portable appliances.
Inspector: 8ARRYSTRATTON Comments: None
Location: Not Provided
FAIL 9001 Where required Portable fire extinguishers shall beinstalled inall ofthe following locations: 1.|nnew
and existing Group A,E\E.F,H,|'K4'R'1'K-2'R-4and 3occupancies. Exception: |n
Group R-2 Occupancies, portable fire extinguishers shall be required only in locations
specified in items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having aminimumrating of1'A:10'D:C.2.Within ]Ofeet (9144mm)
ofcommercial cooking equipment. 3.|nareas where flammable o/combustible
liquids are stored, used ordispensed. 4.Oneach floor uf structures under
construction, except Group R-3 occupancies, in accordance with Section 3315.1 � 5.
Where required bythe sections indicated inTable 900J.6. Speda|'hazarda/eas.
including but not limited to laboratories, computer rooms and generator rooms,
where required bythe fire code official.
FAIL 907.211 Single- and
multiple -station smoke
alarms
Location: Not Provided
Listed single- and multiple- station smoke alarms complying with UL217shall be
installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
Inspector: BARRYSTRATT0N Comments: Smoke detectors needed inall bedrooms,
outside all bedrooms, onall levels, and inbasement.
Location: Not Provided
FAIL 9151 General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 91511through 915.6.Carbon monoxide detection shall beinstalled in
existing buildings inaccordance with Section 11C8�.
Inspector: 8ARRYSTRATTON'Comments: {0detectors needed invicinity of
bedrooms.
Location: Not Provided
P,Mted =a»e�23 --,e5Z
Page oo/5
STAIrUS CODE
1P
N
FAIL R4 Exterior Property Areas is the exterior property area maintained in a clean, safe, and sanitary condition? This
includes grading anddnainage.sidewa|ksanddrivewaysweeds,andpesc
Inspector: BARRYSTRATTON Comments: junk and debris
Location: Not Provided
FAIL R5'Exterior Structure |sthe exterior of the structure maintained ingood repair, structurally sound and
sanitary state? (|PK4[304)
FAIL R6 - Interior Structure
Inspector: BARRYSTRATT0N Comments: Handrails donot matcode front steps
and concrete steps on building need replaced.
Location: Not Provided
Has the interior ofthe structure and equipment inside been maintained ingood
repair, structurally sound, and in a sanitary condition? (IPMC 305)
Inspector: BxRRYSTRATT0N Comments: Kitchen & Dining room ceilings have water
damage. Remove all water damaged material and replace. Cockroaches need
exterminated. Kitchen floor needs replaced. Windows need to be capable of opening
and closing. Front door and screen door need repaired and be capable of closing and
latching. Toilet need re -set onbarhnnomfloor. Stove needs replaced. Kids bedroom
ceiling has holes that need corrected. Need handrails on stairs to upstairs and
basement stairs. Glass all over inside apartment.
Location: Not Provided
FAQ� RO�. wechanica|Eqiupmen« Are mechanical appliances properly installed and maintained ingood working
GENERAL NOTES
Inspector: BARRY5TRATT0N Comments: Water heater need discharge tube
Location: Not Provided
printed 0"e:e20,3 (�,u�
Page 3m,5
BARRY5TKATTON 05/10O023@10:57
BARRYSTRAlT0N 05/10/2023@10:57
111.6Tr nsferofowner hip.|r»haUbeun|awfu|forchemwne/o/anydweUingunito/
structure who has received a compliance order or upon whom a notice of violation has
been served to sell, transfer, mortgage, lease or otherwise dispose of such dwelling
unit or structure to another until the provisions of the compliance order or notice of
violation have been complied with, or until such owner or the owner's authorized
agent shall first furnish the grantee, transferee, mortgagee or lessee a true copy of any
compliance order or notice of violation issued by the code official and shall furnish to
the code official asigned and notarized statement from the grantee, transferee,
mortgagee or lessee, acknowledging the receipt of such compliance order or notice of
violation arid fully accepting the responsibility without condition for making the
corrections or repairs required by such compliance order or notice of violation.
9-7-7:INSPECTIONS REQUIRED: A - Rental Properties: Regular inspection ooall
residential rental property, including mobile homes, shall be made once every three (3)
years for compliance with the building code, property maintenance code, other
applicable codes, and this chapter. In addition to said codes and this chapter, the
housing quality standards promulgated by the United States Department of Housing
and Urban Development for use in assisted housing programs shall govern to the
extent not superseded by more stringent requirements of said codes arid this chapter,
inspections of all properties shall also be made at any time upon receipt of a complaint
or request by a tenant or owner. Any rental structure receiving two (2) complaints
regarding substantiated violations during any twelve (112) month period shall be put on
anannual inspection schedule for three (]) years following the last substantiated
BARRYSTRATTON 0516/2023@10:58 New tenants inunit Z1Owithout are-inspection for occupancy.
RE INSPECTION