Loading...
HomeMy WebLinkAbout210 INDEPENDENCE AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 06/21/2023 07/25/2023 2023-00020443 $250.00 Customer #: 23001 QUALITY CONCRETE CONTRUCTION (RENTAL) 1930 HAWTHORNE AVE #1 WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 210 INDEPENDENCE AVE - 5-16-23 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price j REINSPECTION FEE 3RD $250.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23001 06/21/2023 07/25/2023 2023-00020443 $250.00 Less Prepayment Total Due -* City of Waterloo $0.00 $250.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. AMERIOO FIRE RESCUE INSPECTION REPORT QUALITY CONCRETE CONSTRUCTION MULTI UNIT COMPLEX, 210 INDEPENDENCE AVE, WATERLOO IA 50703 DETAILS Inspection Date: 05/16/2023 I Inspection Type: Rental Inspection I Inspection Number: 10063 I Shift: N/A { Station: N/A A/ % - P,S 1° Unit: N/A ( Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee: $250.00 STATUS CODE DESCRIPTION FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. FAIL 1031.7 - Emergency escape and rescue openings Inspector: BARRY STRATTON - Comments: None Location: Not Provided Required emergency escape and rescue openings shall be maintained in accordance with the code in effect at the time of construction, and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector: BARRY STRATTON - Comments: Windows need to open and close Location: Not Provided FAIL 605.1 - Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: Globes missing on lights Location: Not Provided Printed on 05/16;1323 ' 10:58 Page 1 of 5 sruruS couE osscx/pnom Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not beaffixed tostructures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall beused only with portable appliances. Inspector: 8ARRYSTRATTON Comments: None Location: Not Provided FAIL 9001 Where required Portable fire extinguishers shall beinstalled inall ofthe following locations: 1.|nnew and existing Group A,E\E.F,H,|'K4'R'1'K-2'R-4and 3occupancies. Exception: |n Group R-2 Occupancies, portable fire extinguishers shall be required only in locations specified in items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having aminimumrating of1'A:10'D:C.2.Within ]Ofeet (9144mm) ofcommercial cooking equipment. 3.|nareas where flammable o/combustible liquids are stored, used ordispensed. 4.Oneach floor uf structures under construction, except Group R-3 occupancies, in accordance with Section 3315.1 � 5. Where required bythe sections indicated inTable 900J.6. Speda|'hazarda/eas. including but not limited to laboratories, computer rooms and generator rooms, where required bythe fire code official. FAIL 907.211 Single- and multiple -station smoke alarms Location: Not Provided Listed single- and multiple- station smoke alarms complying with UL217shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRYSTRATT0N Comments: Smoke detectors needed inall bedrooms, outside all bedrooms, onall levels, and inbasement. Location: Not Provided FAIL 9151 General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 91511through 915.6.Carbon monoxide detection shall beinstalled in existing buildings inaccordance with Section 11C8�. Inspector: 8ARRYSTRATTON'Comments: {0detectors needed invicinity of bedrooms. Location: Not Provided P,Mted =a»e�23 --,e5Z Page oo/5 STAIrUS CODE 1P N FAIL R4 Exterior Property Areas is the exterior property area maintained in a clean, safe, and sanitary condition? This includes grading anddnainage.sidewa|ksanddrivewaysweeds,andpesc Inspector: BARRYSTRATTON Comments: junk and debris Location: Not Provided FAIL R5'Exterior Structure |sthe exterior of the structure maintained ingood repair, structurally sound and sanitary state? (|PK4[304) FAIL R6 - Interior Structure Inspector: BARRYSTRATT0N Comments: Handrails donot matcode front steps and concrete steps on building need replaced. Location: Not Provided Has the interior ofthe structure and equipment inside been maintained ingood repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: BxRRYSTRATT0N Comments: Kitchen & Dining room ceilings have water damage. Remove all water damaged material and replace. Cockroaches need exterminated. Kitchen floor needs replaced. Windows need to be capable of opening and closing. Front door and screen door need repaired and be capable of closing and latching. Toilet need re -set onbarhnnomfloor. Stove needs replaced. Kids bedroom ceiling has holes that need corrected. Need handrails on stairs to upstairs and basement stairs. Glass all over inside apartment. Location: Not Provided FAQ� RO�. wechanica|Eqiupmen« Are mechanical appliances properly installed and maintained ingood working GENERAL NOTES Inspector: BARRY5TRATT0N Comments: Water heater need discharge tube Location: Not Provided printed 0"e:e20,3 (�,u� Page 3m,5 BARRY5TKATTON 05/10O023@10:57 BARRYSTRAlT0N 05/10/2023@10:57 111.6Tr nsferofowner hip.|r»haUbeun|awfu|forchemwne/o/anydweUingunito/ structure who has received a compliance order or upon whom a notice of violation has been served to sell, transfer, mortgage, lease or otherwise dispose of such dwelling unit or structure to another until the provisions of the compliance order or notice of violation have been complied with, or until such owner or the owner's authorized agent shall first furnish the grantee, transferee, mortgagee or lessee a true copy of any compliance order or notice of violation issued by the code official and shall furnish to the code official asigned and notarized statement from the grantee, transferee, mortgagee or lessee, acknowledging the receipt of such compliance order or notice of violation arid fully accepting the responsibility without condition for making the corrections or repairs required by such compliance order or notice of violation. 9-7-7:INSPECTIONS REQUIRED: A - Rental Properties: Regular inspection ooall residential rental property, including mobile homes, shall be made once every three (3) years for compliance with the building code, property maintenance code, other applicable codes, and this chapter. In addition to said codes and this chapter, the housing quality standards promulgated by the United States Department of Housing and Urban Development for use in assisted housing programs shall govern to the extent not superseded by more stringent requirements of said codes arid this chapter, inspections of all properties shall also be made at any time upon receipt of a complaint or request by a tenant or owner. Any rental structure receiving two (2) complaints regarding substantiated violations during any twelve (112) month period shall be put on anannual inspection schedule for three (]) years following the last substantiated BARRYSTRATTON 0516/2023@10:58 New tenants inunit Z1Owithout are-inspection for occupancy. RE INSPECTION 06/13/2023 CONTACT SIGNATURE Joyce Wood Signed on: O51@ZO23@10:58 INSPECTOR SIGNATURE BARRYSTlRAJTON Signed on: U5/lO/2O23@10:58 �nted or,aa,aoz�`au Page *mo QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 P,-in:ecto 05i16/2023 05..?. Page 5 of 5