Loading...
HomeMy WebLinkAbout200 INDEPENDENCE AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 06/21/2023 07/25/2023 2023-00020442 $250.00 Customer #: 23001 QUALITY CONCRETE CONTRUCTION (RENTAL) 1930 HAWTHORNE AVE #1 WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 200 INDEPENDENCE AVE - 5-16-23 FOR BILLING INQUIRY: (319)291-4323 [ Description REINSPECTION FEE 3RD Total Price j $250.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23001 06/21/2023 07/25/2023 2023-00020442 $250.00 Less Prepayment Total Due -* City of Waterloo $0.00 $250.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT QUALITY CONCRETE MULTI UNIT COMPLEX, 200 INDEPENDENCE AVE, WATERLOO 1A S0703 DETAILS Inspection Date: 05/16/2023 I Inspection Type: Rental Inspection I Inspection Number: 10062 I Shift: N/A I Station: N/A Unit: N/A I Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee: $250.00 STATUS CODE DISC 4/4 -ins° FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON - Comments: None Location: Not Provided FAIL 1031.7 - Emergency escape Required emergency escape and rescue openings shall be maintained in accordance and rescue openings with the code in effect at the time of construction, and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector: BARRY STRATTON - Comments: None Location: Not Provided FAIL 605.1 - Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or - damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: None Location: Not Provided PrI;ea ar O50 5r2023 10:55 Page 1 of 3 SnATUS CODE mcscxmr/mm 906.1 - Where required Pot -table fire extinguishers shall be installed in all of the following locations: 1. in flew and existing Group A,E, E, F,H.1,M,R'1'R-2.R-4and 5occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Iterns 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minirnurn rating of 1 -A: 1 O-B: C. 2. Within 30 feet (9144 mill) ofcommercial cooking equipment. 3.|nareas where flammable orcombustible liquids are stored, used ordispensed. 4.0neach floor ofstructures under construction, except Group R-3 Occupancies, in accordance with Section 3315.1. 5. Where required bythe sections indicated inTable 9OO1.0. Speda|'hazardarea»' including but not limited to laboratories, computer rooms and generator rooms, where required bythe fire code official. Inspector: BARRYSTRATT0N Comments: Need Fire extinguisher Location: Not Provided FAIL RO-|ntehorSoucnuo* Has the interior ofthe Structure and equipment inside been maintained ingood repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: B4RRYSTRATTON Comments: Peeling and abraded paint throughout, Kitchen sink will not drain and is still leaking. Ceiling in bedroom falling and peeling paint. Bathroom tub and shower valve needs replaced. Tub has peeling paint used in tub. Peeling paint in bathroom, bedrooms, doors, handrail busted noupstairs broken Location: Not Provided FAIL R8�. Interior Structure- Were any unsafe conditions noted during the interior inspeoion?(|Pk0[30511) Unsafe Conditions Inspector: BARRYSTRATT0N Comments: Peeling and abraded paint throughout. Kitchen sink will not drain and is still leaking. Ceiling in bedroom falling and peeling paint. Bathroom tub and shower valve needs replaced. Tub has peeling paint used in tub. Peeling paint inbathroom, bedrooms, doors, handrail busted tuupstairs broken windows. Location: Not Provided FAIL R6E\ Residential Heating Are dwellings provided with heating facilities capable ofmaintaining aroom temperature of68F?(|PMC002.2) Inspector: B4RRYSTRATT0N Comments: Register covers Location: Not Provided FAIL mlC Mechanica|Eqiupmenz Are mechanical appliances properly installed and maintained ingood working condition? (|PK4[hOI1} PrI="Onm"a,2023 �1,u55 Page zmn STATUS CODE DESCRIPTION GENERAL NOTES Inspector: 8ARRYSTRATT0N Comments: Water heater installed without permits and inspections and still missing discharge tube. Location: Not Provided 111.6 Transfer of ownership. it shall be unlawful for the owner of any dwelling unit or structure who has received a compliance order or upon whom a notice of violation has been served to sell, transfer, mortgage, lease or otherwise dispose of such dwelling unicoroructu/ecoanotherund|rhepnovisionsofchecomp|ianceo/de/urnodceof violation have been complied with, or until such owner or the owner's authorized agent shall first furnish the grantee, transferee, mortgagee orlessee atrue copy ofany compliance order or notice of violation issued by the code official and shall furnish to the code official asigned and notarized starementfrom the grantee, transferee, mortgagee o/lessee, acknowledging the receipt ofsuch compliance order u/notice of violation and fully accepting the responsibility without condition for making the corrections or repairs required by such compliance order or notice of violation. BARRYSTKAJT0N'O5/ 6/2023@)1054 9'7'7:INSPECTIONS REQUIRED REINSPECTION DATE 06/13/2023 CONTACT SIGNATURE Joyce Wood Signed on: O5/10/Z0ZJ@10:54 INSPECTOR SIGNATURE BARRYSTRATT0N Signed on: 05/1§/2OZ3@1{:54 QUESTIONS ABOUT YOUR INSPECTION? BARRY5TRATTON bany.szenon@wanedoo'iaurg Prnted onewe,0z�/us Page amn