RENTAL INSPECTION - 200 INDEPENDENCE AVE - 5-16-23
FOR BILLING INQUIRY: (319)291-4323
[ Description
REINSPECTION FEE 3RD
Total Price j
$250.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
23001
06/21/2023
07/25/2023
2023-00020442
$250.00
Less Prepayment
Total Due -*
City of Waterloo
$0.00
$250.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
QUALITY CONCRETE MULTI UNIT COMPLEX, 200 INDEPENDENCE AVE, WATERLOO 1A S0703
DETAILS
Inspection Date: 05/16/2023 I Inspection Type: Rental Inspection I Inspection Number: 10062 I Shift: N/A I Station: N/A
Unit: N/A I Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee: $250.00
STATUS CODE DISC
4/4 -ins°
FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON - Comments: None
Location: Not Provided
FAIL 1031.7 - Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction, and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars, grilles, grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key, tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRY STRATTON - Comments: None
Location: Not Provided
FAIL 605.1 - Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment that is modified or -
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON - Comments: None
Location: Not Provided
PrI;ea ar O50 5r2023 10:55
Page 1 of 3
SnATUS CODE mcscxmr/mm
906.1 - Where required
Pot -table fire extinguishers shall be installed in all of the following locations: 1. in flew
and existing Group A,E, E, F,H.1,M,R'1'R-2.R-4and 5occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Iterns 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minirnurn rating of 1 -A: 1 O-B: C. 2. Within 30 feet (9144 mill)
ofcommercial cooking equipment. 3.|nareas where flammable orcombustible
liquids are stored, used ordispensed. 4.0neach floor ofstructures under
construction, except Group R-3 Occupancies, in accordance with Section 3315.1. 5.
Where required bythe sections indicated inTable 9OO1.0. Speda|'hazardarea»'
including but not limited to laboratories, computer rooms and generator rooms,
where required bythe fire code official.
Inspector: BARRYSTRATT0N Comments: Need Fire extinguisher
Location: Not Provided
FAIL RO-|ntehorSoucnuo* Has the interior ofthe Structure and equipment inside been maintained ingood
repair, structurally sound, and in a sanitary condition? (IPMC 305)
Inspector: B4RRYSTRATTON Comments: Peeling and abraded paint throughout,
Kitchen sink will not drain and is still leaking. Ceiling in bedroom falling and peeling
paint. Bathroom tub and shower valve needs replaced. Tub has peeling paint used in
tub. Peeling paint in bathroom, bedrooms, doors, handrail busted noupstairs broken
Location: Not Provided
FAIL R8�. Interior Structure- Were any unsafe conditions noted during the interior inspeoion?(|Pk0[30511)
Unsafe Conditions
Inspector: BARRYSTRATT0N Comments: Peeling and abraded paint throughout.
Kitchen sink will not drain and is still leaking. Ceiling in bedroom falling and peeling
paint. Bathroom tub and shower valve needs replaced. Tub has peeling paint used in
tub. Peeling paint inbathroom, bedrooms, doors, handrail busted tuupstairs broken
windows.
Location: Not Provided
FAIL R6E\ Residential Heating Are dwellings provided with heating facilities capable ofmaintaining aroom
temperature of68F?(|PMC002.2)
Inspector: B4RRYSTRATT0N Comments: Register covers
Location: Not Provided
FAIL mlC Mechanica|Eqiupmenz Are mechanical appliances properly installed and maintained ingood working
condition? (|PK4[hOI1}
PrI="Onm"a,2023 �1,u55
Page zmn
STATUS CODE DESCRIPTION
GENERAL NOTES
Inspector: 8ARRYSTRATT0N Comments: Water heater installed without permits and
inspections and still missing discharge tube.
Location: Not Provided
111.6 Transfer of ownership. it shall be unlawful for the owner of any dwelling unit or
structure who has received a compliance order or upon whom a notice of violation has
been served to sell, transfer, mortgage, lease or otherwise dispose of such dwelling
unicoroructu/ecoanotherund|rhepnovisionsofchecomp|ianceo/de/urnodceof
violation have been complied with, or until such owner or the owner's authorized
agent shall first furnish the grantee, transferee, mortgagee orlessee atrue copy ofany
compliance order or notice of violation issued by the code official and shall furnish to
the code official asigned and notarized starementfrom the grantee, transferee,
mortgagee o/lessee, acknowledging the receipt ofsuch compliance order u/notice of
violation and fully accepting the responsibility without condition for making the
corrections or repairs required by such compliance order or notice of violation.
BARRYSTKAJT0N'O5/ 6/2023@)1054 9'7'7:INSPECTIONS REQUIRED
REINSPECTION DATE
06/13/2023
CONTACT SIGNATURE
Joyce Wood
Signed on: O5/10/Z0ZJ@10:54
INSPECTOR SIGNATURE
BARRYSTRATT0N
Signed on: 05/1§/2OZ3@1{:54