RENTAL INSPECTION - 1738 FLOWER ST #3 - 6-13-23
FOR BILLING INQUIRY: (319)291-4323
[ Description
REINSPECTION FEE 3RD
Total Price
$250.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
10811
06/21/2023
07/25/2023
2023-00020454
$250.00
Less Prepayment
Total Due —�
City of Waterloo
$0.00
$250.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
DOMINIC TANGEN RENTAL 8-PLEX, 1738 FLOWER ST, WATERLOO IA S0701
DETAILS
Inspection Date: 06/13/2023 ( Inspection Type: Rental Inspection I Inspection Number: 10169 I Shift: N/A I Station: N/A 1
Unit: N/A I Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee: $250.00
STATUS CODE DESCRIPTION
.All4I4 -j;»3,
FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON - Comments: Door missing on # 3
Location: Not Provided
FAIL 1018.1 - General Aisles and aisle accessways serving as a portion of the exit access in the means of
egress system shall comply with the requirements of this section. Aisles or aisle
accessways shall be provided from all occupied portions of the exit access that
contain seats, tables, furnishings, displays and similar fixtures or equipment. The
minimum width or required capacity of aisles shall be unobstructed. Exception:
Encroachments complying with Section 1005.7.
Inspector: BARRY STRATTON - Comments: Egress/exit lights still not working
Location: Not Provided
FAIL 1031.2 - Reliability Required exit accesses, exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied. An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector: BARRY STRATTON - Comments: None
Location: Not Provided
P,in.ed on 06/13/2023 cc 09:57
Page 1 of 5
STATUS CODE DiSCRJPTION
FAIL 1031.7 - Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction, and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars, grilles, grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key, tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRY STRATTON - Comments: Broken windows
Location: Not Provided
FAIL 505.1 - Address identification New and existing buildings shall be provided with approved address identification.
The address identification shall be legible and placed in a position that is visible from
the street or road fronting the property. Address identification characters shall
contrast with their background. Address numbers shall be Arabic numbers or
alphabetical letters. Numbers shall not be spelled out. Each character shall be not
less than 4 inches (102 mm) high with a minimum stroke width of 1/2 (12.7 mm).
Where required by the fire code official, address identification shall be provided in
additional approved locations to facilitate emergency response. Where access is by
means of a private road and the building cannot be viewed from the public way, a
monument, pole or other sign or means shall be used to identify the structure.
Address identification shall be maintained.
Inspector: BARRY STRATTON - Comments: Need numbers on all apartments doors.
Location: Not Provided
FAIL 605.1 - Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
FAIL
901.6 - Inspection, testing and
maintenance
Inspector: BARRY STRATTON - Comments: Water damage electric panel in unit # 3 will
need replaced
Location: Not Provided
Fire detection, alarm, and extinguishing systems, mechanical smoke exhaust
systems, and smoke and heat vents shall be maintained in an operative condition at
all times, and shall be replaced or repaired where defective. Nonrequired fire
protection systems and equipment shall be inspected, tested and maintained or
removed.
Inspector: BARRY STRATTON - Comments: Alarm
Location: Not Provided
Printed an 06713/2023 (a. 03-57
Page 2 of 5
SMUS CODE DESCRIPTION
FAIL 9001 Where required Portable fire extinguishers shall be installed in all of the following locations: 1. in new
and existing Group A,E, E, F,H.1,K8'R'1.R'2'R-4and Soccupancies. Exception: in
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having aminimumrating of1'A:1U'8:C.Z.Within 3Ofeet (9144mnV
ofcommercial cooking equipment. 3.|nareas where flammable orcombustible
liquids are stored, used ordispensed. 4.Oneach floor ofstructures under
construction, except Group R'3occupancies, inaccordance with Section 3315.1.5.
Where required bythe sections indicated inTable 90h1.6. Speda|'hazardareas'
including but not limited to laboratories, computer rooms and generator rooms,
where required bythe fire code official.
FAIL 907.2.11 Single- and
multiple -station smoke
a|anno
Inspector: 8ARRYSTRATTON Comments: None
Location: Not Provided
Listed single- and multiple- station smoke alarms complying with UL217shall he
installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
Inspector: BARRYSTRATTON Comments: None
Location: Not Provided
FAIL K2 Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may
include boilers, heating equipment, elevator, moving stairways, electrical wiring, and
flammable liquid containers. (IPMC 108.1.2)
Inspector: BARRY STRATTON - Comments: All units 1-8
Location: Not Provided
FAIL R4 Exterior Property Areas |othe exterior property area maintained inaclean, safe, and sanitary condition? This
includes grading and drainage, sidewalks and driveways, weeds, and pest
Inspector: BARRY5TRATT0N Comments: Debris
Location: Not Provided
R5 Exterior Structure |» the exterior ofthe structure maintained ingood repair, structurally sound and
sanitary state? (IPMC 304)
m5 Interior Structure
Inspector: 8ARRY5TR/QTON Comments: Windows and electric service cabinet
Location: Not Provided
Has the interior ofthe structure and equipment inside been maintained ingood
repair, structurally sound, and inasanitary condition? (|Pu1[]O5)
,"".ed°"aa,a2023meMr
Page nmu
STATUS CODE
DESCRIPTION
Inspector: BARRY5TRATTON Comments: None
Location: Not Provided
FAIL Rh�.-|noyio/Struoure- Were any unsafe condhionsnoted during the interior inspecdon?(|PK4[30I1])
Unsafe Conditions
Inspector: 8ARRYSTRATT0N Comments: None
Location: Not Provided
FAIL R613. Residential Heating Are dwellings provided with heating facilities capable ofmaintaining aroom
temperature of08R(IPM[@02.2)
Inspector: BARRYSTRATT0N Comments: None
Location: Not Provided
FAIL R0l.'Mechanical Eqiupment Are mechanical appliances properly installed and maintained ingoodwmrking
condition? UPK4[0O3J>
Inspector: BARRYSTRATTON Comments: None
Location: Not Provided
GENERAL NOTES
BARRYSTRATT0N 06y13/2023@09:57 9'7'49'7'5: ZO33Rental Registration isneeded. Still not registered. Building has Dunits
REINSPECTION DATE
07/13/2023
CON TACT SIGNATURE
DuninicTangen
r�k
m�te*0�mms202u�� 09.57
Page *m5
INSPECT°
BARRY STRATTON
Signed on: 06/13/2023 @ 09:57
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319) 231-9147
Printed on 0O/1 3/2023 4 0907