Loading...
HomeMy WebLinkAbout1738 FLOWER STREET UNIT 3INVOICE DATE DUE DATE INVOICE # TOTAL DUE 06/21/2023 07/25/2023 2023-00020454 $250.00 Customer #: 10811 DOMINIC TANGEN 2501 SCENIC DR CEDAR FALLS, IA 50613 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 1738 FLOWER ST #3 - 6-13-23 FOR BILLING INQUIRY: (319)291-4323 [ Description REINSPECTION FEE 3RD Total Price $250.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 10811 06/21/2023 07/25/2023 2023-00020454 $250.00 Less Prepayment Total Due —� City of Waterloo $0.00 $250.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT DOMINIC TANGEN RENTAL 8-PLEX, 1738 FLOWER ST, WATERLOO IA S0701 DETAILS Inspection Date: 06/13/2023 ( Inspection Type: Rental Inspection I Inspection Number: 10169 I Shift: N/A I Station: N/A 1 Unit: N/A I Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee: $250.00 STATUS CODE DESCRIPTION .All4I4 -j;»3, FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON - Comments: Door missing on # 3 Location: Not Provided FAIL 1018.1 - General Aisles and aisle accessways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle accessways shall be provided from all occupied portions of the exit access that contain seats, tables, furnishings, displays and similar fixtures or equipment. The minimum width or required capacity of aisles shall be unobstructed. Exception: Encroachments complying with Section 1005.7. Inspector: BARRY STRATTON - Comments: Egress/exit lights still not working Location: Not Provided FAIL 1031.2 - Reliability Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector: BARRY STRATTON - Comments: None Location: Not Provided P,in.ed on 06/13/2023 cc 09:57 Page 1 of 5 STATUS CODE DiSCRJPTION FAIL 1031.7 - Emergency escape Required emergency escape and rescue openings shall be maintained in accordance and rescue openings with the code in effect at the time of construction, and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector: BARRY STRATTON - Comments: Broken windows Location: Not Provided FAIL 505.1 - Address identification New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) high with a minimum stroke width of 1/2 (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector: BARRY STRATTON - Comments: Need numbers on all apartments doors. Location: Not Provided FAIL 605.1 - Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. FAIL 901.6 - Inspection, testing and maintenance Inspector: BARRY STRATTON - Comments: Water damage electric panel in unit # 3 will need replaced Location: Not Provided Fire detection, alarm, and extinguishing systems, mechanical smoke exhaust systems, and smoke and heat vents shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. Inspector: BARRY STRATTON - Comments: Alarm Location: Not Provided Printed an 06713/2023 (a. 03-57 Page 2 of 5 SMUS CODE DESCRIPTION FAIL 9001 Where required Portable fire extinguishers shall be installed in all of the following locations: 1. in new and existing Group A,E, E, F,H.1,K8'R'1.R'2'R-4and Soccupancies. Exception: in Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having aminimumrating of1'A:1U'8:C.Z.Within 3Ofeet (9144mnV ofcommercial cooking equipment. 3.|nareas where flammable orcombustible liquids are stored, used ordispensed. 4.Oneach floor ofstructures under construction, except Group R'3occupancies, inaccordance with Section 3315.1.5. Where required bythe sections indicated inTable 90h1.6. Speda|'hazardareas' including but not limited to laboratories, computer rooms and generator rooms, where required bythe fire code official. FAIL 907.2.11 Single- and multiple -station smoke a|anno Inspector: 8ARRYSTRATTON Comments: None Location: Not Provided Listed single- and multiple- station smoke alarms complying with UL217shall he installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRYSTRATTON Comments: None Location: Not Provided FAIL K2 Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may include boilers, heating equipment, elevator, moving stairways, electrical wiring, and flammable liquid containers. (IPMC 108.1.2) Inspector: BARRY STRATTON - Comments: All units 1-8 Location: Not Provided FAIL R4 Exterior Property Areas |othe exterior property area maintained inaclean, safe, and sanitary condition? This includes grading and drainage, sidewalks and driveways, weeds, and pest Inspector: BARRY5TRATT0N Comments: Debris Location: Not Provided R5 Exterior Structure |» the exterior ofthe structure maintained ingood repair, structurally sound and sanitary state? (IPMC 304) m5 Interior Structure Inspector: 8ARRY5TR/QTON Comments: Windows and electric service cabinet Location: Not Provided Has the interior ofthe structure and equipment inside been maintained ingood repair, structurally sound, and inasanitary condition? (|Pu1[]O5) ,"".ed°"aa,a2023meMr Page nmu STATUS CODE DESCRIPTION Inspector: BARRY5TRATTON Comments: None Location: Not Provided FAIL Rh�.-|noyio/Struoure- Were any unsafe condhionsnoted during the interior inspecdon?(|PK4[30I1]) Unsafe Conditions Inspector: 8ARRYSTRATT0N Comments: None Location: Not Provided FAIL R613. Residential Heating Are dwellings provided with heating facilities capable ofmaintaining aroom temperature of08R(IPM[@02.2) Inspector: BARRYSTRATT0N Comments: None Location: Not Provided FAIL R0l.'Mechanical Eqiupment Are mechanical appliances properly installed and maintained ingoodwmrking condition? UPK4[0O3J> Inspector: BARRYSTRATTON Comments: None Location: Not Provided GENERAL NOTES BARRYSTRATT0N 06y13/2023@09:57 9'7'49'7'5: ZO33Rental Registration isneeded. Still not registered. Building has Dunits REINSPECTION DATE 07/13/2023 CON TACT SIGNATURE DuninicTangen r�k m�te*0�mms202u�� 09.57 Page *m5 INSPECT° BARRY STRATTON Signed on: 06/13/2023 @ 09:57 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 0O/1 3/2023 4 0907 Page 5 of 5