RENTAL INSPECTION - 1738 FLOWER #2 - 6-13-23
FOR BILLING INQUIRY: (319)291-4323
[ Description
Total Price
REINSPECTION FEE 3RD
$250.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
10811
06/21/2023
07/25/2023
2023-00020455
$250.00
Less Prepayment
Total Due
City of Waterloo
$0.00
$250.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
DOMINIC TANGEN RENTAL 8-PLE.X, 1738 FLOWER ST, WATERLOO IA 50701
DETAILS + a
ps\\
Inspection Date: 06/13/2023 I Inspection Type: Rental Inspection I Inspection Number: 10168 I Shift: N/A 1 Station: N/A
Unit: N/A I Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee: $250.00
STATUS CODE DESCRIPTION
FAIL 1013.3 - Illumination Exit signs shall be internally or externally illuminated. Exception: Tactile signs required
by Section 1013.4 need not be provided with illumination.
Inspector: BARRY STRATTON - Comments: Egress/exit lights
Location: Interior of building
FAIL 1025.5 - illumination Where photoluminescent exit path markings are installed, they shall be provided with
not less than 1 footcandle (11 lux) of illumination for not Tess than 60 minutes prior to
periods when the building is occupied and continuously during the building
occupancy.
Inspector: BARRY STRATTON - Comments: None
Location: Not Provided
FAIL 1031.2 - Reliability Required exit accesses, exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied. An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector: BARRY STRATTON - Comments: Outlets missing and wire being scrapped
from building
Location: All apartments.
FAIL 605.1 - Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON - Comments: Several electrical hazards exist throughout
building.
Location: Not Provided
Printed on 06/1342023 Cc 09:53
Page 1 of 5
urxroS CODE oasca/prION
FAIL 703.2 Openingprotecives Opening protectives shall be maintained in an operative condition in accordance with
NFPA 80. Where allowed by the fire code official, the application of field -applied labels
associated with the maintenance ofopening prm«ecLivesshall follow the
requirements of the approved third -party certification organization accredited for
listing the opening protective. Fire doors and smoke barrier doors shall not be
blocked or obstructed, or otherwise made inoperable. Fusible links shall be replaced
promptly whenever fused or damaged. Fire door assemblies shall not be modified.
901.6 Inspection, testing and
maintenance
Inspector: BARRY STRATTON - Comments: Alarm testing and maintenance has still not
been done.
Location: Not Provided
Fire detection, alarm, and extinguishing systems, mechanical srnoke exhaust
systems, and smoke and heat vents shall be maintained in an operative condition at
all times, and shall hereplaced o/repaired where defective. Nonrequiredfire
protection systems and equipment shall beinspected, tested and maintained o/
removed.
Inspector: BARRYSTRATT0N Comments: Alarm
Location: Not Provided
FAIL 901.6.1 Standards Fire protection systems shall be inspected, tested and maintained in accordance with
the referenced standards listed in Table .
| Location: Not Provided
FAIL 9061 Where required Portable fire extinguishers shall be installed in all of the following locations: 1. in new
and existing Group A,[\�F,H'|'K4'R'1.R'�R-4and Soccupancies. Exception: |o
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having aminimum rating of1f\:10-B:L2.Within J0feet (9144mm)
ofcommercial cooking equipment. l|nareas where flammable o/combustible
liquids are stored, used o/dispensed. 4.Oneach floor cfstructures under
construction, except Group R'3occupancies, inaccordance with Section 3315.1.5�
Where required bythe sections indicated inTable 9Oh.1.b.Special-hazard areas,
including but not limited to laboratories, computer rooms and generator rooms,
where required bythe fire code official.
Inspector: 8ARRYSTR/TT0N Comments: None
Location: Not Provided
PnnEeu=mms2023m09i53
Page zv,n
5 TA TLIS CODE DESCRIPTION
9072111 Single- and
multiple -station smoke
alarms
Listed single- and multiple- station smoke alarms complying with UL217shall he
installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
|nspeooc8ARRY STRATT0N Comments: Detectors missing throughout building and
all apartments.
Location: Interior ofBuilding
FAIL R2 Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may
include boilers, heating equipment, elevator, moving stairways, electrical wiring, and
flammable liquid containers. (IPIVIC 108.1.2)
Inspector: 8ARRYSTR/TT0N Comments: All units are uninhabitable. Building does
not rneet fire safety and rental requirements.
Location: Not Provided
FAIL R3 Unfit for Human is the structure found to be fit for human occupancy according to the code? (IPMC
Occupancy 1081.3;
Inspector: 8ARRYSTRATT0N Comments: Apartments 1'8
Location: Not Provided
FAIL R4 Exterior Property Areas is the exterior property area maintained in a clean, safe, and sanitary condition? This
includes grading and drainage, sidewalks and driveways, weeds, and pest
infestations. (|P/N[3O2)
Location: Not Provided
FAIL R5 Exterior Structure iothe exterior ofthe structure maintained ingood repair, structurally sound and
sanitary state? (IPMC 304)
Inspector: 8ARRY5TRATTUN'Comments: Windows, doors, electrical
Location: Not Provided
FAIL RO Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound, and inasanitary condition? ((PM[]05)
Inspector: BARRY5TRATT0N Comments: All units 1-8unfit nooccupy
Location: Not Provided
Page 3or5
`
STATUS CODE DESCRIPTION
FAIL �� |marior Structure- Were any unsafe conditions noted during the interior inspection?(|PM{3051J)
Unsafe Conditions
Location: Not Provided
FAIL R6.Ek Residential Heating Are dwellings provided with heating facilities capable ofmaintaining aroom
temperature of6QR(|PM{602.2)
Inspector: BARRY5TRATTON'Comments: None
Location: Not Provided
FAIL R6l. Mechaniox|Eqiupmeru Are mechanical appliances properly installed and maintained ingood working
condition? (|PM{O03J)
Inspector: BARRYSTR4TTON'Comments: None
Location: Not Provided
GENERAL NOTES
BARRYSTRAlTON 06/13/2023@ 09:52 9'749'7'5:2O2]Rental Registration isneeded. Still not registered
REINSPECTION DATE
07/13/2023