Loading...
HomeMy WebLinkAbout3330 E 4TH STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 06/12/2025 07/15/2025 2025-00000412 $100.00 Customer #: 24730 UNION AT NORTH CROSSING - CP 409 MASSACHUSETTS DETROIT, MI 48204 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 3330 E 4TH ST CLUB HOUSE - 5-15- 25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 20,000 OCCUPANCY FEE Total ]Price $90.00 $10.00 CUSTOMER# 24730 BILLING DATE 06/12/2025 DUE DATE 07/15/2025 INVOICE # 2025-00000412 CHARGES $100.00 Less Prepayment TotalDue —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report BLDG Union at North Crossing Club House 3330 E 4th St. - 3330 East 4th Street, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 05/15/2025 Lead Inspector Inspection Type Residential Common Areas Inspection Shift Station JEREMIAH VANDYKE NIA N/A Other Inspectors NIA 425 E. 3rd Street Inspection Number 16852 Unit NIA SUMMARY OF INSPECTION 0 25 Passed codes NEXT STEPS U3 Failed codes 4 NIA codes Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $80.00 Invoice Number NIA GENERAL NOTES Check Number N/A JEREMIAH VANDYKE - 05/16/2025 @ 19:07 Sprinkler, private hydrants, and fire alarms for all buildings due 10/18/2025. Reinspection Date 06/15/2025 Transaction Number N/A JEREMIAH VANDYKE - 05/16/2025 @ 19:07 PERMIT INFO: a€¢ Any construction requires proper permit and inspections. 'deft All electrical work and repair must be completed by a licensed electrical contractor with permits and inspections. JEREMIAH VANDYKE - 05/16/2025 @ 19:07 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone # 319-291- 2515. JEREMIAH VANDYKE - 05/16/2025 @ 19:07 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday a€" Friday, 8:00 a.m. de" 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 05/16/2025 @ 19:08 Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org a€" Work: 319-291-4460 - Cell: 319-883-1615 JEREMIAH VANDYKE - 05/16/2025 @ 19:08 Inspection Fee = $80.00 (To be mailed out by City via snail mail.) GENERATED ON 5/16/25, 2:09 PM 1 OF 3 SIGNATURES Contact signature Inspector signature No signature NA Danielle Lee - Property Manager CHECKLISTS Residential Common Areas Inspection Date: JEREMIAH VANDYKE Status Code Description 05116/2025 Fail 610.1.2 OThe lint trap, mechanical and heating components, and the Location: Clothes dryer maintenance. exhaust duct system of a clothes dryer shall be maintained in Comments: Discussed with Danielle the IFC code for clothes dryer accordance with the manufacturer's operating cleaning from back of maching to outside of the vents. Discussed instructions to prevent the accumulation of lint or debris that manufacturer recomendations of maintenance. This will be called out prevents the exhaust of air and products of combustion. during 2026 annual inspection for records of cleaning on all buildings. Fail 906.1 Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, 1, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10- pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I- 1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where Location: Fire extinguishers are past due. Comments: Need to contact Commerical fire extinguisher contractor to serivce and tag fire extinguishers in all buildings. GENERATED ON 5/16/25, 2:09 PM 2 OF 3 a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Additional Codes :`zat s Code Descriptivr� Fail 308.1.4 0 Charcoal burners and other open -flame cooking devices shall Location: Discussed grills about on balconies. not be operated on combustible balconies or within 10 feet Comments: Code information of use of open flame devices. Currently (3048 mm) of combustible construction. Exceptions: 1.One- not allowing them in balconies. and two-family dwellings. 2.Where buildings, balconies and decks are protected by an automatic sprinkler system. 3.LP- gas cooking devices having LP -gas container with a water capacity not greater than 21/ 2 pounds [nominal 1 pound (0.454 kg) LP -gas capacity]. GENERATED ON 5/16/25, 2:09 PM 3 OF 3