Loading...
HomeMy WebLinkAbout706 ANSBOROUGH AVE0 W4 0 rrriavt, nunnma rn • > y-.�"`"'" y 6 1 v t a INVOICE DATE DUE DATE INVOICE # TOTAL DUE 06/12/2025 07/15/2025 2025-00000399 $100.00 Customer #: 24725 FISHSTICK MILLWORK 706 ANSBOROUGH AVE WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 706 ANSBOROUGH AVE - 6-9-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 20,000 OCCUPANCY FEE Total Price $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24725 06/12/2025 07/15/2025 2025-00000399 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue ection Report— Fishstick Millwork - 706 Ansborough AVE, BLDG 706 Ansborough Ave, Waterloo IA 50701 INSP'€CTfON DETAILS Inspection Date Inspection Type 06/09/2025 Annual Inspection (1Yr) REINSPECTION ead Inspector Shut J 'VANDYKE Other inspectors N/A NIA 425 E. 3rd Street Inspection Number 642-R2 Station Unit NIA N/A SUMMARY OF INSPECTION 0 0 Passed codes NEXT STEPS 3 Failed codes Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org GENERAL NOTES JEREMIAH VANDYKE - 06/09/2025 @ 13:42 Reinspection Date 07/09/2025 Info<info@fishsticks.biz> a€c Jeremiah VanDyke a€( CAUTION: This email originated from outside the City of Waterloo email system. Do not click links or open unexpected attachments unless you recognize the sender and know the content is safe. I've received the quotes, just don't have the funds to pay for it at this time. From: Jeremiah VanDyke <Jeremiah.VanDyke@WATERLOO-IA.ORG> Sent: Monday, June 9, 2025 9:17 AM To: Info <info@fishsticks.biz>; Alexis Loew <alexisl@fishsticks.biz> Subject: Re inspect. Good Morning, The re inspect for 706 Ansborough has came up in our system. As we discussed in our last re inspect, we extended the re inspect time to get bids on repairing the fire alarm control panel. Has there been a bid accepted? And the plans on repairing or replacing the panel. Please advise as soon as possible. The re inspect for Thank you for your time. Lieutenant J.D. Van Dyke JEREMIAH VANDYKE - 06/09/2025 @ 13:43 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday a€" Friday, 8:00 a.m. a€" 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 06/09/2025 @ 13:43 Lt. Van Dyke - jeremi dyke@waterloo-ia.org a€" Work: 319-291-4460 - Cell: 319-883-1615 JEREMIAH VANDYKE - 06/09/2025 13:44 RE Inspection Fee = $100.00 (To be) mailed out by City via snail mail.) JEREMIAH VANDYKE - 12/04/2024 @ 15:29 10/05/2023 S - 5 Year Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed Compliant JEREMIAH VANDYKE - 12/04/2024 @ 15:29 09/19/2024 S - (Annual) Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed Deficient JEREMIAH VANDYKE - 12/04/2024 @ 15:29 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone # 319-291- 2515. GENERATED ON 6/9/25, 1:45 PM 1 OF 3 JEREMIAH VANDYKE - 12/04/2024 @ 15:29 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday At" Friday, 8:00 a.m. a€" 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection.'***"' Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 12/04/2024 @ 15:29 Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org a€" Work: 319-291-4460 - Cell: 319-883-1615 JEREMIAH VANDYKE - 12/04/2024 @ 15:29 Inspection Fee = $80.00 (To be mailed out by City via snail mail.) JEREMIAH VANDYKE - 12/04/2024 @ 15:29 Currently has quotes for exit signs and fire alarm panel install. No re inspect fee at this time. SIGNATURES Contact signature Inspector signature Tyler Rasmussen CHECKLISTS Reinspection Status Fail Fail Fail No signature NA Code Date: JEREMIAH VANDYKE 1203.2.15 Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Chapter 14 Fire alarm system tested at least annually by licensed contractor Description 06/09/2025 Location: Front showroom area, garage area, and new storage shed. Comments: 3 Egress lighting needed. Discussed installing combo Egress and Exit lights. Location: Exit signs in garage entry door, front lobby east door, and south door that is blocked. AND new storage shed above entry door. Comments: 4 Exit signs are needed or need repaired. Discussed installing combo Egress and Exit lights. Location: Fire Alarm panel. Comments: Fire alarm panel is off. Contact licensed fire alarm contractor to inspect fire alarm panel and to have fire alarm report uploaded to compliance engine by fire alarm contractor. GENERATED ON 6/9/25, 1:45 PM 2 OF 3 Statement of Fees FEE Invoice Date Inspection Fee N/A $100.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number N/A N/A GENERATED ON 6/9/25, 1:45 PM 3 OF 3