COMMERCIAL INSPECTION - 200 E ARLINGTON - 5-15-25
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
INSPECTION 20,000
OCCUPANCY FEE
$90.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
22864
06/12/2025
07/15/2025
2025-00000402
$100.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$100.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
Roosevelt Senior Housing - 200 E Arlington ST, BLDG 200 E Arlington St, Waterloo
IA 50703
INSPECTION DETAILS
Inspection Date
05/1512025
Lead Inspector
JEREMIAH VANDYKE
Inspection Type
Residential Common Areas Inspection
Other Inspectors
NIA
425 E. 3rd Street
Inspection Number
14428
Shift Station Unit
N/A NIA NIA
SUMMARY OF INSPECTION
0 22
Passed codes
NEXT STEPS
0 3 ® 6
Failed codes NIA codes
Please direct questions about your Inspection to:
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org
FEE
Invoice Date Inspection Fee
N/A 1 6100.00
Date Paid Amount Paid
Reinspection Date
06/15/2025
Invoice Number Cheek Number Transaction Number
N/A ,IQIA N/A
GENERAL NOTES
JEREMIAH VANDYKE - 05/15/2025 @ 15:58
Washer and clothes dryers removed from building.
JEREMIAH VANDYKE - 05/15/2025 @ 15:59
Fire extinguishers serviced by Superior October 2024.
JEREMIAH VANDYKE - 05/15/2025 @ 15:59
7/10/2024 S - (Annual) Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed Deficient
JEREMIAH VANDYKE - 05/15/2025 @ 15:59
7/10/2024 S - (Annual) Fire Alarm HAWKEYE ALARM Reviewed Compliant
JEREMIAH VANDYKE - 05/16/2025 @ 18:34
PERMIT INFO: A€6 Any construction requires proper permit and inspections. ACC All electrical work and repair must be completed by a licensed electrical
contractor with permits and inspections.
JEREMIAH VANDYKE - 0511612025 @ 18:34
Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are
Monday a€" Friday, 8:00 a.m. a€" 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be
performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. ***"*Re
inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.-
JEREMIAH VANDYKE - 05/16/2025 @ 18:34
GENERATED ON 5/16/25, 1:38 PM 1 OF 3
Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org a€" Work: 319-291-4460 - Cell: 319-883-1615
JEREMIAH VANDYKE - 05/16/2025 @ 18:35
Inspection Fee = $100.00 (To be mailed out by City via snail mail.)
SIGNATURES
Contact signature Inspector signature
No signature
NA
Coretta Crawley
Date: JEREMIAH VANDYKE
CHECKLISTS
Residential Common Areas Inspection
Status Code Description
05/16/2025
Fail 1032.4
0 Exit signs shall be installed and maintained in accordance Location: 1st floor main hallway leading into south stairwell.
with the building code that was in effect at the time of Comments: Exit/egress Tight tested and failed. Will need to replace or
construction and the applicable provisions in Section 1104. repair.
Decorations, furnishings, equipment or adjacent signage that
impairs the visibility of exit signs, creates confusion or
prevents identification of the exit shall not be allowed.
Fail
Fail
1104.5
Where means of egress illumination is provided, the power
supply for means of egress illumination shall normally be
provided by the premisesa€ " electrical supply. In the event
of power supply failure, illumination shall be automatically
provided from an emergency system for the following
occupancies where such occupancies require two or more
means of egress: 1.Group A having 50 or more occupants.
Exception: Assembly occupancies used exclusively as a
place of worship and having an occupant load of less than
300. 2.Group B buildings three or more stories in height,
buildings with 100 or more occupants above or below a level
of exit discharge serving the occupants or buildings with
1,000 or more total occupants. 3.Group E in interior exit
access and exit stairways and ramps, corridors, windowless
areas with student occupancy, shops and laboratories.
4.Group F having more than 100 occupants. Exception:
Buildings used only during daylight hours and that are
provided with windows for natural light in accordance with
the International Building Code . 5.Group I. 6.Group M.
Exception: Buildings less than 3,000 square feet (279 m2) in
gross sales area on one story only, excluding mezzanines.
7.Group R-1. Exception: Where each sleeping unit has direct
access to the outside of the building at grade. 8.Group R-2.
Exception: Where each dwelling unit or sleeping unit has
direct access to the outside of the building at grade.
704.1
Where required when the building was originally constructed,
materials and systems used to protect joints and voids in the
following locations shall be maintained. The materials and
Location: In hall way near room 204.
Comments: Egress light tested and failed. Will need to repair or
replace.
Location: 1st floor main hallway and north stair tower 1st and 2nd
floor.
GENERATED ON 5/16/25, 1:38 PM 2 OF 3
systems shall be securely attached to or bonded to the
adjacent construction, without openings visible through the
construction. 1.Joints in or between fire -resistance -rated
walls, floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall. 4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall. 5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall. 6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall. 7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly. Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed. Where the system design number is known, the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Comments: Holes in ceiling need repair. WILL NEED PERMIT and
inspection by City of Waterloo building department.