Loading...
HomeMy WebLinkAbout2332 FALLS AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 06/12/2025 07/15/2025 2025-00000401 $80.00 Customer #: 20423 METRO MART #4 2332 FALLS AV WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN:: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2332 FALLS AVE - 5-15-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 20423 06/12/2025 07/15/2025 2025-00000401 $80.00 Less Prepayment Total Due —÷ City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Re ,ort Metro 66 - 2332 Falls AVE, BLDG�2332 Falls Ave, Waterloo IA 50701 I PECTION DETAILS nspection Date 05/15/2025 d Inspector Brad :a •win Inspection Type Annual Inspection (1Yr) Other Inspectors JEFF SIEBEL 425 E. 3rd Street Inspection Number 13708 Shift Station Unit N/A N/A N/A SUMMARY OF INSPECTION 069 Passed codes NEXT STEPS 0 6 Failed codes Please direct questions about your Inspection to: Brad Baldwin brad.baldwin@waterloo-ia.org, 31929143 FEE Invoice Date N/A Inspection Fee $80.00 Date Paid Amount Paid Reinspection Date 06/12/2025 Invoice Number ♦ eck Number Transaction Number N/A N/A NIA GENERAL NOTES Brad Baldwin - 05/15/2025 @ 17:01 $80 annual inspection Brad Baldwin - 05/15/2025 @ 20:25 Moved combustibles away from cooking appliance in storage room during 5/15/25 inspection. Clearances shall be maintained. SIGNATURES Contact signature Inspector signature Lisa CHECKLISTS Means of Egress Status Fail O No signature Report completed post inspection Code 13B Date: Brad Baldwin 05/15/2025 1032.3 A means of egress shall be free from obstructions that would prevent its use, including the accumulation of snow and ice. Description Location: Rear (north) exit door. GENERATED ON 5/15/25, 3:37 PM 1 OF 3 Emergency Equipment Status Code Fail 1203.2.15 Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Additional Codes Comments: Remove obstructions to exit path or remove exit signage with wires properly contained in covered box. Per Building Official, Greg Ahlhelm, exit not required. Door locked during time of inspection, door is to remain unlocked during business hours if exit signage is present. Description Location: Front entrance exit sign Comments: Emergency lights on exit sign failed testing. Repair or replace. Stratus Code Description Fail 2305.5 l^_l Approved portable fire extinguishers complying with Section Location: Within 75 ft of fuel pumps 906 with a minimum rating of 2-A:20-B:C shall be provided and located such that an extinguisher is not more than 75 feet Comments: Provide properly serviced extinguisher within 75 feet of (22 860 mm) from pumps, dispensers or storage tank fill -pipe fuel pumps installed within 4 inches of floor and maximum 5 feet in height. openings. Fail 5303.5.3 Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellersa€" warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Electrical Safety Status Fail 0 Code 603.2 Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Portable Fire Extingusihers Status Fail Code 906.2 Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher Location: Storage room Comments: Secure compressed gas cylinders with chain to avoid tip over. Description Location: West exterior conduit elbow Comments: Install cover to conduit elbow properly Description Location: Behind counter GENERATED ON 5/15/25, 3:37 PM 2 OF 3 shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group I-3, portable fire extinguishers shall be permitted to be located at staff locations. Comments: Annual fire extinguisher service past due. Last serviced March 2024. GENERATED ON 5/15/25, 3:37 PM 3 OF 3