Loading...
HomeMy WebLinkAbout926 LINN STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/11/2025 04/15/2025 2025-00000293 $80.00 Customer #: 22283 SPEEDY MART 926 LINN STREET WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 926 LINN ST - 2-27-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price ] $70.00 $10.00 CUSTOMER # 22283 BILLING DATE 03/11/2025 DUE DATE 04/15/2025 INVOICE # 2025-00000293 CHARGES $80.00 Less Prepayment Total Due —+ City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT SPEEDY MART, 926 LINN ST, BLDG 926 LINN ST, WATERLOO ►A 50703 DETAILS Inspection Date: 02/27/2025 I Inspection Type: Annual Inspection (1Yr) I Inspection Number: 13318 I Shift: N/A I Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A I Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 28 I Violations: 7 I N/A Codes: 40 STATUS CODE DESCRIPTION 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch - pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Location: exit door to outside from kitchen Original Comment: repair exit door. Must unlatch with less than 15# force and swing to full open. Printed on 02/28/2025 @ 11:43 Page 1 of 5 STATUS CODE DESCRIPTION il. 102.3 - Change of use or occupancy. A change of occupancy shall not be made unless the use or occupancy is made to comply with the requirements of this code and the International Existing Building Code . Exception: Where approved by the fire code official, a change of occupancy shall be permitted without complying with the requirements of this code and the International Existing Building Code , provided that the new or proposed use or occupancy is Tess hazardous, based on life and fire risk, than the existing use or occupancy. Location: Kitchen Original Comment: Remove cot and bedding immediately. No sleeping or living in building allowed FAIL 102.4 - Application of building The design and construction of new structures shall comply with the code. International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. FAIL 1203.2.6 - Exit signs. Location: Electrical for new warmer at front of store Original Comment: Obtain electrical permit and inspections for new warmer installed without permit. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Back door from 924 Original Comment: repair exit/egress light Printed on 02/28/2025 01 11:43 Page 2 of 5 STATUS CODE DESCRIPTION FAIL 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: outlet cover on front of building Original Comment: replace missing water proof outlet cover. FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: employee only area street side of score Original Comment: remove obstructions to electric panel. Ladder and others. Printed on 02/28/2025 @ 11:43 Page 3 of 5 STATUS CODE DESCRIPTION FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: kitchen hood exhaust cleaning inspection report Original Comment: Provide current semi-annual kitchen hood exhaust system inspection report with all discrepancies corrected. Currently Out of Service/past due, and was not supposed to be used without permission from fire inspector. Contractor must upload online to the compliance engine. GENERAL NOTES JEFF SIEBEL - 02/28/2025 @ 11:39 annual inspection $80 JEFF SIEBEL - 02/28/2025 @ 11:40 Remove all bedding and cots from building immediately . No sleeping allowed at any time. REINSPECTION DATE 03/20/2025 CONTACT SIGNATURE DILAWAR KHAN 2023 Signed on: 02/28/2025 @ 11:41 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 02/28/2025 @ 11:41 'etx- ---"4 Printed on 02/28/2025 @ 11:43 Page 4 of 5 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/28/2025 @ 11:43 Page 5 of 5