Loading...
HomeMy WebLinkAbout230 E RIDGEWAY AVElumuuunnnr y_ i Customer #: 5687 JIM LIND STANDARD 230 E RIDGEWAY AV WATERLOO, IA 50702 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/11/2025 04/15/2025 2025-00000288 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 230 E RIDGEWAY AVE - 2-24-25 FOR BILLING INQUIRY: (319)291-4323 [ Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # 5687 BILLING DATE 03/11/2025 DUE DATE 04/15/2025 INVOICE # 2025-00000288 CHARGES $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT IIM LIND, 230 E RIDGEWAYAVE, BLDG 230 E RIDGEWAYAVE, WATERLOO IA 50702 DETAILS Inspection Date: 02/24/2025 I Inspection Type: Annual Inspection (1ber: 12525 Shift: N/A I Station: N/A Unit: N/A j Lead Inspector: JEFF SIEBEL ( Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 35 I Violations: 4 I N/A Codes: 36 STATUS CODE DESCRIPTION Fait 2305.5 - Fire extinguishers. FAIL 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Approved portable fire extinguishers complying with Section 906 with a minimum rating of 2-A:20-B:C shall be provided and located such that an extinguisher is not more than 75 feet (22 860 mm) from pumps, dispensers or storage tank fill -pipe openings. Location: For gas pumps Original Comment: Provide 2A 20BC fire extinguisher with 75 feet or install signage directing you to proper fire extinguisher. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Location: parts room by batteries. Original Comment: Secure compressed tanks with chain to stationary object. Printed on 02/24/2025 @ 15:27 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Lottery machine in store Original Comment: remove extension cord from lottery machine. You may use a circuit protected power tap. FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Not Provided Original Comment: Provide annual service for fire extiniushers. 6ENER4L NOTES JEFF SIEBEL - 02/24/2025 @ 15:24 annual inspection $80 JEFF SIEBEL - 02/24/2025 @ 15:24 dryer vent cleaned by Chimney Sweeps 1/10/25 Printed on 02/24/2025 @ 15:27 Page 2 of 3 REINSPECTION DATE 03/25/2025 CONTACT SIGNATURE Kerry Elliot Signed on: 02/24/2025 @ 15:25 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 02/24/2025 @ 15:25 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 -4rC Printed on 02/24/2025 @ 15:27 Page 3 of 3