HomeMy WebLinkAbout1831 INDEPENDENCE AVECustomer #: 3361
HALF PINT SALOON
1831 INDEPENDENCE AV
WATERLOO, IA 50707
INVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
03/11/2025
04/15/2025
2025-00000291
$80.00
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL INSPECTION - 1831 INDEPENDENCE AVE - 2-25-25
FOR BILLING INQUIRY: (319)291-4323
Description
INSPECTION 1 HH
OCCUPANCY FEE
Total Price J
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
3361
03/11/2025
04/15/2025
2025-00000291
$80.00
Less Prepayment
Total Due -->
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
HALF PINT SALOON, 1831 INDEPENDENCEAVE, BLDG 1831 INDEPENDENCEAVE, WATERLOO
L4 50703
DETAILS
Inspection Date: 02/25/2025 I Inspection Type: Annual Inspection
Unit: N/A 1 Lead Inspector: JEFF SIEBEL 1 Other Inspectors: N/A
VIOLATIONS AND COMPLIANCES
r: 12763 I Shift: N/A I Station: N/A
Showing only violations and images for this inspection. Please reach out to the lead inspector for more details.
Resolved Violations: 0 I Passed Codes: 35 I Violations: 3 I N/A Codes: 36
STATUS CODE DESCRIPTION
FAI L
5303.5.3 - Securing
compressed gas containers,
cylinders and tanks.
Compressed gas containers, cylinders and tanks shall be secured to prevent
falling caused by contact, vibration or seismic activity. Securing of compressed
gas containers, cylinders and tanks shall be by one of the following methods:
1.Securing containers, cylinders and tanks to a fixed object with one or more
restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile
device designed for the movement of compressed gas containers, cylinders or
tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container
filling or servicing facilities or in sellers' warehouses not open to the public.
Nesting shall be allowed provided that the nested containers, cylinders or tanks,
if dislodged, do not obstruct the required means of egress. 4.Securing of
compressed gas containers, cylinders and tanks to or within a rack, framework,
cabinet or similar assembly designed for such use. Exception: Compressed gas
containers, cylinders and tanks in the process of examination, filling, transport or
servicing.
Location: behind bar.
Original Comment: Secure tanks with chain.
Printed on 02/26/2025 @ 15:19
Page 1 of 3
STATUS CODE DESCRIPTION
'v l , 603.4 - Working space and
clearancesclearance.
A working space of not Working space around electrical equipment shall be
provided in accordance with Section 110.26 of NFPA 70 for electrical equipment
rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts. The minimum required working space shall be not less
than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches
(1981 mm) in height shall be providedin front of electrical service equipment.
Where the electrical service equipment is wider than 30 inches (762 mm), the
minimum working space shall be not Tess than the width of the equipment.
Storage of materials shall not be located within the designated working space.
Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2.
Access openings into attics or under -floor areas that provide a minimum clear
opening of 22 inches (559 mm) by 30 inches (762 mm).
Location: Electrical Room in Pool room
Original Comment: remove obstructions (TV) from in front of electrical panel.
FAIL 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring
and shall be listed and labeled in accordance with UL 817. Extension cords and
flexible cordsshall not be affixed to structures, extended through walls, ceilings
or floors, or under doors or floor coverings, nor shall such cords be subject to
environmental damage or physical impact. Extension cords shall be used only
with portable appliances. Extension cords marked for indoor use shall not be
used outdoors.
GENERAL NOTES
JEFF SIEBEL - 02/26/2025 @ 15:16
JEFF SIEBEL - 02/26/2025 @ 15:17
JEFF SIEBEL - 02/26/2025 @ 15:17
Location: Under Bar TV.
Original Comment: remove extension cords from under tv and to tv behind bar-2
orange cords. A power strip with a reset plugged directly into wall and properly
supported may be used for light duty usage such as tv's computers, led lights, etc
but not for motors or anything that produces heat or cooling.
annual inspection $80
Hood cleaning due 3/18/25
hood fire suppression due 3/30/25
Printed on 02/26/2025 @ 15:19
Page 2 of 3
REINSPECTION DATE
03/25/2025
CONTACT SIGNATURE
Mike Maker
Signed on: 02/26/2025 @ 15:18
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on: 02/26/2025 @ 15:17