HomeMy WebLinkAbout515 BROADWAY STINVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
03/28/2025
04/30/2025
2025-00000305
$80.00
Customer #: 20953
KWIK STOP #4
515 BROADWAY ST
WATERLOO, IA 50703
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL INSPECTION - 515 BROADWAY ST - 3-25-25
FOR BILLING INQUIRY: (319)291-4323
[ Description
INSPECTION 2,000
OCCUPANCY FEE
Total Price J
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
20953
03/28/2025
04/30/2025
2025-00000305
$80.00
Less Prepayment
Total Due —►
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
KWIK STOP 4, 515 BROADWAYST, BLDG 515 BROADWAYST, WATERLOO IA 50703
DETAILS
Inspection Date: 03/25/2025 ( Inspection Type: Annual Inspection (1 Yr) I Inspection Number: 13079 Shift: N/A I Station: N/A I
Unit: N/A I Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A Fee: $80.00
VIOLATIONS AND COMPLIANCES
Showing only violations and images for this inspection. Please reach out to the lead inspector for more details.
Resolved Violations: 0 I Passed Codes: 27 I Violations: 3 ( N/A Codes: 43
STATUS CODE DESCRIPTION
FAIL 305.1 - Clearance from Clearance between ignition sources, such as luminaires, heaters, flame -
ignition sources. producing devices and combustible materials, shall be maintained in an
approved manner.
Location: Back room by water heater
Original Comment: Remove all combustibles from within 36" of water heater.
Currently there are cigars piled around water heater.
FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be
clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment
rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts. The minimum required working space shall be not less
than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches
(1981 mm) in height shall be providedin front of electrical service equipment.
Where the electrical service equipment is wider than 30 inches (762 mm), the
minimum working space shall be not less than the width of the equipment.
Storage of materials shall not be located within the designated working space.
Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2.
Access openings into attics or under -floor areas that provide a minimum clear
opening of 22 inches (559 mm) by 30 inches (762 mm).
Location: Back room
Original Comment: Remove obstructions . Maintain a minimum of 36" clearance
to the electric panel at all times.
Printed on 03/26/2025 @ 10:03
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in
accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to
reach an extinguisher shall not apply to the spectator seating portions of Group
A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance
shall be allowed to be once every 3 years for dry -chemical or halogenated agent
portable fire extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the following conditions are
met: 2.1.Electronic monitoring shall confirm that extinguishers are properly
positioned, properly charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a trouble signal.
2.3.The extinguishers shall be installed inside of a building or cabinet in a
noncorrosive environment. 2.4.Electronic monitoring devices and supervisory
circuits shall be tested every 3 years when extinguisher maintenance is
performed. 2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at
the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers
shall be permitted to be located at staff locations.
GENERAL NOTES
JEFF SIEBEL - 03/26/2025 @ 10:00
REINSPECTION DATE
04/15/2025
CONTACT SIGNATURE
Mohammad Sarwat
Signed on: 03/26/2025 @ 10:00
Location: Not Provided
Original Comment: PJrovide annual service for all fire extingiushers
Annual Inspection fee $80
Printed on 03/26/2025 @ 10:03
Page 2 of 3
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on: 03/26/2025 @ 10:00
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 03/26/2025 @ 10:03
Page 3 of 3