Loading...
HomeMy WebLinkAbout2034 LA PORTE RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/28/2025 04/30/2025 2025-00000303 $100.00 Customer #: 12855 HAMPTON INN 2034 LA PORTE RD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2034 LA PORTE RD - 3-19-25 FOR BILLING INQUIRY: (319)291-4323 [ Description REINSPECTION 1 Total Price $100.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 12855 03/28/2025 04/30/2025 2025-00000303 $100.00 Less Prepayment Total Due —* City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT qb5 HAMPTON INN & SUITES, 2034 LA PORTE RD, BLDG 2034 LA PORTE RD, WATERLOO IA S0702 DETAILS Inspection Date: 03/19/2025 I Inspection Type: Annual Inspection (1Yr) I Inspection Number: 13671-R3 I Shift: N/A ( Station: N/A Unit: N/A Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 12 I Passed Codes: 0 I Violations: 20 I N/A Codes: 0 STATUS CODE DESCRIPTION FAIL 102.4 - Application of building The design and construction of new structures shall comply with the code. International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. FAI L Location: Entire buiding Original Comment: Obtain permits and inspections for all work concerning fire door repair, replacement smoke seals, all hardware replaced. Please see original attached email with codes concerning information requiered for fire door hardware. Please contact Building Official Greg Ahlhelm with questions. 319-291- 4319 Additional Comment: Obtain permits for all work concerning fire doors including smoke seals including bottom, new hardware installation and fire door replacement. 2015 IFC - Fire alarm testing Is the fire alarm system powered, operational and displaying normal operation and maintenance (no troubles, supervisory, or alarms)? Location: Room 128 Original Comment: repair smoke detector. Smoke detector and lights hanging by wires. Additional Comment: unabel to access room to verify 3/19/25 Printed on 03/2412025 @ 08:t0 Page 1 of 9 STATUS CODE DESCRIPTION FAIL 5.2.1 - Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor system inspection FAI L FAIL Location: Annual Fire Sprinkler Deficiency Original Comment: Provide current annual fire sprinkler report with all discrepancies corrected. Current report lists deficiencies . Contractor must upload corrections online to the compliance engine. Additional Comment: Still 2 deficiencies from 6/25/24 inspection. Contractor must post corrections online to the compliance engine. 5.2.1 - Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor system inspection Location: Annual Standpipe insepction deficiencies Original Comment: Provide current annual fire sprinkler stand pipe inspection report wth all discrepancies corrected. Current report lists 2 discrepancies. Contractor must upload corrections online to the compliance engine. Additional Comment: Stand pipe still showing 2 deficiencies. Contractor must upload corrections to the compliance engine. 5.2.1.1.5 - Missing Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall escutcheons be replaced if found missing during the inspection. Location: Room 300 Original Comment: replace missing eschutcheon above sink Additional Comment: Unable to access room. FAIL 506.2 - Key box maintenance. The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed. The key to such lock shall be secured in the key box. Location: KNOX BOX Original Comment: Update fire department access keys for every space after remodel Additional Comment: Please call for new keys placement. Printed on 03/24/2025 @ 08:10 Page 2 of 9 STATUS CODE DESCRIPTION FAIL 507.5.3 - Private fire service Private fire service mains and water tanks shall be periodically inspected, tested mains and water tanks. and maintained in accordance with NFPA 25 at the following intervals: 1.Private fire hydrants of all types: Inspection annually and after each operation; flow test and maintenance annually. 2.Fire service main piping: Inspection of exposed, annually; flow test every 5 years. 3.Fire service main piping strainers: Inspection and maintenance after each use. Records of inspections, testing and maintenance shall be maintained. Location: Private Fire Hydrant Deficiency Original Comment: Provide current semi-annual fire hydrant inspection and testing report with all discrepancies corrected. Current report lists deficiency. Contractor must upload corrections online to the compliance engine. Additional Comment: Repair fire hydrant deficiencies. Contractor must post correctons online to the compliance engine. FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Stairway Fire Door by room 330 Original Comment: Repair fire door. There is a gap at bottom of door. Must completely seal Additional Comment: Still gap at bottom, No hardware installed Printed on 03/24/2025 @ 08:10 Page 3 of 9 STATUS CODE DESCRIPTION FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5,Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Entire 4th Floor Fire Doors Original Comment: Repair or replace fire doors that are improperly installed. Doors must seal all sides including top and botom to prevent smoke/fire from inflitrating fire rated coridoor. Additional Comment: Need Inspections Printed on 03/24/2025 @ 08:10 Page 4 of 9 STATUS CODE DESCRIPTION i=AI L 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. S.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Entire second floor guest fire doors Original Comment: Install approved smoke seal in all fire door openings that has been removed including stair doors and utility areas. Check all other floors FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1 Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Guest Computer Room Original Comment: patch sheetrock ceiling with sheetrock. Mud and tape joints. Printed on 03/24/2025 @ 08:10 Page 5 of 9 STATUS CODE DESCRIPTION FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: IT equipment room in offices Original Comment: replace missing ceiling tiles. FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: obtain permit and inspections Printed on 03/24/2025 @ 08:10 Page 6 of 9 STATUS CODE DESCRIPTION FAIL 705.2.4 - Door operation. Swinging fire doors shall dose from the full -open position and latch automatically. FAIL FAIL FAI L Location: West 3rd floor storage room fire door Original Comment: repair door. Fire Door must completely self -close and latch 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Location: 3rd Floor West stair fire door Original Comment: Repair door. Fire door must completly self -close and latch. 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Location: 2nd Floor laundry inside door Original Comment: Repair fire door. Fire door must completely self -close and latch. Upper part of door does not properly seal. 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Location: Room 202 Original Comment: repair door . Fire door must completely self -close and latch. Printed on 03/24/2025 @ 08:10 Page 7 of 9 STATUS CODE DESCRIPTION FAIL 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. FAIL FAIL Location: 2nd Floor East Electrical Room Original Comment: Repair door .Inside fire door must completly self -close and latch. Repair smoke seal Additional Comment: Still gap at the bottom. 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Location: Room 319 Fire Door and smoke detector Original Comment: Fire door must completely self -close and latch. Smoke detector not working Chapter 14 - Inspection, Fire alarm system tested at least annually by licensed contractor testing, and maintenance GENERAL NOTES JEFF SIEBEL - 02/14/2025 @ 15:29 JEFF SIEBEL - 02/14/2025 @ 15:29 JEFF SIEBEL - 02/14/2025 @ 15:29 Location: Annual Fire Alarm Inspection Original Comment: Provide current semi-annual fire alarm inspection report with all discrepancies corrected. Currently 106 days past due. Contractor must upload online to the compliance engine. Provide corrections to avoid re -inspection fees Annual inspection $235 Provide corrections to avoid re -inspection fees. Printed on 03/24/2025 @ 08:10 Page 8 of 9 GENERAL NOTES JEFF SIEBEL - 03/24/2025 @ 08:02 Re -inspection fee $100 JEFF SIEBEL - 03/24/2025 @ 08:06 Corrections not made on fire sprinkler, standpipe, or fire alarm and no date for completion of fire door certifications. REINSPECTION DATE 04/17/2025 CONTACT SIGNATURE Mitch Goodrich - Maintenance Signed on: 03/24/2025 @ 08:06 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 03/24/2025 @ 08:06 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 1-) M 1- Printed on 03/24/2025 @ 08:10 Page 9 of 9