Loading...
HomeMy WebLinkAbout2020 BOPP STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 04/04/2025 05/08/2025 2025-00000317 $100.00 Customer #: 24677 RED LIGHT MARKET 2020 BOPP ST WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2020 BOPP ST - 3-21-25 FOR BILLING INQUIRY: (319)291-4323 Description REINSPECTION 1 Total Price $100.00 CUSTOMER # 24677 BILLING DATE 04/04/2025 DUE DATE 05/08/2025 INVOICE # 2025-00000317 CHARGES $100.00 Less Prepayment Total Due —► City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE aLi(0---T) INSPECTION REPORT RED LIGHT MARKET, 2020 BOPP ST, BLDG 2020 BOPP ST - STE 2020 BOPP ST, WATERLOO S0702 IOU `` j� r ^O DETAILS Inspection Da Unit: N/A I L e: 03/21 /2025 I d Inspector: JE Inspection Type: Annual Inspection (1Yr) I Inspection Number: 16184-R1 I Shift: N/A Station: N/A F SIEBEL ( Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 2 I Passed Codes: 0 I Violations: 9 I N/A Codes: 0 STATUS CODE DESCRIPTION FAIL 1010.2.9 - Panic and fire exit Swinging doors serving a Group H occupancy and swinging doors serving rooms hardware. or spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock other than panic hardware or fire exit hardware. Exceptions: 1.A main exit of a Group A occupancy shall be permitted to have locking devices in accordance with Section 1010.2.4, Item 2 3. 2.Doors provided with panic hardware or fire exit hardware and serving a Group A or E occupancy shall be permitted to be electrically locked in accordance with Section 1010.2.12 or 1010.2.11. 3. Exit access doors serving occupied exterior areas shall be permitted to be locked in accordance with Section 1010.2.4, Item 8. 4.Courtrooms shall be permitted to be locked in accordance with Section 1010.2.13, Item 3. Electrical rooms with equipment rated 1,200 amperes or more and over 6 feet (1829 mm) wide, and that contain overcurrent devices, switching devices or control devices with exit or exit access doors, shall be equipped with panic hardware or fire exit hardware. The doors shall swing in the direction of egress travel. Location: Back door in back storeroom Original Comment: Permanently remove barricade and brackets from exit door or have reviewed by building official Greg Ahlhelm to deterimine if required. Printed on 03/24/2025 @ 09:47 Page 1 of 6 STATUS CODE DESCRIPTION FAIL 102.3 - Change of use or A change of occupancy shall not be made unless the use or occupancy is made to occupancy. comply with the requirements of this code and the International Existing Building Code . Exception: Where approved by the fire code official, a change of occupancy shall be permitted without complying with the requirements of this code and the International Existing Building Code , provided that the new or proposed use or occupancy is less hazardous, based on life and fire risk, than the existing use or occupancy. FAI L 102.4 - Application of building code. Location: Furnace room Original Comment: NO SLEEPING IN BUILDING. REMOVE ALL BEDDING AND MATRESSES IMMEDIATLY. Additional Comment: Bedding was removed on inspection 4/20/25 The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Location: Water heater Original Comment: Obtain water heater permits and inspections for water heater. FAIL 102.4 - Application of building The design and construction of new structures shall comply with the code. International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Location: Three compartment sink Original Comment: Obtain plumbing permit and inspections for sink installation that was installed without. Printed on 03/24/2025 @ 09:47 Page 2 of 6 STATUS CODE DESCRIPTION FAIL 102.4 - Application of building The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. code. FAIL 1203.2.6 - Exit signs. Location: New Wall Original Comment: Obtain building permit and inspections for new wall constructed without. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: middle of back room Original Comment: repair egress/exit light Printed on 03/24/2025 @ 09,47 Page 3 of 6 STATUS CODE DESCRIPTION FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: rear exit door in back room Original Comment: repair egress exit light or request building official Greg Ahlhelm review to see if required. FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: West Exit Door Original Comment: repair exit/egress lilght Printed on 03/24/2025 @ 09:47 Page 4 of 6 STATUS CODE DESCRIPTION FAIL 906.1 - Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10- B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10-pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1-1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. EENERAL NOTES JEFF SIEBEL - 02/21/2025 @ 10:47 JEFF SIEBEL - 03/24/2025 @ 09:45 REINSPECTION DATE 04/10/2025 Location: Entire Store Original Comment: Mount currently serviced fire extinguisher 4" to 5' above the floor in an accesible location within 75' of any location in store and back room areas. Annual Inspection $80 re -inspection $100 Printed on 03/24/2025 @ 09:47 Page 5 of 6 CONTACTSIGNATURE Kumba-store owner Signed on: 03/24/2025 @ 09:45 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 03/24/2025 @ 09:45 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 03/24/2025 @ 09:47 Page 6 of 6