HomeMy WebLinkAbout777 ISLE OF CAPRIINVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
04/04/2025
05/08/2025
2025-00000315
$610.00
Customer #: 13049
ISLE OF CAPRI
ACCOUNTS PAYABLE
777 ISLE OF CAPRI BLVD
WATERLOO, IA 50701
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL INSPECTION - 777 ISLE OF CAPRI - 3-27-25
FOR BILLING INQUIRY: (319)291-4323
Description
INSPECTION 100,000
OCCUPANCY FEE
Total', Price
$600.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
13049
04/04/2025
05/08/2025
2025-00000315
$610.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$610.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
)OY9
INSPECTION REPORT
ISLE OF CAPRI, 777 ISLE OF CAPRI BLVD, BLDG 777 ISLE OF CAPRI BLVD, WATERLOO IA 50702
DETAILS
Inspection Date: 03/27/2025 1 Inspection Type: Annual Inspection (1Yr) 1 Inspection Number: 13845 1 Shift: N/A 1 Station: N/A
Unit: N/A 1 Lead Inspector: JEFF SIEBEL 1 Other Inspectors: BROCK WELIVER, JEREMIAH VANDYKE ( Fee: $610.00
VIOLATIONS AND COMPLIANCES
Showing only violations and images for this inspection. Please reach out to the lead inspector for more details.
Resolved Violations: 0 1 Passed Codes: 59 1 Violations: 4 I N/A Codes: 11
STATUS CODE DESCRIPTION
FAIL
5.2.1.1.5 - Missing
escutcheons
Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall
be replaced if found missing during the inspection.
Location: rooms 616 and621
Original Comment: replace missing escutcheons.
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1.joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: room 916, maids room by 808, 708, 608, 308
Original Comment: Replace all missing smoke seals including above listed rooms.
Printed on 03/31/2025 @ 09:11
Page 1 of 3
STATUS CODE DESCRIPTION
906.2 - General requirements.
Portable fire extinguishers shall be selected, installed and maintained in
accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to
reach an extinguisher shall not apply to the spectator seating portions of Group
A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance
shall be allowed to be once every 3 years for dry -chemical or halogenated agent
portable fire extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the following conditions are
met: 2.1.Electronic monitoring shall confirm that extinguishers are properly
positioned, properly charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a trouble signal.
2.3.The extinguishers shall be installed inside of a building or cabinet in a
noncorrosive environment. 2.4.Electronic monitoring devices and supervisory
circuits shall be tested every 3 years when extinguisher maintenance is
performed. 2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at
the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers
shall be permitted to be located at staff locations.
Location: penthouse
Original Comment: provide annual service for fire extingiusher
7A1L 907.8.1 - Maintenance Where required for compliance with the provisions of this code, devices,
required. equipment, systems, conditions, arrangements, levels of protection or other
features shall thereafter be continuously maintained in accordance with
applicable NFPA requirements or as directed by the fire code official.
Location: Multiple floors and rooms. including 822 with overspray
Original Comment: Canvas all guest rooms and replace all missing smoke
detector trim. Smoke detectors and appurtances must all be maintained as
tested by listing agency and installed per manufacturers recommendations.
Provide docutmentation of replacement parts and installations by room
numbers.
GENERAL NOTES
JEFF SIEBEL - 03/27/2025 @ 14:53 Annual inspection $610
JEFF SIEBEL - 03/31/2025 @ 08:51 Fire inspection Reports
Printed on 03/31/2025 @ 09:11
Page 2 of 3
GENERAL NOTES
JEFF SIEBEL- 03/31/2025 @ 08:53
JEFF SIEBEL - 03/31/2025 @ 08:54
JEFF SIEBEL - 03/31/2025 @ 08:54
REINSPECTION DATE
04/10/2025
CONTACT SIGNATURE
Danny Lane
Signed on: 03/31/2025 @ 09:09
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on: 03/31/2025 @ 09:09
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
generator reports
generator
generator reports
Printed on 03/31/2025 @ 09:11
Page 3 of 3