Loading...
HomeMy WebLinkAbout777 ISLE OF CAPRIINVOICE DATE DUE DATE INVOICE # TOTAL DUE 04/04/2025 05/08/2025 2025-00000315 $610.00 Customer #: 13049 ISLE OF CAPRI ACCOUNTS PAYABLE 777 ISLE OF CAPRI BLVD WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 777 ISLE OF CAPRI - 3-27-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 100,000 OCCUPANCY FEE Total', Price $600.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 13049 04/04/2025 05/08/2025 2025-00000315 $610.00 Less Prepayment Total Due —> City of Waterloo $0.00 $610.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE )OY9 INSPECTION REPORT ISLE OF CAPRI, 777 ISLE OF CAPRI BLVD, BLDG 777 ISLE OF CAPRI BLVD, WATERLOO IA 50702 DETAILS Inspection Date: 03/27/2025 1 Inspection Type: Annual Inspection (1Yr) 1 Inspection Number: 13845 1 Shift: N/A 1 Station: N/A Unit: N/A 1 Lead Inspector: JEFF SIEBEL 1 Other Inspectors: BROCK WELIVER, JEREMIAH VANDYKE ( Fee: $610.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 1 Passed Codes: 59 1 Violations: 4 I N/A Codes: 11 STATUS CODE DESCRIPTION FAIL 5.2.1.1.5 - Missing escutcheons Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall be replaced if found missing during the inspection. Location: rooms 616 and621 Original Comment: replace missing escutcheons. FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: room 916, maids room by 808, 708, 608, 308 Original Comment: Replace all missing smoke seals including above listed rooms. Printed on 03/31/2025 @ 09:11 Page 1 of 3 STATUS CODE DESCRIPTION 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: penthouse Original Comment: provide annual service for fire extingiusher 7A1L 907.8.1 - Maintenance Where required for compliance with the provisions of this code, devices, required. equipment, systems, conditions, arrangements, levels of protection or other features shall thereafter be continuously maintained in accordance with applicable NFPA requirements or as directed by the fire code official. Location: Multiple floors and rooms. including 822 with overspray Original Comment: Canvas all guest rooms and replace all missing smoke detector trim. Smoke detectors and appurtances must all be maintained as tested by listing agency and installed per manufacturers recommendations. Provide docutmentation of replacement parts and installations by room numbers. GENERAL NOTES JEFF SIEBEL - 03/27/2025 @ 14:53 Annual inspection $610 JEFF SIEBEL - 03/31/2025 @ 08:51 Fire inspection Reports Printed on 03/31/2025 @ 09:11 Page 2 of 3 GENERAL NOTES JEFF SIEBEL- 03/31/2025 @ 08:53 JEFF SIEBEL - 03/31/2025 @ 08:54 JEFF SIEBEL - 03/31/2025 @ 08:54 REINSPECTION DATE 04/10/2025 CONTACT SIGNATURE Danny Lane Signed on: 03/31/2025 @ 09:09 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 03/31/2025 @ 09:09 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 generator reports generator generator reports Printed on 03/31/2025 @ 09:11 Page 3 of 3