HomeMy WebLinkAbout1309 LAFAYETTE STINVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
04/16/2025
05/20/2025
2025-00000327
$80.00
Customer #: 23198
PRIME MART 7
1309 LAFAYETTE ST
WATERLOO, IA 50703
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL INSPECTION - 1309 LAFAYETTE ST - 3-14-25
FOR BILLING INQUIRY: (319)291-4323
Description,
INSPECTION 2,000
OCCUPANCY FEE
Total Price
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
23198
04/16/2025
05/20/2025
2025-00000327
$80.00
Less Prepayment
Total Due —►
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
PRIME MART 7,1309 LAFAYETTE ST, BLDG 1309 LAFAYETTE ST, WATERLOO IA 50703
DETAILS
Inspection Date: 03/14/2025 I Inspection Type: Annual Inspection (1 Yr) I Inspection Number: 13178 I Shift: N/A I Station: N/A E
Unit: N/A I Lead Inspector: JEFF SIEBEL ( Other Inspectors: N/A f Fee: $80.00
VIOLATIONS AND COMPLIANCES
Showing only violations and images for this inspection. Please reach out to the lead inspector for more details.
Resolved Violations: 0 I Passed Codes: 27 I Violations: 3 I N/A Codes: 43
STATUS CODE DESCRIPTION
FAIL
603.5 - Relocatable power
taps and current
taps.Multiplug adapters.
Multiplug adapters, such as cube adapters, unfused plug strips or any other
device not complying with NFPA 70 shall be prohibited. The construction and use
of current taps and relocatable taps shall be in accordance with NFPA 70 and this
code.
Location: Freezer by front counter
Original Comment: remove power strip. freezer must plug directly into
permanent outlet.
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1 joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: Back room
Original Comment: replace missing ceiling in backroom.
Printed on 03/17/2025 @ 08:13
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in
accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to
reach an extinguisher shall not apply to the spectator seating portions of Group
A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance
shall be allowed to be once every 3 years for dry -chemical or halogenated agent
portable fire extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the following conditions are
met: 2.1.Electronic monitoring shall confirm that extinguishers are properly
positioned, properly charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a trouble signal.
2.3.The extinguishers shall be installed inside of a building or cabinet in a
noncorrosive environment. 2.4.Electronic monitoring devices and supervisory
circuits shall be tested every 3 years when extinguisher maintenance is
performed. 2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at
the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers
shall be permitted to be located at staff locations.
Location: Not Provided
Original Comment: Provide annual service for all fire extingjuishers.
GENERAL NOTES
JEFF SIEBEL - 03/17/2025 @ 08:11 annual inspection $80
REINSPECTION DATE
04/03/2025
CONTACT SIGNATURE
Usman Chatha
Signed on: 03/17/2025 @ 08:07
-444:7
Printed on 03/17/2025 @ 08:13
Page 2 of 3
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on: 03/17/2025 @ 08:07
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 03/17/2025 @ 0B:13
Page 3 of 3