Loading...
HomeMy WebLinkAbout1309 LAFAYETTE STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 04/16/2025 05/20/2025 2025-00000327 $80.00 Customer #: 23198 PRIME MART 7 1309 LAFAYETTE ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1309 LAFAYETTE ST - 3-14-25 FOR BILLING INQUIRY: (319)291-4323 Description, INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23198 04/16/2025 05/20/2025 2025-00000327 $80.00 Less Prepayment Total Due —► City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT PRIME MART 7,1309 LAFAYETTE ST, BLDG 1309 LAFAYETTE ST, WATERLOO IA 50703 DETAILS Inspection Date: 03/14/2025 I Inspection Type: Annual Inspection (1 Yr) I Inspection Number: 13178 I Shift: N/A I Station: N/A E Unit: N/A I Lead Inspector: JEFF SIEBEL ( Other Inspectors: N/A f Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 27 I Violations: 3 I N/A Codes: 43 STATUS CODE DESCRIPTION FAIL 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: Freezer by front counter Original Comment: remove power strip. freezer must plug directly into permanent outlet. FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1 joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Back room Original Comment: replace missing ceiling in backroom. Printed on 03/17/2025 @ 08:13 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Not Provided Original Comment: Provide annual service for all fire extingjuishers. GENERAL NOTES JEFF SIEBEL - 03/17/2025 @ 08:11 annual inspection $80 REINSPECTION DATE 04/03/2025 CONTACT SIGNATURE Usman Chatha Signed on: 03/17/2025 @ 08:07 -444:7 Printed on 03/17/2025 @ 08:13 Page 2 of 3 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 03/17/2025 @ 08:07 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 03/17/2025 @ 0B:13 Page 3 of 3