Loading...
HomeMy WebLinkAbout821 BROADWAY STII 1i1U11IUUUi. y INVOICE DATE DUE DATE INVOICE # TOTAL DUE 04/16/2025 05/20/2025 2025-00000320 $80.00 Customer #: 13529 BROADWAY LIQUOR 821 BROADWAY ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 821 BROADWAY ST - 4-3-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 13529 04/16/2025 05/20/2025 2025-00000320 $80.00 Less Prepayment Total Due City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT BROADWAYLIQUOR, 821 BROADWAYST, BLDG 821 BROADWAYST, WATERLOO ►A S0703 13 DETAILS Inspection Date: 04/03/2025 j Inspection Type: Annual Inspection (1Yr) 1 Inspection Number: 14147 I Shift: N/A I Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL ( Other Inspectors: N/A 1 Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 30 I Violations: 4 I N/A Codes: 40 STATUS CODE DESCRIPTION FAIL FAIL 6063.3.2 - Grease If during the inspection it is found that hoods, grease -removal devices, fans, accumulation. ducts or other appurtenances have an accumulation of grease, such components shall be cleaned in accordance with ANSI/IKECA C10. 606.3.3.3 - Records. Location: Grease filters Original Comment: Clean excess grease from filters . Excess grease on filters will drip and continue feeding fire after suppression system has expired. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: Kitchen hood exhaust system cleaning Original Comment: Provide current semi-annual kitchen hood cleaning inspection report with all deficiencies corrected. Currently 189 days past due. Contractor must upload online to the compliance engine. Printed on 04/04/2025 @ 11:53 Page 1 of 3 STATUS CODE DESCRIPTION FAl L 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. 906.2 - General requirements. GENERAL NOTES Location: Kitchen hood fire suppression inspection Original Comment: Provide current semi-annual kitchen hood fire suppression inspection report with all deficiencies corrected. Currently 139 days past due. Contractor must upload online to the compliance engine. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: all fire extinguishers Original Comment: provide annual service for fire extinguishers. JEFF SIEBEL - 04/04/2025 @ 11:49 annual inspection $80 Printed on 04/04/2025 @ 11:53 Page 2 of 3 REINSPECTION DATE 04/28/2025 CONTACT SIGNATURE Muhammad Shahaz Signed on: 04/04/2025 @ 11:50 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 04/04/2025 @ 11:50 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 04/04✓2025 @ 11:53 Page 3 of 3