Loading...
HomeMy WebLinkAbout850 PARK RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 04/16/2025 05/20/2025 2025-00000330 $100.00 Customer #: 11090 RIVER FRONT STADIUM 850 PARK RD WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 850 PARK RD - 3-31-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 20,000 OCCUPANCY FEE Total Price $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 11090 04/16/2025 05/20/2025 2025-00000330 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT WATERLOO RWYERFRONT STADIUM, 850 PARK RD, BLD6 830 PARK RD, WATERLOO /A S0703 DETAILS Inspection Date: 03/31/2025 I Inspection Type: Annual Inspection (1Yr) ( Inspection Number: 13672 Shift: N/A I Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A VIOLATIONS AND COMPLIANCES \,eo Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 38 I Violations: 8 I N/A Codes: 33 STATUS CODE FAIL FAIL FAIL DESCRIPTION 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in illumination. accordance with Sections 1008.3 and 1104.5.1. Location: Visitors clubhouse across from lavatories. Original Comment: repair egress light. 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in illumination. accordance with Sections 1008.3 and 1104.5.1. Location: by visiting field entrance Original Comment: repair egress light 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in illumination. accordance with Sections 1008.3 and 1104.5.1. Location: By Umpire Lounge Original Comment: repair egress light. Printed on 03/31/2025 @ 15:11 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in illumination. accordance with Sections 1008.3 and 1104.5.1. Location: Men's restroom by green sign Original Comment: repair egress light FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Dish room in concessions Original Comment: repair exit/egress Tight FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Above k-guard extinguisher in kitchen Original Comment: repair exit light FAIL 610.1.2 - Maintenance. The lint trap, mechanical and heating components, and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Location: Laundry room Original Comment: Provide current cleaning of the dryer vents to the outside of the buildindg. Printed on 03/31/2025 @ 15:11 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: entire complex Original Comment: provide annual service for fire extingiushers GENERAL NOTES JEFF SIEBEL - 03/31/2025 @ 14:54 Annual inspection $100 REINSPECTION DATE 04/22/2025 CONTACT SIGNATURE Jordan Yessak 2024 Signed on: 03/31/2025 @ 15:06 Printed on 03/31/2025 @ 15:11 Page 3 of 4 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 03/31/2025 @ 15:06 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 03/31/2025 @ 15:11 Page 4 of 4