Loading...
HomeMy WebLinkAbout1050 SOUTHTOWN DRCustomer #: 4746 HOME DEPOT 3207 GREY HAWK COURT SUITE 200 CARLSBAD, CA 92010 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 04/16/2025 05/20/2025 2025-00000333 $610.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1050 SOUTHTOWN DR - 4-4-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 100,000 OCCUPANCY FEE Total Price $600.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 4746 04/16/2025 05/20/2025 2025-00000333 $610.00 Less Prepayment Total Due —> City of Waterloo $0.00 $610.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT HOME DEPOT, 1050 SOUTHTOWN DR, BLDG 1050 SOUTHTOWN DR, WATERLOO /A 50702 01'1 (12 DETAILS Inspection Date: 04/04/2025 ( Inspection Type: Annual Inspection (1Yr) I Inspection Number: 7138 j Shift: N/A ( Station: N/A Unit: N/A j Lead Inspector: JEFF SIEBEL ! Other Inspectors: N/A I Fee: $610.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 37 I Violations: 6 I N/A Codes: 31 STATUS CODE DESCRIPTION FAIL 1203.4.3 - Records. Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. Location: All exit and egress lights including : Exit light maint entrance , Exit by 19 and 20, Exit, and egress light East door in bat cave. Original Comment: Provide documentation of testing and repair of all emergency exit and egress lights in building including above with signature and date. FAIL 1203.4.3 - Records. Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. Location: Emergency generator Original Comment: Provide current emergeny generator testing inspection and load bank testing or monthly maintenance testing with all discrepancies corrected. Load bank only required every 2 years if monthly maintenance log maintained. Printed on 04/07/2025 @ 09:56 Page 1 of 4 STATUS CODE DESCRIPTION AIL 505.1 - Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) high with a minimum stroke width of 1/2 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Location: Street side of building Original Comment: Provide adress on street side of building in 6" numbers of contrasting color to the background. FAIL 509.1 - Identification. Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems, sprinkler risers and valves, or other fire detection, suppression or control elements fire protection systems shall be identified for the use of the fire department. Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. 509.2 - Equipment access. Location: room containing fire alarm panel Original Comment: Install permanent signage on doors leading to Fire alarm control panel stating "FACP or Fire Alarm Control Panel Room". Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Location: Fire alarm control panel Original Comment: Remove obstructions to fire alarm control panel and appertencances . Maintain a minimum of 36" clearance. Floor is already marked, signage may help. Printed on 04/07/2025 @ 09:56 Page 2 of 4 STATUS CODE DESCRIPTION 704.1 - Maintaining protection. GENERAL NOTES Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Roof Access Room Original Comment: replace missing ceiling and hatch. Fire sprinkler will not function properly without ceiliing holding heat. JEFF SIEBEL - 04/07/2025 @ 09:53 Annual inspection fee $610 REINSPECTION DATE 05/02/2025 CONTACT SIGNATURE Patrick Lynch 2025 Signed on: 04/07/2025 @ 09:54 Printed on 04/07/2025 @ 09:56 Page 3 of 4 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 04/07/2025 @ 09:55 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 04/07/2025 @ 09:56 Page 4 of 4