Loading...
HomeMy WebLinkAbout205 W 4TH STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/06/2025 03/10/2025 2025-00000264 $80.00 Customer #: 24382 Ariz 205 W 4th Street WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 205 W 4TH ST - 1-31-25 FOR BILLING INQUIRY: (319)291-4323 [ Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # 24382 BILLING DATE 02/06/2025 DUE DATE 03/10/2025 INVOICE # 2025-00000264 CHARGES $80.00 Less Prepayment Total Due —� City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT ARIZ RESTAURANT, 205 W 4TH ST, BLDG 205 W 4TH ST, WATERLOO /A 50702 DETAILS Inspection Date: 01/31/2025 ! Inspection Type: Annual Inspection (1Yr) ( Inspection Number: 12366 Shift: N/A I Station: N/A Unit: N/A ( Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 34 I Violations: 10 ( N/A Codes: 33 STATUS CODE DESCRIPTION FAIL 102.4 - Application of building The design and construction of new structures shall comply with the code. International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Location: kitchen under dishwasher counter Original Comment: remove water heater or obtain proper permits and inspections. Currently Burn Hazard FAIL 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Location: Party room exit Original Comment: remove bench from restricted exit path. Printed on 02/03/2023 @ 11:13 Page 1 of 5 STATUS CODE DESCRIPTION FAIL 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. FAIL FAIL 603.5 - Relocatable power taps and current taps.Multiplug adapters. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Location: Exit from kitchen Original Comment: remove obstructions ( washer/dryer) from exit path Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: party room Original Comment: remove multiplug adapter from cooler and stereo. Cooler must plug directly into permanent wall outlet. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: Office Original Comment: Remove extenstion cord from door. Remove multiplug adapter. Light duty office equipt may plug into power strip with a reset button. Printed on 02/03/2025 @ 11:13 Page 2 of 5 STATUS CODE DESCRIPTION FAft 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Behind cigar bar liquor display Original Comment: remove extension cord . Install permanent power with permits and inspections. FAIL 603.8 - Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting installations shall not exceed is allowed for a period not to exceed of 90 days. Temporary wiring methods shall meet the applicable provisions of NFPA 70. Exception: Temporary wiring for electrical power and lighting installations is allowed complying with the applicable provisions of NFPA 70 is permitted during periods of construction, remodeling, repair or demolition of buildings, structures, equipment or similar activities. Location: Inside and outside. Original Comment: decorative temporary lighting must be removed after 90 days. Remove all extension cords and associated temporary wiring today. FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: kitchen hood exhaust system cleaning inspection Original Comment: Provide kitchen hood exhaust system cleaning inspection report with all discrepancies corrected. Currently 292 days past due. Contractor must upload online to the compliance enging. Printed on 02/03/2025 @ 11:13 Page 3 of 5 STATUS CODE DESCRIPTION FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: Kitchen hood fire suppression inspection Original Comment: Provide kitchen hood exhaust system fire suppression inspection report with all discrepancies corrected. Currently 201 days past due. Contractor must upload online to the compliance enging. FAIL 903.3.3 - Obstructed Automatic sprinklers shall be installed with regard to obstructions that will delay locations. activation or obstruct the water distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used. Automatic sprinklers shall be installed in or under covered kiosks, displays, booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width. Not less than a 3-foot (914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire -extinguishing system in accordance with Section 904. Location: By old pool exit Original Comment: remove curtain causing fire sprinkler obstruction. Curtain must be fire rated. GENERAL NOTES JEFF SIEBEL - 02/03/2025 @ 11:06 annua inspection $80 REINSPECT/ON DATE 02/21/2025 Printed on 02/03/2025 @ 11:13 Page 4 of 5 CONTACT SIGNATURE Aurion Redding Signed on: 02/03/2025 @ 11:11 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 02/03/2025 @ 11:12 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/03/2025 @ 11:13 Page 5 of 5