COMMERCIAL INSPECTION - 1415 E SAN MARNAN DR - 1-30-25
FOR BILLING INQUIRY: (319)291-4323
L Description
INSPECTION 2,000
OCCUPANCY FEE
Total Price j
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
22675
02/06/2025
03/10/2025
2025-00000263
$80.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
AMIGOS 2,1415 E SAN MARNAN DR, BLDG 1415 E SAN MARNAN DR, WATERLOO /A 50702
DETAILS
Inspection Date:
Unit: N/A ( Lead
Inspection Type: Annual Inspection (1 Inspe . on Number: 12780 Shift: N/A I Station: N/A j
JEFF SIEBEL I Other Inspectors: N/A
VIOLATIONS AND COMPLIANCES
Showing only violations and images for this inspection. Please reach out to the lead inspector for more details.
Resolved Violations: 0 I Passed Codes: 26 I Violations: 9 I N/A Codes: 42
STATUS CODE DESCRIPTION
FAIL 102.4 - Application of building The design and construction of new structures shall comply with the
code. International Building Code , and any alterations, additions, changes in use or
changes in structures required by this code, which are within the scope of the
International Building Code , shall be made in accordance therewith.
Location: Water Heater
Original Comment: Provide water heater permit and inspections
Printed on 01/30/2025 @ 15:40
Page 1 of 6
STATUS CODE DESCRIPTION
FAI L
FAI L
5303.5.3 - Securing
compressed gas containers,
cylinders and tanks.
Compressed gas containers, cylinders and tanks shall be secured to prevent
fa►ling caused by contact, vibration or seismic activity. Securing of compressed
gas containers, cylinders and tanks shall be by one of the following methods:
1.Securing containers, cylinders and tanks to a fixed object with one or more
restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile
device designed for the movement of compressed gas containers, cylinders or
tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container
filling or servicing facilities or in sellers' warehouses not open to the public.
Nesting shall be allowed provided that the nested containers, cylinders or tanks,
if dislodged, do not obstruct the required means of egress. 4.Securing of
compressed gas containers, cylinders and tanks to or within a rack, framework,
cabinet or similar assembly designed for such use. Exception: Compressed gas
containers, cylinders and tanks in the process of examination, filling, transport or
servicing.
Location: kitchen and water heater room
Original Comment: secure compressed gas cylinders with CHAIN.
603.2 - Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical
conditions and electrical conditions in permanent wiring shall be brought to the attention of the
hazards. responsible code official. Electrical wiring, devices, appliances and other
equipment that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated not be used.
Location: ceiling can lights with receptacle adapters for lights
Original Comment: remove receptacle adapters . Install permanent wiring
Printed on 01/30/2025 @ 15:40
Page 2 of 6
STATUS CODE DESCRIPTION
FAI L
603.2 -Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical
conditions and electrical conditions in permanent wiring shall be brought to the attention of the
hazards. responsible code official. Electrical wiring, devices, appliances and other
equipment that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated not be used.
Location: walk in cooler
Original Comment: remove improper bulb in light fixture and install proper bulb
and moisture proof cover.
FAIL 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors,
under doors or floor coverings, or be subject to environmental or physical
damage.
FAIL
603.6 - Extension cords.
Location: Center dining area
Original Comment: remove cord for multi -colored light for art work from ceiling
Extension cords and flexible cordsshall not be a substitute for permanent wiring
and shall be listed and labeled in accordance with UL 817. Extension cords and
flexible cordsshall not be affixed to structures, extended through walls, ceilings
or floors, or under doors or floor coverings, nor shall such cords be subject to
environmental damage or physical impact. Extension cords shall be used only
with portable appliances. Extension cords marked for indoor use shall not be
used outdoors.
Location: outdoors to amigos sign on patio
Original Comment: remove extension cord and multiplug adapter to outdoor
sign. Install permanent power. Confirm power strip for outdoor lights is rated for
outdoor use.
Printed on 01/30/2025 @ 15:40
Page 3 of 6
STATUS
FAIL
CODE DESCRIPTION
606.3.3.3 - Records.
Records for inspections shall state the individual and company performing the
inspection, a description of the inspection and when the inspection took place.
Records for cleanings shall state the individual and company performing the
cleaning and when the cleaning took place. Such records shall be completed after
each inspection or cleaning and maintained.
Location: Kitchen hood exhaust sytem cleaning
Original Comment: Provide current semi-annual kitchen hood exhaust system
cleaning inspection report with all deficiencies corrected. Currently 168 days past
due. Contractor must upload online to the compliance engine.
FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the
inspection, a description of the inspection and when the inspection took place.
Records for cleanings shall state the individual and company performing the
cleaning and when the cleaning took place. Such records shall be completed after
each inspection or cleaning and maintained.
Location: kitchen hood fire suppression inspection
Original Comment: Provide current semi-annual kitchen hood exhaust system
fire suppression inspection report with all deficiencies corrected. Currently 168
days past due. Contractor must upload online to the compliance engine.
Printed on 01 /30/2025 @ 15:40
Page 4of6
STATUS CODE DESCRIPTION
FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in
accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to
reach an extinguisher shall not apply to the spectator seating portions of Group
A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance
shall be allowed to be once every 3 years for dry -chemical or halogenated agent
portable fire extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the following conditions are
met: 2.1.Electronic monitoring shall confirm that extinguishers are properly
positioned, properly charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a trouble signal.
2.3.The extinguishers shall be installed inside of a building or cabinet in a
noncorrosive environment. 2.4.Electronic monitoring devices and supervisory
circuits shall be tested every 3 years when extinguisher maintenance is
performed. 2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at
the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers
shall be permitted to be located at staff locations.
Location: front hostess area
Original Comment: provide annual service for fire extinguisher . All extinguishers
are due in March.
GENERAL NOTES
JEFF SIEBEL - 01/30/2025 @ 15:29 annual inspection $80
REINSPECTION DATE
02/20/2025
CONTACT SIGNATURE
Oscar Valdivia
Signed on: 01/30/2025 @ 15:28
Printed on 01/30/2025 @ 15:40
Page 5 of 6
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on: 01/30/2025 @ 15:29
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Vrinted on 01/30/2025 @ 15 40
Page 6 of 6