Loading...
HomeMy WebLinkAbout1415 E SAN MARNAN DRINVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/06/2025 03/10/2025 2025-00000263 $80.00 Customer #: 22675 AMIGOS 1415 E SAN MARNAN DR WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1415 E SAN MARNAN DR - 1-30-25 FOR BILLING INQUIRY: (319)291-4323 L Description INSPECTION 2,000 OCCUPANCY FEE Total Price j $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 22675 02/06/2025 03/10/2025 2025-00000263 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT AMIGOS 2,1415 E SAN MARNAN DR, BLDG 1415 E SAN MARNAN DR, WATERLOO /A 50702 DETAILS Inspection Date: Unit: N/A ( Lead Inspection Type: Annual Inspection (1 Inspe . on Number: 12780 Shift: N/A I Station: N/A j JEFF SIEBEL I Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 26 I Violations: 9 I N/A Codes: 42 STATUS CODE DESCRIPTION FAIL 102.4 - Application of building The design and construction of new structures shall comply with the code. International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Location: Water Heater Original Comment: Provide water heater permit and inspections Printed on 01/30/2025 @ 15:40 Page 1 of 6 STATUS CODE DESCRIPTION FAI L FAI L 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent fa►ling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Location: kitchen and water heater room Original Comment: secure compressed gas cylinders with CHAIN. 603.2 - Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions and electrical conditions in permanent wiring shall be brought to the attention of the hazards. responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Location: ceiling can lights with receptacle adapters for lights Original Comment: remove receptacle adapters . Install permanent wiring Printed on 01/30/2025 @ 15:40 Page 2 of 6 STATUS CODE DESCRIPTION FAI L 603.2 -Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions and electrical conditions in permanent wiring shall be brought to the attention of the hazards. responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Location: walk in cooler Original Comment: remove improper bulb in light fixture and install proper bulb and moisture proof cover. FAIL 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. FAIL 603.6 - Extension cords. Location: Center dining area Original Comment: remove cord for multi -colored light for art work from ceiling Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: outdoors to amigos sign on patio Original Comment: remove extension cord and multiplug adapter to outdoor sign. Install permanent power. Confirm power strip for outdoor lights is rated for outdoor use. Printed on 01/30/2025 @ 15:40 Page 3 of 6 STATUS FAIL CODE DESCRIPTION 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: Kitchen hood exhaust sytem cleaning Original Comment: Provide current semi-annual kitchen hood exhaust system cleaning inspection report with all deficiencies corrected. Currently 168 days past due. Contractor must upload online to the compliance engine. FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: kitchen hood fire suppression inspection Original Comment: Provide current semi-annual kitchen hood exhaust system fire suppression inspection report with all deficiencies corrected. Currently 168 days past due. Contractor must upload online to the compliance engine. Printed on 01 /30/2025 @ 15:40 Page 4of6 STATUS CODE DESCRIPTION FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: front hostess area Original Comment: provide annual service for fire extinguisher . All extinguishers are due in March. GENERAL NOTES JEFF SIEBEL - 01/30/2025 @ 15:29 annual inspection $80 REINSPECTION DATE 02/20/2025 CONTACT SIGNATURE Oscar Valdivia Signed on: 01/30/2025 @ 15:28 Printed on 01/30/2025 @ 15:40 Page 5 of 6 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 01/30/2025 @ 15:29 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Vrinted on 01/30/2025 @ 15 40 Page 6 of 6