Loading...
HomeMy WebLinkAbout1975 FRANKLIN STINVOICE DATE DUE DATE INVOICE it TOTAL DUE 02/06/2025 03/10/2025 2025-00000260 $80.00 Customer #: 21926 RAY'S SUPERMARKET INC 1975 FRANKLIN ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1975 FRANKLIN ST - 1-29-25 FOR BILLING INQUIRY: (319)291-4323 [ Description INSPECTION 2,000 OCCUPANCY FEE Total Price J $70.00 $10.00 CUSTOMER # 21926 BILLING DATE 02/06/2025 DUE DATE 03/10/2025 INVOICE # 2025-00000260 CHARGES $80.00 Less Prepayment Total Due — City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT mars SUPER MARKET, 1975 FRANKLIN ST, BLDG 1975 FRANKLIN ST, WATERLOO IA 50703 DETAILS Inspect /n Date: 01/29/2025 I Irspection Type: Annual Inspection (1 Yr) I I spection Number: 12710/I Shift: N/A I Station: N/A Unit: /A I Lead Inspector: JEfj!EMIAH VANDYKE I Other Inspectors: N/A I Fee: $80.00 VIOLATIONS AND4O9PLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 29 I Violations: 14 I N/A Codes: 31 STATUS CODE FAIL 1010.1.3 - Door opening force Forces to unlatch and open doors. DESCRIPTION The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch - pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2,For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Location: Door leading into alley. Original Comment: Door was blocked and hard to open from dirt pushed up against door. Printed on O1 /29/2025 @ 16:58 Page 1 of 8 STATUS CODE DESCRIPTION FAI L FAIL 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in illumination. accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 - Exit signs. Location: Basement Egress Tight at bottom of steps. Original Comment: Egress light tested and failed. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: North door going out to Alley. Original Comment: Exit/Egress light tested and failed. 603.2 - Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions and electrical conditions in permanent wiring shall be brought to the attention of the hazards. responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Location: Cord between video games. Original Comment: Power cord for bigger video game needs tape removed and covered with UL listed power cord protector. Printed on 01/29/2025 @ 16:58 Page 2 of 8 STATUS CODE FAIL FAI L DESCRIPTION 603.2 - Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions and electrical conditions in permanent wiring shaft be brought to the attention of the hazards. responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2.2 - Unapproved conditionsOpen electrical terminations. Location: North side cooler inside lights. Original Comment: Glass cover for lighting fixture inside cooler is filled with water and needs to be repaired. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Outside on south wall. Original Comment: Cover plate needed on box. Printed on 01/29/2025 @ 16:58 Page 3 of 8 STATUS FAIL FAIL CODE 603.5 - Relocatable power taps and current taps.Multiplug adapters. 606.3.3 - Cleaning. DESCRIPTION Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: Near cooking area in back. Original Comment: Electric fryers plugged into power strip. Electric oil fryers must be under hood suppression system or removed. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. Location: Commercial Kitchen Exhaust Cleaning Original Comment: Hood cleaning is 20 days past due. Need to be cleaned by contractor and uploaded to compliance engine by contractor. Printed an O1 /29/202 5 @ 16:58 Page 4 of 8 STATUS CODE DESCRIPTION FAIL 606.3.3.1 - Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. Location: Commercial Kitchen Exhaust Cleaning Original Comment: Hood cleaning is 20 days past due. Need to be cleaned by contractor and uploaded to compliance engine by contractor. FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: Hood suppression and hood cleaning both past due Original Comment: Hood suppression and hood cleaning both past due. Must contact contractors to clean and inspect. FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Multiple ceiling tiles missing. Original Comment: Ceiling tiles need to be replaced. Printed on 01/29/2025 @ 16:58 Page 5 of 8 STATUS CODE DESCRIPTION FAIL 904.13.5.2 - Extinguishing Automatic fire -extinguishing systems shall be serviced not Tess frequently than every six months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. system service. Location: Hood Suppression System ia Past Due 235 days. Original Comment: Hood Suppression System ia Past Due 235 days. Needs to inspected by licensed contractor and report uploaded by contractor to compliance engine. FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: All fire extinguishers in building including basement. Original Comment: Fire extinguishers need to be serviced and tagged by contractor. Printed on 01/29/2025 @ 16:58 Page 6 of 8 STATUS CODE DESCRIPTION )l, 906.4.2 - Class K portable fire Where hazard areas include deep fat fryers, listed Class K portable fire extinguishers for deep fat extinguishers shall be provided as follows: 1.For up to four fryers having a fryers. maximum cooking medium capacity of 80 pounds (36.3 kg) each: one Class K portable fire extinguisher of a minimum 1.5-gallon ( 6 L) capacity. 2.For every additional group of four fryers having a maximum cooking medium capacity of 80 pounds (36.3 kg) each: one additional Class K portable fire extinguisher of a minimum 1.5-gallon (6 L) capacity shall be provided. 3.For individual fryers exceeding 6 square feet (0.55 m2) in surface area: Class K portable fire extinguishers shall be installed in accordance with the extinguisher manufacturer's recommendations. GENERAL NOTES JEREMIAH VANDYKE-01/29/2025 @ 16:47 Location: Class K fire extinguisher in kitchen area is past due. Original Comment: Class K fire extiguisher needs to be serviced. Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees may be assessed for subsequent re - inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 01/29/2025 @ 16:47 Lt. Van Dyke-jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883- 1615 JEREMIAH VANDYKE - 01/29/2025 @ 16:48 Inspection Fee = $80.00 (To be mailed out by City via snail mail.) REINSPECTION DATE 02/28/2025 CONTACT SIGNATURE Yasmine Yasmeen Reason for not collecting a signature: Person not available for signature Printed on 01/29/2025 @ 16:58 Page 7 of 8 INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on: 01/29/2025 @ 16:57 QUESTIONS ABOUT YOUR ►NSPECT►ON? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 01 /29/2025 // 16:58 Page 8 of 8