COMMERCIAL INSPECTION - 1975 FRANKLIN ST - 1-29-25
FOR BILLING INQUIRY: (319)291-4323
[ Description
INSPECTION 2,000
OCCUPANCY FEE
Total Price J
$70.00
$10.00
CUSTOMER #
21926
BILLING DATE
02/06/2025
DUE DATE
03/10/2025
INVOICE #
2025-00000260
CHARGES
$80.00
Less Prepayment
Total Due —
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
mars SUPER MARKET, 1975 FRANKLIN ST, BLDG 1975 FRANKLIN ST, WATERLOO IA 50703
DETAILS
Inspect /n Date: 01/29/2025 I Irspection Type: Annual Inspection (1 Yr) I I spection Number: 12710/I Shift: N/A I Station: N/A
Unit: /A I Lead Inspector: JEfj!EMIAH VANDYKE I Other Inspectors: N/A I Fee: $80.00
VIOLATIONS AND4O9PLIANCES
Showing only violations and images for this inspection. Please reach out to the lead inspector for more details.
Resolved Violations: 0 I Passed Codes: 29 I Violations: 14 I N/A Codes: 31
STATUS CODE
FAIL
1010.1.3 - Door opening
force Forces to unlatch and
open doors.
DESCRIPTION
The force for pushing or pulling open interior swinging egress doors, other than
fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the
force required to retract latch bolts or disengage other devices that hold the
door in a closed position. For other swinging doors, as well as sliding and folding
doors, the door latch shall release when subjected to a 15-pound (67 N) force.
The door shall be set in motion when subjected to a 30-pound (133 N) force. The
door shall swing to a full -open position when subjected to a 15-pound (67 N)
force. The forces to unlatch doors shall comply with the following: 1.Where door
hardware operates by push or pull, the operational force to unlatch the door
shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by
rotation, the operational force to unlatch the door shall not exceed 28 inch -
pounds (315 N-cm). The force to open doors shall comply with the following: 1.For
interior swinging egress doors that are manually operated, other than doors
required to be fire rated, the force for pushing or pulling open the door shall not
exceed 5 pounds (22 N). 2,For other swinging doors, sliding doors or folding
doors, and doors required to be fire rated, the door shall require not more than
a 30-pound (133 N) force to be set in motion and shall move to a full -open
position when subjected to not more than a 15-pound (67 N) force.
Location: Door leading into alley.
Original Comment: Door was blocked and hard to open from dirt pushed up
against door.
Printed on O1 /29/2025 @ 16:58
Page 1 of 8
STATUS CODE DESCRIPTION
FAI L
FAIL
1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in
illumination. accordance with Sections 1008.3 and 1104.5.1.
1203.2.6 - Exit signs.
Location: Basement Egress Tight at bottom of steps.
Original Comment: Egress light tested and failed.
Emergency power shall be provided for exit signs as required in Section 1013.6.3.
The system shall be capable of powering the required load for a duration of not
less than 90 minutes.
Location: North door going out to Alley.
Original Comment: Exit/Egress light tested and failed.
603.2 - Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical
conditions and electrical conditions in permanent wiring shall be brought to the attention of the
hazards. responsible code official. Electrical wiring, devices, appliances and other
equipment that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated not be used.
Location: Cord between video games.
Original Comment: Power cord for bigger video game needs tape removed and
covered with UL listed power cord protector.
Printed on 01/29/2025 @ 16:58
Page 2 of 8
STATUS CODE
FAIL
FAI L
DESCRIPTION
603.2 - Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical
conditions and electrical conditions in permanent wiring shaft be brought to the attention of the
hazards. responsible code official. Electrical wiring, devices, appliances and other
equipment that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated not be used.
603.2.2 - Unapproved
conditionsOpen electrical
terminations.
Location: North side cooler inside lights.
Original Comment: Glass cover for lighting fixture inside cooler is filled with water
and needs to be repaired.
Open junction boxes and open -wiring splices shall be prohibited. Approved
covers shall be provided for all switch and electrical outlet boxes.
Location: Outside on south wall.
Original Comment: Cover plate needed on box.
Printed on 01/29/2025 @ 16:58
Page 3 of 8
STATUS
FAIL
FAIL
CODE
603.5 - Relocatable power
taps and current
taps.Multiplug adapters.
606.3.3 - Cleaning.
DESCRIPTION
Multiplug adapters, such as cube adapters, unfused plug strips or any other
device not complying with NFPA 70 shall be prohibited. The construction and use
of current taps and relocatable taps shall be in accordance with NFPA 70 and this
code.
Location: Near cooking area in back.
Original Comment: Electric fryers plugged into power strip. Electric oil fryers must
be under hood suppression system or removed.
Hoods, grease -removal devices, fans, ducts and other appurtenances shall be
cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3.
Location: Commercial Kitchen Exhaust Cleaning
Original Comment: Hood cleaning is 20 days past due. Need to be cleaned by
contractor and uploaded to compliance engine by contractor.
Printed an O1 /29/202 5 @ 16:58
Page 4 of 8
STATUS CODE DESCRIPTION
FAIL 606.3.3.1 - Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be
inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code
official. Inspections shall be completed by qualified individuals.
Location: Commercial Kitchen Exhaust Cleaning
Original Comment: Hood cleaning is 20 days past due. Need to be cleaned by
contractor and uploaded to compliance engine by contractor.
FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the
inspection, a description of the inspection and when the inspection took place.
Records for cleanings shall state the individual and company performing the
cleaning and when the cleaning took place. Such records shall be completed after
each inspection or cleaning and maintained.
Location: Hood suppression and hood cleaning both past due
Original Comment: Hood suppression and hood cleaning both past due. Must
contact contractors to clean and inspect.
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: Multiple ceiling tiles missing.
Original Comment: Ceiling tiles need to be replaced.
Printed on 01/29/2025 @ 16:58
Page 5 of 8
STATUS
CODE
DESCRIPTION
FAIL 904.13.5.2 - Extinguishing Automatic fire -extinguishing systems shall be serviced not Tess frequently than
every six months and after activation of the system. Inspection shall be by
qualified individuals, and a certificate of inspection shall be forwarded to the fire
code official upon completion.
system service.
Location: Hood Suppression System ia Past Due 235 days.
Original Comment: Hood Suppression System ia Past Due 235 days. Needs to
inspected by licensed contractor and report uploaded by contractor to
compliance engine.
FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in
accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to
reach an extinguisher shall not apply to the spectator seating portions of Group
A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance
shall be allowed to be once every 3 years for dry -chemical or halogenated agent
portable fire extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the following conditions are
met: 2.1.Electronic monitoring shall confirm that extinguishers are properly
positioned, properly charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a trouble signal.
2.3.The extinguishers shall be installed inside of a building or cabinet in a
noncorrosive environment. 2.4.Electronic monitoring devices and supervisory
circuits shall be tested every 3 years when extinguisher maintenance is
performed. 2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at
the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers
shall be permitted to be located at staff locations.
Location: All fire extinguishers in building including basement.
Original Comment: Fire extinguishers need to be serviced and tagged by
contractor.
Printed on 01/29/2025 @ 16:58
Page 6 of 8
STATUS CODE DESCRIPTION
)l, 906.4.2 - Class K portable fire Where hazard areas include deep fat fryers, listed Class K portable fire
extinguishers for deep fat extinguishers shall be provided as follows: 1.For up to four fryers having a
fryers. maximum cooking medium capacity of 80 pounds (36.3 kg) each: one Class K
portable fire extinguisher of a minimum 1.5-gallon ( 6 L) capacity. 2.For every
additional group of four fryers having a maximum cooking medium capacity of 80
pounds (36.3 kg) each: one additional Class K portable fire extinguisher of a
minimum 1.5-gallon (6 L) capacity shall be provided. 3.For individual fryers
exceeding 6 square feet (0.55 m2) in surface area: Class K portable fire
extinguishers shall be installed in accordance with the extinguisher
manufacturer's recommendations.
GENERAL NOTES
JEREMIAH VANDYKE-01/29/2025 @ 16:47
Location: Class K fire extinguisher in kitchen area is past due.
Original Comment: Class K fire extiguisher needs to be serviced.
Re -inspection dates are automatically generated 30 days out from the initial
inspection. Normal operating hours for inspections & re -inspections are Monday -
Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on
a weekend, the re -inspection will typically be performed the following Monday or
Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier
re -inspection. *****Re inspection fees may be assessed for subsequent re -
inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent
re-inspections.-
JEREMIAH VANDYKE - 01/29/2025 @ 16:47 Lt. Van Dyke-jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-
1615
JEREMIAH VANDYKE - 01/29/2025 @ 16:48 Inspection Fee = $80.00 (To be mailed out by City via snail mail.)
REINSPECTION DATE
02/28/2025
CONTACT SIGNATURE
Yasmine Yasmeen Reason for not collecting a signature: Person not available for signature
Printed on 01/29/2025 @ 16:58
Page 7 of 8
INSPECTOR SIGNATURE
JEREMIAH VANDYKE
Signed on: 01/29/2025 @ 16:57
QUESTIONS ABOUT YOUR ►NSPECT►ON?
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org
No phone number available
Printed on 01 /29/2025 // 16:58
Page 8 of 8