Loading...
HomeMy WebLinkAbout1221 FRANKLIN ST7 V I INVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/17/2025 03/20/2025 2025-00000269 $80.00 Customer #: 21820 LA MICHOACANA RESTAURANT 1221 FRANKLIN ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1221 FRANKLIN ST - 2-13-25 [ Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 2,000 OCCUPANCY FEE Total Price j $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 21820 02/17/2025 03/20/2025 2025-00000269 $80.00 Less Prepayment Total Due —* City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT MICHOACANA, 1221 FRANKLIN sr, BLDG 1221 FRANKLIN ST, WATERLOO /A S0703 DETAILS Inspection Date: 02/13/2025 ( Inspection Type: Annual Inspection (1 Yr) ( Inspection Number: 12857 Shift: N/A I Station: N/A Unit: N/A Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A I Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 34 I Violations: 5 I N/A Codes: 36 STATUS CODE DESCRIPTION FAIL 1004.9 - Posting of occupant Every room or space that is an assembly occupancy shall have the occupant load load. of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space, for the intended configurations. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or the owner's authorized agent. FAIL 603.2.2 - Unapproved conditionsOpen electrical terminations. Location: By front entrance Original Comment: Post Occupant Load Sign that was provided by fire inspector by front entrance Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Behind cooler in front of electrical panel closet Original Comment: install outlet cover. Pr on 02/14/202S @ 13:10 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Electrical Panel Closet Original Comment: Unable to access electrical panels by opening doors because of cooler and storage in front of doors. Both doors must be openable to give full access to both panels. FAIL 606.2 - Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Exceptions: 1.Factory-built commercial exhaust hoods that are listed and labeled in accordance with UL 710, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2.Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 710B, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code. For the purpose of determining the floor area required to be ventilated, each individual appliance shall be considered as occupying not less than 100 square feet (9.3 m2). 3.Where cooking appliances are equipped with integral down -draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96, a hood shall not be required at or above them. 4.A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mg/m3 or less of grease when tested at an exhaust flow rate of 500 cfm (0.236 m3/s) in accordance with UL 710B. Location: Kitchen Original Comment: 6 Burner range must be under Type 1 hood with at least a 6" overlap and protected by fire suppression system. Move range under hood. Printed on 02/14/2025 0 13:10 Page 2 of 4 STATUS FAI L CODE 606.3.3.3 - Records. GENERAL NOTES JEFF SIEBEL - 02/14/2025 @ 11:14 JEFF SIEBEL - 02/14/2025 @ 11:14 REINSPECTION DATE 03/14/2025 CONTACT SIGNATURE Blanca Garcia Signed on: 02/14/2025 @ 13:06 DESCRIPTION Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: Kitchen Hood Exhaust Cleaning Inspection Report Original Comment: Provide documentation of kitchen hood exhaust system inspection report with all discrepancies corrected. Currently 22 days past due. Contractor must upload report online to the compliance engine. annual inspectoin $80 kitchen hood fire suppression inspection due 3/5/25 Printed on 02/14/2025 @ 13:10 Page 3 of 4 INSPECTORSIGNATURE JEFF SIEBEL Signed on: 02/14/2025 @ 13:06 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/14/2025 @ 13:10 Page 4 of 4