Loading...
HomeMy WebLinkAbout1615 BISHOP AVEu .,iiar,.., 1 ... 1 11 1 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/17/2025 03/20/2025 2025-00000267 $100.00 Customer #: 20738 B & B EAST 1615 BISHOP AV WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1615 BISHOP AVE - 3-11-25 [ Description FOR BILLING INQUIRY: (319)291-4323 REINSPECTION 1 Total Price ] $100.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 20738 02/17/2025 03/20/2025 2025-00000267 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT B & B EAST, 1615 BISHOP AVE, BLDG 1615 BISHOP AVE, WATERLOO /A 50707 DETAILS Inspection Date: 03/11/2025 j Inspection Type: Annual Inspection (1Yr) 1 Inspection Number: 12364-R1 I Shift: N/A Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL ( Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 2 I Passed Codes: 0 I Violations: 4 1 N/A Codes: 0 STATUS CODE DESCRIPTION FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: above front door Original Comment: Repair exit/egress light FAIL 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Location: walk path by display case Original Comment: Power cord must be protected by listed cord protector. Printed on 02/14/2025 @ 14:17 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 606.2 - Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Exceptions: 1.Factory-built commercial exhaust hoods that are listed and labeled in accordance with UL 710, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2.Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 710B, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code. For the purpose of determining the floor area required to be ventilated, each individual appliance shall be considered as occupying not Tess than 100 square feet (9.3 m2). 3.Where cooking appliances are equipped with integral down -draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96, a hood shall not be required at or above them. 4.A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mg/m3 or less of grease when tested at an exhaust flow rate of 500 cfm (0.236 m3/s) in accordance with UL 710B. Location: outside hood on counter Original Comment: electric fry pan must be under kitchen hood and protected by fire protection system. Additional Comment: Now griddle is outside of hood and fire suppression system. Printed on 02/14/2025 @ 14:17 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 606.2 - Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Exceptions: 1.Factory-built commercial exhaust hoods that are listed and labeled in accordance with UL 710, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2.Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 710B, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code. For the purpose of determining the floor area required to be ventilated, each individual appliance shall be considered as occupying not less than 100 square feet (9.3 m2). 3.Where cooking appliances are equipped with integral down -draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96, a hood shall not be required at or above them. 4.A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mg/m3 or less of grease when tested at an exhaust flow rate of 500 cfm (0.236 m3/s) in accordance with UL 710B. Location: Kitchen hood Original Comment: Large chicken fryer must be 6" under hood to avoid flame roll out in the event of a fire. GENERAL NOTES JEFF SIEBEL - 02/14/2025 @ 14:16 re -inspection fee $100 JEFF SIEBEL - 01/29/2025 @ 15:26 annual inspection $80 JEFF SIEBEL - 01/29/2025 @ 15:26 Gas pump 2 out of service. JEFF SIEBEL - 01/29/2025 @ 15:26 Gas Line Alarm on monitor is in alarm mode. Rectify problem. REINSPECT/ON DATE 03/13/2025 Printed on 02/14/2025 @ 14:17 Page 3 of 4 CONTACT SIGNATURE Muhammad Sarwar Signed on: 02/14/2025 @ 14:11 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 02/14/2025 @ 14:11 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/14/2025 @ 14:17 Page 4 of 4