Loading...
HomeMy WebLinkAbout2026 BOPP STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/25/2025 03/30/2025 2025-00000285 $80.00 Customer #: 24679 POPPY'S SPORTS PUB 2026 BOPP WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2026 BOPP ST - 2-20-25 FOR BILLING INQUIRY: (319)291-4323 [Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24679 02/25/2025 03/30/2025 2025-00000285 $80.00 Less Prepayment Total Due — > City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT POPPY'S SPORTS PUB, 2026 BOPP ST, BLD6 2026 BOPP ST, WATERLOO /A S0702 DETAILS Inspection Date: 02/20/2025 j Inspection Type: Annual Inspection (1 Yr) I Inspection Number: 13019 Shift: N/A I Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A j Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 28 I Violations: 6 I N/A Codes: 40 STATUS CODE DESCRIPTION FAIL 1032.3 - Obstructions. A means of egress shall be free from obstructions that would prevent its use, including the accumulation of snow and ice. Location: rear exit Original Comment: remove snow, door must unlatch and swing to full open with less than 15# force. FAIL 304.3.1 - Spontaneous Materials susceptible to spontaneous ignition, such as oily rags, shall be stored in ignition. a listed disposal container. Contents of such containers shall be removed and disposed of daily. Location: Not Provided Original Comment: Provide an approved listed oily waste container for all grease laden materials. See attached Printed on 02/21 /202 5 @ 15:40 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: Kitchen hood fire suppressin system inspection Original Comment: Provide current semi-annual kitchen hood fire suppression system inspection report with all discrepancies. Currently 116 days past due. Contractor must upload online to the compliance engine. FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: Kitchen hood cleaning inspspection report Original Comment: Provide current semi-annual kitchen hood fire cleaning inspection report with all discrepancies. Currently 116 days past due. Contractor must upload online to the compliance engine. Printed on 02/21/2025 @ 15:40 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Not Provided Original Comment: provide annual service for fire extinguishers. FAIL 906.6 - Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view. In unobscured. rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. GENERAL NOTES JEFF SIEBEL - 02/21/2025 @ 15:38 JEFF SIEBEL - 02/21/2025 @ 15:39 REINSPECT/ON DATE 03/17/2025 Location: kitchen by door Original Comment: remove obstructions to fire extinguisher. annual inspection fee $80 Call if completed before re -inspection date and for final inspection before opening. Printed on 02/21 /2025 @ 15:40 Page 3 of 4 CONTACT SIGNATURE Shannon Jones Signed on: 02/21/2025 @ 15:38 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 02/21/2025 @ 15:38 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 1-J6:ce S ` Printed on 02/21/2025 @ 1 Ci:40 Page 4 of 4