Loading...
HomeMy WebLinkAbout206 E 4TH STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/25/2025 03/30/2025 2025-00000284 $80.00 Customer #: 24678 HUNGRY CHARLES 206E 4TH ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 206 E 4TH-2-20-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24678 02/25/2025 03/30/2025 2025-00000284 $80.00 Less Prepayment Total Due —► City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT HUNGRY CHARLIES LUNCHBOX 206 E 4TH ST, BLDG 206 E 4TH ST, WATERLOO IA 50703 DETAILS Inspection Date: 02/20/2025 I Inspection Type: Annual Inspection (1Yr) I Inspection Number: 16188 ; Shift: N/A Station: Station 1 Fire Headquarters I Unit: N/A ( Lead Inspector: JEFF SIEBEL Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 39 I Violations: 8 I N/A Codes: 29 STATUS CODE FAIL DESCRIPTION 2015 IFC - Fire alarm testing Is the fire alarm system powered, operational and displaying normal operation and maintenance (no troubles, supervisory, or alarms)? Location: Fire Alarm Annunciator Panel Original Comment: Panel shows trouble -communications test failure. Provide documentation of correction. FAIL 304.3.1 - Spontaneous Materials susceptible to spontaneous ignition, such as oily rags, shall be stored in ignition. a listed disposal container. Contents of such containers shall be removed and disposed of daily. Location: Not Provided Original Comment: Provide LISTED approved oily waste container with self closing lid for all grease laden materials. See attachment Printed on 02/212025 @ 14:54 Page 1 of 5 STATUS CODE DESCRIPTION 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Location: Basement Original Comment: secure all compressed gas cylinders with chain or other approved tip over prevention device. FAIL 5701.1 - Scope and Prevention, control and mitigation of dangerous conditions related to storage, application. use, dispensing, mixing and handling of flammable and combustible liquids shall be in accordance with Chapter 50 and this chapter. Location: basement Original Comment: remove open diesel container with fuel in it from building FAIL 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: front window Original Comment: remove extension cord. Power strip with reset may be used for low wattage items such as led lights, computers etc. Anything with a motor or produces heat or cooling must be plugged directly into wall outlet. Printed on 02/21/2025 @ 14:54 Page 2 of 5 STATUS CODE DESCRIPTION FAIL 603.8 - Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting installations shall not exceed is allowed for a period not to exceed of 90 days. Temporary wiring methods shall meet the applicable provisions of NFPA 70. Exception: Temporary wiring for electrical power and lighting installations is allowed complying with the applicable provisions of NFPA 70 is permitted during periods of construction, remodeling, repair or demolition of buildings, structures, equipment or similar activities. Location: front window Original Comment: temporary light must be removed after 90 days use. FAIL 903.3.3 - Obstructed Automatic sprinklers shall be installed with regard to obstructions that will delay locations. activation or obstruct the water distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used. Automatic sprinklers shall be installed in or under covered kiosks, displays, booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width. Not less than a 3-foot (914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire -extinguishing system in accordance with Section 904. Location: Storage closet in hall Original Comment: reduce storage that is blocking fire sprinkler coverage. Printed on 02/21/2025 @ 14:54 Page 3 of 5 STATUS CODE DESCRIPTION FAIL 904.13 - Commercial cooking The automatic fire -extinguishing system for commercial cooking systems shall be systems. of a type recognized for protection of commercial cooking equipment and exhaust systems of the type and arrangement protected. Preengineered automatic dry- and wet -chemical extinguishing systems shall be tested in accordance with UL 300 and listed and labeled for the intended application. Other types of automatic fire -extinguishing systems shall be listed and labeled for specific use as protection for commercial cooking operations. The system shall be installed in accordance with this code, NFPA 96, its listing and the manufacturer's installation instructions. Automatic fire -extinguishing systems of the following types shall be installed in accordance with the referenced standard indicated, as follows: 1.Carbon dioxide extinguishing systems, NFPA 12.2. Automatic sprinkler systems, NFPA 13. 3.Automatic water mist systems, NFPA 750. 4.Foam-water sprinkler system or foam -water spray systems, NFPA 16. 5.Dry- chemical extinguishing systems, NFPA 17. 6.Wet-chemical extinguishing systems, NFPA 17A. Exception: Factory -built commercial cooking recirculating systems that are tested in accordance with UL 710B and listed, labeled and installed in accordance with Section 304.1 of the International Mechanical Code. GENERAL NOTES JEFF SIEBEL - 02/21/2025 @ 14:30 JEFF SIEBEL - 02/21/2025 @ 14:31 JEFF SIEBEL - 02/21/2025 @ 14:32 REINSPECTION DATE 03/12/2025 CONTACT SIGNATURE Daniel Corbett Signed on: 02/21/2025 @ 14:38 Location: Auto Fry Machine Original Comment: New Fryer must be connected to existing fire alarm system in compliance with NFPA 96. Alarm function must be acceptance tested with fire alarm contractor and fire inspector. Annual Inspection fee $80 Acceptance testing still required for Auto -Fry, however cleaning report is accepted. Annual fire sprinkler inspection due 3/14/25 Printed on 02/21/2025 @ 14:54 Page 4 of 5 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 02/21/2025 @ 14:38 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/21/2025 @ 14:54 Page 5 of 5