Loading...
HomeMy WebLinkAbout117 E SAN MARNAN DRINVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/25/2025 03/30/2025 2025-00000283 $80.00 Customer #: 24676 THE SPOT #3 117 E SAN MARNAN DR WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 117 E SAN MARNAN DR - 2-18-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # 24676 BILLING DATE 02/25/2025 DUE DATE 03/30/2025 City of Waterloo INVOICE # 2025-00000283 Less Prepayment Total Due —� CHARGES $80.00 $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. L-ik(r) WATERLOO FIRE RESCUE INSPECTION REPORT THE SPOT #3, 117 E SAN MARNAN DR, BLDG 117 E SAN MARNAN DR, WATERLOO IA 50702 DETAILS Inspection Date: 02/18/2025 I Inspection Type: Annual Inspection (1 Yr) I Inspection Number: 16174 j Shift: N/A I Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL j Other Inspectors: N/A I Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 16 I Violations: 11 I N/A Codes: 49 STATUS CODE DESCRIPTION FAI L 102.4 - Application of building The design and construction of new structures shall comply with the code. International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Location: storage room behind counter. Original Comment: Stop work issued. Obtain building permit and inspections for opening cut in wall behind counter and any electrica work completed for room Printed on 02/19/2025 @ 12:59 Page 1 of 7 STATUS CODE DESCRIPTION FAIL 102.4 - Application of building The design and construction of new structures shall comply with the code. International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. FAIL 1032.2 - Reliability. Location: Ceiling and back room Original Comment: Obtain electrical permit and inspections for new outlets, wiring, and lights. Have licensed electrician contact electical inspector Tim Moyer for requirements. 319-291-4319 Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Location: Back exit door in back storage room Original Comment: remove obstructions and maintain a clear path or contact Building Official Greg Ahlhelm 319-291-4319 to review if exit required or sign may be eliminated Printed on 02/19/2025 @ 12:59 Page 2 of 7 STATUS CODE DESCRIPTION FAIL 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Ceililng in Store Original Comment: Properly contain exposed wires in junction box with approved listed covers. FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70.2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Back room , by rear entrance and past restrooms on wall Original Comment: remove obstructions to electrical panel. Mainain a minimum of 36 minimum clearance. Printed on 02/19/2025 @ 12:59 Page 3 of 7 STATUS CODE DESCRIPTION FAIL 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. FAIL 603.6 - Extension cords. Location: Cooler to C4 Energy Cooler Original Comment: power strip hanging by cord. Must be properly mounted and plugged directly into wall outlet. Coolers not allowed on power strips, must plug directly into wall outlet. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: To Venom Energy by Front Counter Original Comment: Remove extension cord. Cooler must plug directly into permanent wall outlet. FAIL 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: New storage room Original Comment: remove extension cord. cooler must plug directly into permanent wall outlet. Printed on 02/19/2025 @ 12:59 Page 4 of 7 STATUS FAI L CODE 704.1 - Maintaining protection. DESCRIPTION Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1 Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Back room Original Comment: replace missing ceiling tile after electrical inspections complete. Printed on 02/19/2025 @ 12:59 Page 5 of 7 STATUS CODE DESCRIPTION FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: all fire extinguishers Original Comment: provide annual service for fire extinguishers. Last in 2023 FAIL 906.6 - Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view. In unobscured. rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. Location: back room by electrical panel Original Comment: remove obstructions, maintain a minimum of 36" clearances. GENERAL NOTES JEFF SIEBEL - 02/19/2025 @ 12:58 annual inspection $80 Printed on 02/19/2025 @ 12:59 Page 6 of 7 REINSPECTION DATE 03/11/2025 CONTACT SIGNATURE Abdul Awan Signed on: 02/19/2025 @ 12:56 INSPECTOR S►GNATURE JEFF SIEBEL Signed on: 02/19/2025 @ 12:56 QUESTIONS ABOUT YOUR ►NSPECT►ON? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 cL6 Printed on 02/19/2025 @ 12:59 Page 7 of 7