Loading...
HomeMy WebLinkAbout650 LA PORTE RDcrmuimanue y INVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/25/2025 03/30/2025 2025-00000277 $100.00 Customer #: 12606 CADILLAC LANES 650 LA PORTE RD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN.: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 650 LA PORTE RD - 2-18-25 FOR BILLING INQUIRY: (319)291-4323 [ Description INSPECTION 20,000 OCCUPANCY FEE Total Price ] $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 12606 02/25/2025 03/30/2025 2025-00000277 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT CADILLAC LANES, 650 LA PORTE RD, BLDG 6S0 LA PORTE RD, WATERLOO /A S0702 DETAILS Inspection Date: 02/18/2025 I Inspection Type: Annual Inspection (1Yr) ; Inspection Number: 12357 Shift: N/A 3 Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A I Fee: $100.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 31 I Violations: 12 I N/A Codes: 34 STATUS CODE DESCRIPTION FAIL 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Location: South exit corridor Original Comment: remove all storage and obstructions. FAIL 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Location: North exit cooridor Original Comment: remove all storage from exit path. Printed on 02/18/2025 @ 10:33 Page 1 of 5 STATUS CODE DESCRIPTION FAIL 1032.3 - Obstructions. A means of egress shall be free from obstructions that would prevent its use, including the accumulation of snow and ice. Location: Exit door in lazer tag area Original Comment: Door will not open. Has snow piled against it. remove snow at all times. FAIL 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in illumination. accordance with Sections 1008.3 and 1104.5.1. Location: Lounge seating area Original Comment: repair egress light. Not 1 foot candle and will not last 90 minutes. FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Above lounge side exit door Original Comment: repair exit light FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: In basement by back hall Original Comment: repair exit/egress light. Printed on 02/18/2025 @ 10:33 Page 2 of 5 STATUS CODE DESCRIPTION FAIL FAIL 1203.4.3 - Records. Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. 5303.5.3 - Securing compressed gas containers, cylinders and tanks. 603.2.2 - Unapproved conditionsOpen electrical terminations. Location: High ceiling area of lazer tag Original Comment: Test all exit and egress lights in lazer high ceiling and back wall areas and provide signature and date that all are working properly . Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Location: Kitchen office Original Comment: Secure tall compressed gas cylinders with CHAIN or other approved tip over prevention device. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: arcade area ceiling for disco light Original Comment: replace missing outlet cover. Printed on 02/18/2025 @ 10:33 Page 3 of 5 STATUS CODE DESCRIPTION FAIL 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Behind arcade desk Original Comment: remove extension cord from walkway. Power strip may be utilized for computer equipment. Protect power cord with listed cord protector. FAIL 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Speaker by main exit Original Comment: remove extension cord. FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. GENERAL NOTES Location: kitchen hood exhaust system cleaning inspection report. Original Comment: Provide documentation of current semi-annual kitchen hood exhaust system cleaning inspection report with all discrepancies corrected. Currently 25 days past due. Contractor must upload online to the compliance engine. Printed on 02/18/2025 @ 10:33 Page 4 of 5 JEFF SIEBEL - 02/18/2025 @ 10:23 JEFF SIEBEL - 02/18/2025 @ 10:29 JEFF SIEBEL - 02/18/2025 @ 10:30 REINSPECTION DATE 03/14/2025 CONTACT SIGNATURE Mick Hackbarth Signed on: 02/18/2025 @ 10:31 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 02/18/2025 @ 10:31 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Annual inspection $100 Kitchen hood fire suppressioni inspection due 4/7/25 Dryer vent cleaned by Drew Lubka on 2/25 Printed on 02/18/2025 @ 10:33 Page 5 of 5